Personalized Urination Activity Management Based on an Intelligent System Using a Wearable Device
Purpose: In this study, a urinary management system was established to collect and analyze urinary time and interval data detected through patient-worn smart bands, and the results of the analysis were shown through a web-based visualization to enable monitoring and appropriate feedback for urologic...
Gespeichert in:
Veröffentlicht in: | International neurourology journal 2021, 25(3), , pp.229-235 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: In this study, a urinary management system was established to collect and analyze urinary time and interval data detected through patient-worn smart bands, and the results of the analysis were shown through a web-based visualization to enable monitoring and appropriate feedback for urological patients. Methods: We designed a device that can recognize urination time and spacing based on patient-specific posture and consistent posture changes, and we built a urination patient management system based on this device. The order of body movements during urination was consistent in terms of time characteristics; therefore, sequential data were analyzed and urinary activity was recognized using repeated neural networks and long-term short-term memory systems. The results were implemented as a web (HTML5) service program, enabling visual support for clinical diagnostic assistance. Results: Experiments were conducted to evaluate the performance of the proposed recognition techniques. The effectiveness of smart band monitoring urination was evaluated in 30 men (average age, 28.73 years; range, 26-34 years) without urination problems. The entire experiment lasted a total of 3 days. The final accuracy of the algorithm was calculated based on urological clinical guidelines. This experiment showed a high average accuracy of 95.8%, demonstrating the soundness of the proposed algorithm. Conclusions: This urinary activity management system showed high accuracy and was applied in a clinical environment to characterize patients' urinary patterns. As wearable devices are developed and generalized, algorithms capable of detecting certain sequential body motor patterns that reflect certain physiological behaviors can be a new methodology for studying human physiological behaviors. It is also thought that these systems will have a significant impact on diagnostic assistance for clinicians. |
---|---|
ISSN: | 2093-4777 2093-6931 2093-6931 |
DOI: | 10.5213/inj.2142276.138 |