Calibration of sonic valves for the laminar flow control, leading-edge flight test

Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure wer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Petley, D. H., Alexander, W., Jr, Wright, A. S., Jr, Vallas, M.
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Petley, D. H.
Alexander, W., Jr
Wright, A. S., Jr
Vallas, M.
description Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.
format Report
fullrecord <record><control><sourceid>nasa_CYI</sourceid><recordid>TN_cdi_nasa_ntrs_19850015396</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19850015396</sourcerecordid><originalsourceid>FETCH-nasa_ntrs_198500153963</originalsourceid><addsrcrecordid>eNqFy7EKwkAMgOEuDqK-gUMewEJLqdi5KM7iXmKbuwZiApejvr4d3J3-4ePfFo8ehV8JM5uCBXBTHmFBWcghWII8Ewi-WTFBEPvAaJqTyQmEcGKNJU2RVuI4Z8jkeV9sAorT4dddcbxdn_29VHQc1tmHuru0VVW3TXdu_vAXoggztA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Calibration of sonic valves for the laminar flow control, leading-edge flight test</title><source>NASA Technical Reports Server</source><creator>Petley, D. H. ; Alexander, W., Jr ; Wright, A. S., Jr ; Vallas, M.</creator><creatorcontrib>Petley, D. H. ; Alexander, W., Jr ; Wright, A. S., Jr ; Vallas, M.</creatorcontrib><description>Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.</description><language>eng</language><publisher>Legacy CDMS</publisher><subject>Aerodynamics</subject><creationdate>1985</creationdate><rights>Copyright Determination: GOV_PUBLIC_USE_PERMITTED</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,796</link.rule.ids><linktorsrc>$$Uhttps://ntrs.nasa.gov/citations/19850015396$$EView_record_in_NASA$$FView_record_in_$$GNASA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Petley, D. H.</creatorcontrib><creatorcontrib>Alexander, W., Jr</creatorcontrib><creatorcontrib>Wright, A. S., Jr</creatorcontrib><creatorcontrib>Vallas, M.</creatorcontrib><title>Calibration of sonic valves for the laminar flow control, leading-edge flight test</title><description>Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.</description><subject>Aerodynamics</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1985</creationdate><recordtype>report</recordtype><sourceid>CYI</sourceid><recordid>eNqFy7EKwkAMgOEuDqK-gUMewEJLqdi5KM7iXmKbuwZiApejvr4d3J3-4ePfFo8ehV8JM5uCBXBTHmFBWcghWII8Ewi-WTFBEPvAaJqTyQmEcGKNJU2RVuI4Z8jkeV9sAorT4dddcbxdn_29VHQc1tmHuru0VVW3TXdu_vAXoggztA</recordid><startdate>19850501</startdate><enddate>19850501</enddate><creator>Petley, D. H.</creator><creator>Alexander, W., Jr</creator><creator>Wright, A. S., Jr</creator><creator>Vallas, M.</creator><scope>CYE</scope><scope>CYI</scope></search><sort><creationdate>19850501</creationdate><title>Calibration of sonic valves for the laminar flow control, leading-edge flight test</title><author>Petley, D. H. ; Alexander, W., Jr ; Wright, A. S., Jr ; Vallas, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-nasa_ntrs_198500153963</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1985</creationdate><topic>Aerodynamics</topic><toplevel>online_resources</toplevel><creatorcontrib>Petley, D. H.</creatorcontrib><creatorcontrib>Alexander, W., Jr</creatorcontrib><creatorcontrib>Wright, A. S., Jr</creatorcontrib><creatorcontrib>Vallas, M.</creatorcontrib><collection>NASA Scientific and Technical Information</collection><collection>NASA Technical Reports Server</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Petley, D. H.</au><au>Alexander, W., Jr</au><au>Wright, A. S., Jr</au><au>Vallas, M.</au><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Calibration of sonic valves for the laminar flow control, leading-edge flight test</btitle><date>1985-05-01</date><risdate>1985</risdate><abstract>Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.</abstract><cop>Legacy CDMS</cop><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_nasa_ntrs_19850015396
source NASA Technical Reports Server
subjects Aerodynamics
title Calibration of sonic valves for the laminar flow control, leading-edge flight test
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T21%3A12%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-nasa_CYI&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Calibration%20of%20sonic%20valves%20for%20the%20laminar%20flow%20control,%20leading-edge%20flight%20test&rft.au=Petley,%20D.%20H.&rft.date=1985-05-01&rft_id=info:doi/&rft_dat=%3Cnasa_CYI%3E19850015396%3C/nasa_CYI%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true