Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung
X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Buch |
Sprache: | ger |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Schröter, Tobias Jörg |
description | X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to a few centimeters in the diagonal (e.g. 10 cm). In this work possibilities to enlarge the area of X-ray gratings, as they are required for the Talbot-Lau Interferometry, were developed and analyzed. |
doi_str_mv | 10.5445/KSP/1000075852 |
format | Book |
fullrecord | <record><control><sourceid>oapen</sourceid><recordid>TN_cdi_oapen_doabooks_61953</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>61953</sourcerecordid><originalsourceid>FETCH-LOGICAL-o1416-4d40b031f42e70771f0d268ea55d9cc412695dc714f828f690a86f771bd515a43</originalsourceid><addsrcrecordid>eNotTEtOwzAUtARIlNItGza5QKhf_Im9LBUURCUqCmyLEz8nIZGD4iKOwy26YpeLkQhmMTPSfAi5AHolOBfzh-1mDnRAKpRIjsgZSxkIOtIxmYCSOhag2CmZhfA-1BKlNaN0Qt5esSu6_tB_Y_fpi8hiiLZYOmxGZ7GLnvqD3xfo401pAvq69fvOhH18XTW2wGwcuf6ni2yFUd1Uvgp5idHCf6G3Q3hOTpxpAs7-dUpebm-el3fx-nF1v1ys4xY4yJhbTjPKwPEEU5qm4KhNpEIjhNV5ziGRWtg8Be5UopzU1Cjphl5mBQjD2ZRc_v225gP9zrYma9s67CRowdgv8glXWA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>book</recordtype></control><display><type>book</type><title>Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung</title><source>DOAB: Directory of Open Access Books</source><creator>Schröter, Tobias Jörg</creator><creatorcontrib>Schröter, Tobias Jörg</creatorcontrib><description>X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to a few centimeters in the diagonal (e.g. 10 cm). In this work possibilities to enlarge the area of X-ray gratings, as they are required for the Talbot-Lau Interferometry, were developed and analyzed.</description><identifier>ISSN: 1869-5183</identifier><identifier>ISBN: 3731507315</identifier><identifier>ISBN: 9783731507314</identifier><identifier>DOI: 10.5445/KSP/1000075852</identifier><language>ger</language><publisher>KIT Scientific Publishing</publisher><subject>Book Industry Communication ; Kacheln ; LIGA-Technik ; LIGA-technology ; Röntgenbildgebung ; Röntgengitter ; Talbot-Lau Interferometrie ; Talbot-Lau Interferometry ; Technology, engineering, agriculture ; Technology: general issues ; tiling ; X-ray gratings ; X-ray imaging</subject><creationdate>2017</creationdate><tpages>XII, 185</tpages><format>XII, 185</format><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><relation>Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik</relation></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>306,780,784,786,27925,55310</link.rule.ids></links><search><creatorcontrib>Schröter, Tobias Jörg</creatorcontrib><title>Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung</title><description>X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to a few centimeters in the diagonal (e.g. 10 cm). In this work possibilities to enlarge the area of X-ray gratings, as they are required for the Talbot-Lau Interferometry, were developed and analyzed.</description><subject>Book Industry Communication</subject><subject>Kacheln</subject><subject>LIGA-Technik</subject><subject>LIGA-technology</subject><subject>Röntgenbildgebung</subject><subject>Röntgengitter</subject><subject>Talbot-Lau Interferometrie</subject><subject>Talbot-Lau Interferometry</subject><subject>Technology, engineering, agriculture</subject><subject>Technology: general issues</subject><subject>tiling</subject><subject>X-ray gratings</subject><subject>X-ray imaging</subject><issn>1869-5183</issn><isbn>3731507315</isbn><isbn>9783731507314</isbn><fulltext>true</fulltext><rsrctype>book</rsrctype><creationdate>2017</creationdate><recordtype>book</recordtype><sourceid>V1H</sourceid><recordid>eNotTEtOwzAUtARIlNItGza5QKhf_Im9LBUURCUqCmyLEz8nIZGD4iKOwy26YpeLkQhmMTPSfAi5AHolOBfzh-1mDnRAKpRIjsgZSxkIOtIxmYCSOhag2CmZhfA-1BKlNaN0Qt5esSu6_tB_Y_fpi8hiiLZYOmxGZ7GLnvqD3xfo401pAvq69fvOhH18XTW2wGwcuf6ni2yFUd1Uvgp5idHCf6G3Q3hOTpxpAs7-dUpebm-el3fx-nF1v1ys4xY4yJhbTjPKwPEEU5qm4KhNpEIjhNV5ziGRWtg8Be5UopzU1Cjphl5mBQjD2ZRc_v225gP9zrYma9s67CRowdgv8glXWA</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Schröter, Tobias Jörg</creator><general>KIT Scientific Publishing</general><scope>V1H</scope></search><sort><creationdate>2017</creationdate><title>Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung</title><author>Schröter, Tobias Jörg</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o1416-4d40b031f42e70771f0d268ea55d9cc412695dc714f828f690a86f771bd515a43</frbrgroupid><rsrctype>books</rsrctype><prefilter>books</prefilter><language>ger</language><creationdate>2017</creationdate><topic>Book Industry Communication</topic><topic>Kacheln</topic><topic>LIGA-Technik</topic><topic>LIGA-technology</topic><topic>Röntgenbildgebung</topic><topic>Röntgengitter</topic><topic>Talbot-Lau Interferometrie</topic><topic>Talbot-Lau Interferometry</topic><topic>Technology, engineering, agriculture</topic><topic>Technology: general issues</topic><topic>tiling</topic><topic>X-ray gratings</topic><topic>X-ray imaging</topic><toplevel>online_resources</toplevel><creatorcontrib>Schröter, Tobias Jörg</creatorcontrib><collection>DOAB: Directory of Open Access Books</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schröter, Tobias Jörg</au><format>book</format><genre>book</genre><ristype>BOOK</ristype><btitle>Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung</btitle><seriestitle>Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik</seriestitle><date>2017</date><risdate>2017</risdate><issn>1869-5183</issn><isbn>3731507315</isbn><isbn>9783731507314</isbn><abstract>X-ray phase contrast imaging is a highly promising technology for the clinical diagnostic. Particularly high demands are placed on the required X-ray gratings, as the core element of this method. Such gratings can be fabricated using LIGA-technology, where the structured area is currently limited to a few centimeters in the diagonal (e.g. 10 cm). In this work possibilities to enlarge the area of X-ray gratings, as they are required for the Talbot-Lau Interferometry, were developed and analyzed.</abstract><pub>KIT Scientific Publishing</pub><doi>10.5445/KSP/1000075852</doi><tpages>XII, 185</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1869-5183 |
ispartof | |
issn | 1869-5183 |
language | ger |
recordid | cdi_oapen_doabooks_61953 |
source | DOAB: Directory of Open Access Books |
subjects | Book Industry Communication Kacheln LIGA-Technik LIGA-technology Röntgenbildgebung Röntgengitter Talbot-Lau Interferometrie Talbot-Lau Interferometry Technology, engineering, agriculture Technology: general issues tiling X-ray gratings X-ray imaging |
title | Vergrößerung des Sehfeldes der Röntgen-Phasenkontrast-Bildgebung für die klinische Anwendung |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T20%3A53%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-oapen&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=book&rft.btitle=Vergr%C3%B6%C3%9Ferung%20des%20Sehfeldes%20der%20R%C3%B6ntgen-Phasenkontrast-Bildgebung%20f%C3%BCr%20die%20klinische%20Anwendung&rft.au=Schr%C3%B6ter,%20Tobias%20J%C3%B6rg&rft.date=2017&rft.issn=1869-5183&rft.isbn=3731507315&rft.isbn_list=9783731507314&rft_id=info:doi/10.5445/KSP/1000075852&rft_dat=%3Coapen%3E61953%3C/oapen%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |