Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 & 3, and associated support equipment, which were tested in the Radi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dugala, Gina M., Taylor, Linda M., Bell, Mark E., Dolce, James L., Fraeman, Martin, Frankford, David P.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Dugala, Gina M.
Taylor, Linda M.
Bell, Mark E.
Dolce, James L.
Fraeman, Martin
Frankford, David P.
description NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 & 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.
format Conference Proceeding
fullrecord <record><control><sourceid>nasa_CYI</sourceid><recordid>TN_cdi_nasa_ntrs_20150021861</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20150021861</sourcerecordid><originalsourceid>FETCH-nasa_ntrs_201500218613</originalsourceid><addsrcrecordid>eNqFjj0KwkAQhdNYiHoDi7mAkEQU2xB_QUSMvYzJmCysM7I7RjyLl3UFCzur9x7fV7xu9MqqFrmkCgo1zhquIRduyak4mN_R_szQ1Im15OBIXj8uKuyyIoOVJWY4kCd0ZQM5sQbLMGhDcMDKiPGiciPYyyOQ4umVrv6bsAl67VCNMGzxLKGKe_ajzgWtp8E3e9FwuTjm6xGjx1P44k9pnEziOE1m02T8B78BqVpO4w</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory</title><source>NASA Technical Reports Server</source><creator>Dugala, Gina M. ; Taylor, Linda M. ; Bell, Mark E. ; Dolce, James L. ; Fraeman, Martin ; Frankford, David P.</creator><creatorcontrib>Dugala, Gina M. ; Taylor, Linda M. ; Bell, Mark E. ; Dolce, James L. ; Fraeman, Martin ; Frankford, David P.</creatorcontrib><description>NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 &amp; 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.</description><language>eng</language><publisher>Glenn Research Center</publisher><subject>Energy Production And Conversion ; Nuclear Physics ; Spacecraft Propulsion And Power</subject><creationdate>2015</creationdate><rights>Copyright Determination: PUBLIC_USE_PERMITTED</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,780,800</link.rule.ids><linktorsrc>$$Uhttps://ntrs.nasa.gov/citations/20150021861$$EView_record_in_NASA$$FView_record_in_$$GNASA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Dugala, Gina M.</creatorcontrib><creatorcontrib>Taylor, Linda M.</creatorcontrib><creatorcontrib>Bell, Mark E.</creatorcontrib><creatorcontrib>Dolce, James L.</creatorcontrib><creatorcontrib>Fraeman, Martin</creatorcontrib><creatorcontrib>Frankford, David P.</creatorcontrib><title>Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory</title><description>NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 &amp; 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.</description><subject>Energy Production And Conversion</subject><subject>Nuclear Physics</subject><subject>Spacecraft Propulsion And Power</subject><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2015</creationdate><recordtype>conference_proceeding</recordtype><sourceid>CYI</sourceid><recordid>eNqFjj0KwkAQhdNYiHoDi7mAkEQU2xB_QUSMvYzJmCysM7I7RjyLl3UFCzur9x7fV7xu9MqqFrmkCgo1zhquIRduyak4mN_R_szQ1Im15OBIXj8uKuyyIoOVJWY4kCd0ZQM5sQbLMGhDcMDKiPGiciPYyyOQ4umVrv6bsAl67VCNMGzxLKGKe_ajzgWtp8E3e9FwuTjm6xGjx1P44k9pnEziOE1m02T8B78BqVpO4w</recordid><startdate>20150727</startdate><enddate>20150727</enddate><creator>Dugala, Gina M.</creator><creator>Taylor, Linda M.</creator><creator>Bell, Mark E.</creator><creator>Dolce, James L.</creator><creator>Fraeman, Martin</creator><creator>Frankford, David P.</creator><scope>CYE</scope><scope>CYI</scope></search><sort><creationdate>20150727</creationdate><title>Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory</title><author>Dugala, Gina M. ; Taylor, Linda M. ; Bell, Mark E. ; Dolce, James L. ; Fraeman, Martin ; Frankford, David P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-nasa_ntrs_201500218613</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Energy Production And Conversion</topic><topic>Nuclear Physics</topic><topic>Spacecraft Propulsion And Power</topic><toplevel>online_resources</toplevel><creatorcontrib>Dugala, Gina M.</creatorcontrib><creatorcontrib>Taylor, Linda M.</creatorcontrib><creatorcontrib>Bell, Mark E.</creatorcontrib><creatorcontrib>Dolce, James L.</creatorcontrib><creatorcontrib>Fraeman, Martin</creatorcontrib><creatorcontrib>Frankford, David P.</creatorcontrib><collection>NASA Scientific and Technical Information</collection><collection>NASA Technical Reports Server</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Dugala, Gina M.</au><au>Taylor, Linda M.</au><au>Bell, Mark E.</au><au>Dolce, James L.</au><au>Fraeman, Martin</au><au>Frankford, David P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory</atitle><date>2015-07-27</date><risdate>2015</risdate><abstract>NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 &amp; 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.</abstract><cop>Glenn Research Center</cop><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_nasa_ntrs_20150021861
source NASA Technical Reports Server
subjects Energy Production And Conversion
Nuclear Physics
Spacecraft Propulsion And Power
title Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T09%3A55%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-nasa_CYI&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Advanced%20Stirling%20Convertor%20Dual%20Convertor%20Controller%20Testing%20at%20NASA%20Glenn%20Research%20Center%20in%20the%20Radioisotope%20Power%20Systems%20System%20Integration%20Laboratory&rft.au=Dugala,%20Gina%20M.&rft.date=2015-07-27&rft_id=info:doi/&rft_dat=%3Cnasa_CYI%3E20150021861%3C/nasa_CYI%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true