수직-수평 팬 배치에 따른 라디에이터 냉각 효과 분석

In this study, the effect of radiator cooling according to the vertical–horizontal fan arrangement and fan performance was analyzed. Computational results and experimental data were compared to prove the validity of the computational fluid dynamics analysis method used in the study. The heat dissipa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:한국생산제조학회지 2021, 30(6), , pp.487-494
Hauptverfasser: 윤장혁(Jang-Hyeok Yun), 이재철(Jae-Chul Lee), 강태원(Tae-Won Kang), 이민재(Min-Jae Lee), 전종수(Jong-Su Jeon), 양현익(Hyun-Ik Yang)
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, the effect of radiator cooling according to the vertical–horizontal fan arrangement and fan performance was analyzed. Computational results and experimental data were compared to prove the validity of the computational fluid dynamics analysis method used in the study. The heat dissipation was affected by the collision effect of the fluid flows from the cooling fans. The newly created flows from the collision of the fluid flows occurred most in the S2B1 layout, and thus, the largest heat dissipation occurred in the S2B1 layout. The cooling efficiency was reviewed using the FOM formula. When the fan model was included in the S2B1 layout, the heat dissipation reduced by 5.38% compared to the conventional layout, but the cooling efficiency increased by 32.18%. As a result, the newly proposed S2B1 layout exhibited an improved cooling performance and efficiency. KCI Citation Count: 0
ISSN:2508-5093
2508-5107
DOI:10.7735/ksmte.2021.30.6.487