Influences of Pump Spot Radius and Depth of Focus on the Thermal Effect of Tm:YAP Crystal

The thermal effect and the light output of a laser crystal under different pumping depths were reported., Based on the thermal model of a single-ended pumped Tm:YAP crystal, the thermal stress coupled model used Comsol to theoretically calculate the effect of changing the pump spot size and pump dep...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Current optics and photonics 2019, 3(5), , pp.458-465
Hauptverfasser: Zhang, Hongliang, Wen, Ya, Zhang, Lin, Fan, Zhen, Liu, Jinge, Wu, Chunting
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The thermal effect and the light output of a laser crystal under different pumping depths were reported., Based on the thermal model of a single-ended pumped Tm:YAP crystal, the thermal stress coupled model used Comsol to theoretically calculate the effect of changing the pump spot size and pump depth on crystal heat distribution and stress distribution. The experimental results showed that the laser output power first increased and then decreased with increasing pump spot size. As the depth of focus increased, the laser output power first increased and then decreased. The experimental results were consistent with the theoretical simulation results. The theory of pump spot radius and depth of focus in this paper provided an effective simulation method for mitigating thermal effects, and provided theoretical supports for laser crystals to obtain higher laser output power.
ISSN:2508-7266
2508-7274
DOI:10.3807/COPP.2019.3.5.458