Biomechanical Properties of the Cranial Dura Mater with Puncture Defects : An In Vitro Study
The primary aim of this investigation was to explore the nature of dura mater biomechanics following the introduction of puncture defect(s). Twenty-eight dura mater specimens were collected during autopsy from the department of forensic medicine of the authors' institution. Specimens were divid...
Gespeichert in:
Veröffentlicht in: | Journal of Korean Neurosurgical Society 2019, 62(4), , pp.382-388 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The primary aim of this investigation was to explore the nature of dura mater biomechanics following the introduction of puncture defect(s).
Twenty-eight dura mater specimens were collected during autopsy from the department of forensic medicine of the authors' institution. Specimens were divided randomly into one of four groups : group I (cranial dura mater; n=7), group II (cranial dura mater with one puncture defect; n=7); group III (cranial dura mater with two puncture defects; n=7), and group IV (cranial dura mater with three puncture defects; n=7).
The mean±standard deviation tensile strengths of the dura mater were 8.35±3.16, 8.22±3.32, 7.13±1.77, and 6.94±1.93 MPa for groups I, II, III, and IV, respectively. There was no statistical difference between all groups. A single, two or more punctures of the dura mater using a 20-gauge Quincke needle did not affect cranial dura tensile strength.
This biomechanical study may contribute to the future development of artificial dura mater substitutes and medical needles that have a lower negative impact on the biomechanical properties of dura mater. |
---|---|
ISSN: | 2005-3711 1598-7876 |
DOI: | 10.3340/jkns.2018.0130 |