Fast Interlock System for Machine Protection in PLS-II
We overview the system design of the Pohang Light Source-II (PLS-II), and demonstrate that synchrotron radiation is the cause of a recent incident that damaged the vacuum components. To preclude further incidents, we designed a system that shuts off the beam if such damage is imminent. We used an AN...
Gespeichert in:
Veröffentlicht in: | Journal of the Korean Physical Society 2020, 76(4), , pp.301-305 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We overview the system design of the Pohang Light Source-II (PLS-II), and demonstrate that synchrotron radiation is the cause of a recent incident that damaged the vacuum components. To preclude further incidents, we designed a system that shuts off the beam if such damage is imminent. We used an ANSYS simulation to estimate the appropriate time allowed for this shut-off then. A Fast Interlock System is implemented to accomplish beam shut-off within this time. In bench test, this system shut down the beam within the acceptable time. The installation and the operation of the Fast Interlock System in PLS-II is planned. |
---|---|