The joint influence of albedo and insulation on roof performance: An observational study

•Spatial (vertical) and temporal variation in heat flux observed over multiple roofs.•Albedo plays a dominant role in reducing the heat transfer in summer months.•Doubling insulation thickness halves heat transfer in winter months.•Wintertime penalty of white roofs negligible compared to summer savi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 2015-04, Vol.93 (C), p.249-258
Hauptverfasser: Ramamurthy, P., Sun, T., Rule, K., Bou-Zeid, E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 258
container_issue C
container_start_page 249
container_title Energy and buildings
container_volume 93
creator Ramamurthy, P.
Sun, T.
Rule, K.
Bou-Zeid, E.
description •Spatial (vertical) and temporal variation in heat flux observed over multiple roofs.•Albedo plays a dominant role in reducing the heat transfer in summer months.•Doubling insulation thickness halves heat transfer in winter months.•Wintertime penalty of white roofs negligible compared to summer savings.•White roofs with high R-values recommended for north eastern U.S. This article focuses on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. Our analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10°C and 45°C during summer months compared to black membranes that ranged between 10°C and 80°C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. This has important implications for determining the peak heating and cooling times.
doi_str_mv 10.1016/j.enbuild.2015.02.040
format Article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1254734</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378778815001450</els_id><sourcerecordid>S0378778815001450</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-689c6edf9e11fa369b3ef9a98d1b5537164799f8965b2f218a3e02814ca785473</originalsourceid><addsrcrecordid>eNqFkE1rAyEQhj200DTtTyhI77tV90t7KSH0CwK9pNCbuDoSl80adDeQf1-3yb0wMDA-8w4-CD1QklNC66cuh6GdXG9yRmiVE5aTklyhBSkanjUN5zfoNsaOEFJXDV2gn-0OcOfdMGI32H6CQQP2Fqu-BeOxGkyax6lXo_MDThV8ej1AsD7sVYKf8SrN2wjh-MeoHsdxMqc7dG1VH-H-0pfo--11u_7INl_vn-vVJtMlY2NWc6FrMFYApVYVtWgLsEIJbmhbVUVD67IRwnJRVy2zjHJVAGGcllo1vCqbYokez7k-jk5G7UbQO-2HAfQoKZuRMkHVGdLBxxjAykNwexVOkhI5e5OdvHiTszdJmEze0t7LeQ_SD44OwnxgVmRcmPONd_8k_AJmgntg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The joint influence of albedo and insulation on roof performance: An observational study</title><source>Elsevier ScienceDirect Journals</source><creator>Ramamurthy, P. ; Sun, T. ; Rule, K. ; Bou-Zeid, E.</creator><creatorcontrib>Ramamurthy, P. ; Sun, T. ; Rule, K. ; Bou-Zeid, E. ; Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)</creatorcontrib><description>•Spatial (vertical) and temporal variation in heat flux observed over multiple roofs.•Albedo plays a dominant role in reducing the heat transfer in summer months.•Doubling insulation thickness halves heat transfer in winter months.•Wintertime penalty of white roofs negligible compared to summer savings.•White roofs with high R-values recommended for north eastern U.S. This article focuses on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. Our analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10°C and 45°C during summer months compared to black membranes that ranged between 10°C and 80°C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. This has important implications for determining the peak heating and cooling times.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/j.enbuild.2015.02.040</identifier><language>eng</language><publisher>United States: Elsevier B.V</publisher><subject>Cool roof ; ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION ; Roof albedo ; Roof heat flux ; Roof insulation</subject><ispartof>Energy and buildings, 2015-04, Vol.93 (C), p.249-258</ispartof><rights>2015 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-689c6edf9e11fa369b3ef9a98d1b5537164799f8965b2f218a3e02814ca785473</citedby><cites>FETCH-LOGICAL-c422t-689c6edf9e11fa369b3ef9a98d1b5537164799f8965b2f218a3e02814ca785473</cites><orcidid>0000000242977448</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0378778815001450$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.osti.gov/servlets/purl/1254734$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Ramamurthy, P.</creatorcontrib><creatorcontrib>Sun, T.</creatorcontrib><creatorcontrib>Rule, K.</creatorcontrib><creatorcontrib>Bou-Zeid, E.</creatorcontrib><creatorcontrib>Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)</creatorcontrib><title>The joint influence of albedo and insulation on roof performance: An observational study</title><title>Energy and buildings</title><description>•Spatial (vertical) and temporal variation in heat flux observed over multiple roofs.•Albedo plays a dominant role in reducing the heat transfer in summer months.•Doubling insulation thickness halves heat transfer in winter months.•Wintertime penalty of white roofs negligible compared to summer savings.•White roofs with high R-values recommended for north eastern U.S. This article focuses on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. Our analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10°C and 45°C during summer months compared to black membranes that ranged between 10°C and 80°C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. This has important implications for determining the peak heating and cooling times.</description><subject>Cool roof</subject><subject>ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION</subject><subject>Roof albedo</subject><subject>Roof heat flux</subject><subject>Roof insulation</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqFkE1rAyEQhj200DTtTyhI77tV90t7KSH0CwK9pNCbuDoSl80adDeQf1-3yb0wMDA-8w4-CD1QklNC66cuh6GdXG9yRmiVE5aTklyhBSkanjUN5zfoNsaOEFJXDV2gn-0OcOfdMGI32H6CQQP2Fqu-BeOxGkyax6lXo_MDThV8ej1AsD7sVYKf8SrN2wjh-MeoHsdxMqc7dG1VH-H-0pfo--11u_7INl_vn-vVJtMlY2NWc6FrMFYApVYVtWgLsEIJbmhbVUVD67IRwnJRVy2zjHJVAGGcllo1vCqbYokez7k-jk5G7UbQO-2HAfQoKZuRMkHVGdLBxxjAykNwexVOkhI5e5OdvHiTszdJmEze0t7LeQ_SD44OwnxgVmRcmPONd_8k_AJmgntg</recordid><startdate>20150415</startdate><enddate>20150415</enddate><creator>Ramamurthy, P.</creator><creator>Sun, T.</creator><creator>Rule, K.</creator><creator>Bou-Zeid, E.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OIOZB</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000000242977448</orcidid></search><sort><creationdate>20150415</creationdate><title>The joint influence of albedo and insulation on roof performance: An observational study</title><author>Ramamurthy, P. ; Sun, T. ; Rule, K. ; Bou-Zeid, E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-689c6edf9e11fa369b3ef9a98d1b5537164799f8965b2f218a3e02814ca785473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Cool roof</topic><topic>ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION</topic><topic>Roof albedo</topic><topic>Roof heat flux</topic><topic>Roof insulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramamurthy, P.</creatorcontrib><creatorcontrib>Sun, T.</creatorcontrib><creatorcontrib>Rule, K.</creatorcontrib><creatorcontrib>Bou-Zeid, E.</creatorcontrib><creatorcontrib>Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramamurthy, P.</au><au>Sun, T.</au><au>Rule, K.</au><au>Bou-Zeid, E.</au><aucorp>Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The joint influence of albedo and insulation on roof performance: An observational study</atitle><jtitle>Energy and buildings</jtitle><date>2015-04-15</date><risdate>2015</risdate><volume>93</volume><issue>C</issue><spage>249</spage><epage>258</epage><pages>249-258</pages><issn>0378-7788</issn><abstract>•Spatial (vertical) and temporal variation in heat flux observed over multiple roofs.•Albedo plays a dominant role in reducing the heat transfer in summer months.•Doubling insulation thickness halves heat transfer in winter months.•Wintertime penalty of white roofs negligible compared to summer savings.•White roofs with high R-values recommended for north eastern U.S. This article focuses on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. Our analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10°C and 45°C during summer months compared to black membranes that ranged between 10°C and 80°C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. This has important implications for determining the peak heating and cooling times.</abstract><cop>United States</cop><pub>Elsevier B.V</pub><doi>10.1016/j.enbuild.2015.02.040</doi><tpages>10</tpages><orcidid>https://orcid.org/0000000242977448</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0378-7788
ispartof Energy and buildings, 2015-04, Vol.93 (C), p.249-258
issn 0378-7788
language eng
recordid cdi_osti_scitechconnect_1254734
source Elsevier ScienceDirect Journals
subjects Cool roof
ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
Roof albedo
Roof heat flux
Roof insulation
title The joint influence of albedo and insulation on roof performance: An observational study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T17%3A14%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20joint%20influence%20of%20albedo%20and%20insulation%20on%20roof%20performance:%20An%20observational%20study&rft.jtitle=Energy%20and%20buildings&rft.au=Ramamurthy,%20P.&rft.aucorp=Princeton%20Plasma%20Physics%20Lab.%20(PPPL),%20Princeton,%20NJ%20(United%20States)&rft.date=2015-04-15&rft.volume=93&rft.issue=C&rft.spage=249&rft.epage=258&rft.pages=249-258&rft.issn=0378-7788&rft_id=info:doi/10.1016/j.enbuild.2015.02.040&rft_dat=%3Celsevier_osti_%3ES0378778815001450%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0378778815001450&rfr_iscdi=true