VETA-1 x ray detection system
The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Podgorski, W. A. Flanagan, Kathy A. Freeman, Mark D. Goddard, R. G. Kellogg, Edwin M. Norton, T. J. Ouellette, J. P. Roy, A. G. Schwartz, Daniel A. |
description | The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system. |
format | Report |
fullrecord | <record><control><sourceid>nasa_CYI</sourceid><recordid>TN_cdi_nasa_ntrs_19930016996</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19930016996</sourcerecordid><originalsourceid>FETCH-nasa_ntrs_199300169963</originalsourceid><addsrcrecordid>eNrjZJANcw1x1DVUqFAoSqxUSEktSU0uyczPUyiuLC5JzeVhYE1LzClO5YXS3Awybq4hzh66eYnFifF5JUXF8YaWlsYGBoZmlpZmxgSkAeufH1I</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>VETA-1 x ray detection system</title><source>NASA Technical Reports Server</source><creator>Podgorski, W. A. ; Flanagan, Kathy A. ; Freeman, Mark D. ; Goddard, R. G. ; Kellogg, Edwin M. ; Norton, T. J. ; Ouellette, J. P. ; Roy, A. G. ; Schwartz, Daniel A.</creator><creatorcontrib>Podgorski, W. A. ; Flanagan, Kathy A. ; Freeman, Mark D. ; Goddard, R. G. ; Kellogg, Edwin M. ; Norton, T. J. ; Ouellette, J. P. ; Roy, A. G. ; Schwartz, Daniel A.</creatorcontrib><description>The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.</description><language>eng</language><publisher>Legacy CDMS</publisher><subject>Optics</subject><creationdate>1992</creationdate><rights>Copyright Determination: GOV_PUBLIC_USE_PERMITTED</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,800,4490</link.rule.ids><linktorsrc>$$Uhttps://ntrs.nasa.gov/citations/19930016996$$EView_record_in_NASA$$FView_record_in_$$GNASA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Podgorski, W. A.</creatorcontrib><creatorcontrib>Flanagan, Kathy A.</creatorcontrib><creatorcontrib>Freeman, Mark D.</creatorcontrib><creatorcontrib>Goddard, R. G.</creatorcontrib><creatorcontrib>Kellogg, Edwin M.</creatorcontrib><creatorcontrib>Norton, T. J.</creatorcontrib><creatorcontrib>Ouellette, J. P.</creatorcontrib><creatorcontrib>Roy, A. G.</creatorcontrib><creatorcontrib>Schwartz, Daniel A.</creatorcontrib><title>VETA-1 x ray detection system</title><description>The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.</description><subject>Optics</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1992</creationdate><recordtype>report</recordtype><sourceid>CYI</sourceid><recordid>eNrjZJANcw1x1DVUqFAoSqxUSEktSU0uyczPUyiuLC5JzeVhYE1LzClO5YXS3Awybq4hzh66eYnFifF5JUXF8YaWlsYGBoZmlpZmxgSkAeufH1I</recordid><startdate>19921023</startdate><enddate>19921023</enddate><creator>Podgorski, W. A.</creator><creator>Flanagan, Kathy A.</creator><creator>Freeman, Mark D.</creator><creator>Goddard, R. G.</creator><creator>Kellogg, Edwin M.</creator><creator>Norton, T. J.</creator><creator>Ouellette, J. P.</creator><creator>Roy, A. G.</creator><creator>Schwartz, Daniel A.</creator><scope>CYE</scope><scope>CYI</scope></search><sort><creationdate>19921023</creationdate><title>VETA-1 x ray detection system</title><author>Podgorski, W. A. ; Flanagan, Kathy A. ; Freeman, Mark D. ; Goddard, R. G. ; Kellogg, Edwin M. ; Norton, T. J. ; Ouellette, J. P. ; Roy, A. G. ; Schwartz, Daniel A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-nasa_ntrs_199300169963</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Optics</topic><toplevel>online_resources</toplevel><creatorcontrib>Podgorski, W. A.</creatorcontrib><creatorcontrib>Flanagan, Kathy A.</creatorcontrib><creatorcontrib>Freeman, Mark D.</creatorcontrib><creatorcontrib>Goddard, R. G.</creatorcontrib><creatorcontrib>Kellogg, Edwin M.</creatorcontrib><creatorcontrib>Norton, T. J.</creatorcontrib><creatorcontrib>Ouellette, J. P.</creatorcontrib><creatorcontrib>Roy, A. G.</creatorcontrib><creatorcontrib>Schwartz, Daniel A.</creatorcontrib><collection>NASA Scientific and Technical Information</collection><collection>NASA Technical Reports Server</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Podgorski, W. A.</au><au>Flanagan, Kathy A.</au><au>Freeman, Mark D.</au><au>Goddard, R. G.</au><au>Kellogg, Edwin M.</au><au>Norton, T. J.</au><au>Ouellette, J. P.</au><au>Roy, A. G.</au><au>Schwartz, Daniel A.</au><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>VETA-1 x ray detection system</btitle><date>1992-10-23</date><risdate>1992</risdate><abstract>The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.</abstract><cop>Legacy CDMS</cop><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | |
ispartof | |
issn | |
language | eng |
recordid | cdi_nasa_ntrs_19930016996 |
source | NASA Technical Reports Server |
subjects | Optics |
title | VETA-1 x ray detection system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T00%3A32%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-nasa_CYI&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=VETA-1%20x%20ray%20detection%20system&rft.au=Podgorski,%20W.%20A.&rft.date=1992-10-23&rft_id=info:doi/&rft_dat=%3Cnasa_CYI%3E19930016996%3C/nasa_CYI%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |