Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Meginnis, Ian M., Norcross, Jason, Bekdash, Omar, Ploutz-Snyder, Robert
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Meginnis, Ian M.
Norcross, Jason
Bekdash, Omar
Ploutz-Snyder, Robert
description A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.
format Conference Proceeding
fullrecord <record><control><sourceid>nasa_CYI</sourceid><recordid>TN_cdi_nasa_ntrs_20160003082</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20160003082</sourcerecordid><originalsourceid>FETCH-nasa_ntrs_201600030823</originalsourceid><addsrcrecordid>eNqFybEKwjAQgOEsDqK-gcO9QCG2IO5RMUOnFlyEcsYrOdREkwuIT6-Du9P_wT9VJ-MxoRNK_EbhGCCOYDCdv9pyfPGF4IjZxyLQEuaS6E5BoCfnAz8LZeAA4glaTNfKWgvdAx1BV1jmajLiLdPi15la7ne9OVQBMw5BUh5qvVprrRu9qZs_-wPwyza-</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit</title><source>NASA Technical Reports Server</source><creator>Meginnis, Ian M. ; Norcross, Jason ; Bekdash, Omar ; Ploutz-Snyder, Robert</creator><creatorcontrib>Meginnis, Ian M. ; Norcross, Jason ; Bekdash, Omar ; Ploutz-Snyder, Robert</creatorcontrib><description>A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.</description><language>eng</language><publisher>Johnson Space Center</publisher><subject>Man/System Technology And Life Support</subject><creationdate>2016</creationdate><rights>Copyright Determination: PUBLIC_USE_PERMITTED</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,780,800</link.rule.ids><linktorsrc>$$Uhttps://ntrs.nasa.gov/citations/20160003082$$EView_record_in_NASA$$FView_record_in_$$GNASA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Meginnis, Ian M.</creatorcontrib><creatorcontrib>Norcross, Jason</creatorcontrib><creatorcontrib>Bekdash, Omar</creatorcontrib><creatorcontrib>Ploutz-Snyder, Robert</creatorcontrib><title>Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit</title><description>A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.</description><subject>Man/System Technology And Life Support</subject><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2016</creationdate><recordtype>conference_proceeding</recordtype><sourceid>CYI</sourceid><recordid>eNqFybEKwjAQgOEsDqK-gcO9QCG2IO5RMUOnFlyEcsYrOdREkwuIT6-Du9P_wT9VJ-MxoRNK_EbhGCCOYDCdv9pyfPGF4IjZxyLQEuaS6E5BoCfnAz8LZeAA4glaTNfKWgvdAx1BV1jmajLiLdPi15la7ne9OVQBMw5BUh5qvVprrRu9qZs_-wPwyza-</recordid><startdate>20160710</startdate><enddate>20160710</enddate><creator>Meginnis, Ian M.</creator><creator>Norcross, Jason</creator><creator>Bekdash, Omar</creator><creator>Ploutz-Snyder, Robert</creator><scope>CYE</scope><scope>CYI</scope></search><sort><creationdate>20160710</creationdate><title>Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit</title><author>Meginnis, Ian M. ; Norcross, Jason ; Bekdash, Omar ; Ploutz-Snyder, Robert</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-nasa_ntrs_201600030823</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Man/System Technology And Life Support</topic><toplevel>online_resources</toplevel><creatorcontrib>Meginnis, Ian M.</creatorcontrib><creatorcontrib>Norcross, Jason</creatorcontrib><creatorcontrib>Bekdash, Omar</creatorcontrib><creatorcontrib>Ploutz-Snyder, Robert</creatorcontrib><collection>NASA Scientific and Technical Information</collection><collection>NASA Technical Reports Server</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Meginnis, Ian M.</au><au>Norcross, Jason</au><au>Bekdash, Omar</au><au>Ploutz-Snyder, Robert</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit</atitle><date>2016-07-10</date><risdate>2016</risdate><abstract>A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.</abstract><cop>Johnson Space Center</cop><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_nasa_ntrs_20160003082
source NASA Technical Reports Server
subjects Man/System Technology And Life Support
title Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T03%3A07%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-nasa_CYI&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Characterization%20of%20Carbon%20Dioxide%20Washout%20Measurement%20Techniques%20in%20the%20Mark-III%20Space%20Suit&rft.au=Meginnis,%20Ian%20M.&rft.date=2016-07-10&rft_id=info:doi/&rft_dat=%3Cnasa_CYI%3E20160003082%3C/nasa_CYI%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true