배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과

목적: 원형전낭절개에 의해 후낭 내에 안전하게 삽입된 single-piece acryl 인공수정체(AcrySof(R), SA60AT, Alcon)의 임상 결과를 three-piece acryl 인공수정체(AcrySof(R), MA60BM, Alcon)와 비교하여 알아보고자 하였다. 대상과 방법: 30안의 SA60AT 삽입군과 30안의 MA60BM 삽입군에서 술 후 1주, 1달, 2달의 추적관찰 기간 동안 Scheimpflug camera(EAS-1000 Purpose: To report the results of the clinic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Daihan angwa haghoi jabji 2004-12, Vol.45 (12), p.2007-2013
Hauptverfasser: 오세훈, Sae Hoon Oh, 김정권, Jung Kweon Kim, 이도형, Do Hyung Lee
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2013
container_issue 12
container_start_page 2007
container_title Daihan angwa haghoi jabji
container_volume 45
creator 오세훈
Sae Hoon Oh
김정권
Jung Kweon Kim
이도형
Do Hyung Lee
description 목적: 원형전낭절개에 의해 후낭 내에 안전하게 삽입된 single-piece acryl 인공수정체(AcrySof(R), SA60AT, Alcon)의 임상 결과를 three-piece acryl 인공수정체(AcrySof(R), MA60BM, Alcon)와 비교하여 알아보고자 하였다. 대상과 방법: 30안의 SA60AT 삽입군과 30안의 MA60BM 삽입군에서 술 후 1주, 1달, 2달의 추적관찰 기간 동안 Scheimpflug camera(EAS-1000 Purpose: To report the results of the clinical use of single-piece acrylic intraocular lenses (IOLs; AcrySof(R), SA60AT, Alcon) compared with three-piece acrylic IOLs (AcrySof(R), MA60BM, Alcon) after cataract surgery. Methods: We retrospectively analyzed
format Article
fullrecord <record><control><sourceid>kiss_kyobo</sourceid><recordid>TN_cdi_kyobo_bookcenter_4010024330032</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><kiss_id>2389477</kiss_id><sourcerecordid>2389477</sourcerecordid><originalsourceid>FETCH-LOGICAL-k723-84179c54ce2fd046d0fced4b0f2905b86f588649c670faee6f7bb19b8530280d3</originalsourceid><addsrcrecordid>eNotjMtKw0AYRrNQsNQ-gZvZuAz8c0lmsizFGxQU7T5kJjMSEhtJ3GSpdtEXEArS0o379CK48ImS8R202NUH5xy-A6cDlAvXZxwfOb2yTCQAxkyIAHec27au7XRmJyt0l4zvM-3eJFpp1FdFlSE7_2o2nzu_fLPrrZ3PUFuv2petXXygHZ4u0c_7BNnFxL4-o2ZdN5vvY-fQRFmpe_vtOqPzs9Hg0h1eX1wN-kM35YS6gmEeKI8pTUwMzI_BKB0zCYYE4EnhG08InwXK52AirX3DpcSBFB4FIiCmXef0_zatcpmHMs9TpcdPuggZYADCKAWg5K872XdJWYaPRfIQFVVIqAgY5_QXMg1mHw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과</title><source>KoreaMed Open Access</source><creator>오세훈 ; Sae Hoon Oh ; 김정권 ; Jung Kweon Kim ; 이도형 ; Do Hyung Lee</creator><creatorcontrib>오세훈 ; Sae Hoon Oh ; 김정권 ; Jung Kweon Kim ; 이도형 ; Do Hyung Lee</creatorcontrib><description>목적: 원형전낭절개에 의해 후낭 내에 안전하게 삽입된 single-piece acryl 인공수정체(AcrySof(R), SA60AT, Alcon)의 임상 결과를 three-piece acryl 인공수정체(AcrySof(R), MA60BM, Alcon)와 비교하여 알아보고자 하였다. 대상과 방법: 30안의 SA60AT 삽입군과 30안의 MA60BM 삽입군에서 술 후 1주, 1달, 2달의 추적관찰 기간 동안 Scheimpflug camera(EAS-1000 Purpose: To report the results of the clinical use of single-piece acrylic intraocular lenses (IOLs; AcrySof(R), SA60AT, Alcon) compared with three-piece acrylic IOLs (AcrySof(R), MA60BM, Alcon) after cataract surgery. Methods: We retrospectively analyzed</description><identifier>ISSN: 0378-6471</identifier><language>kor</language><publisher>대한안과학회</publisher><subject>Decentration and tilting ; Higher order RMS value ; Predictive refraction and actual refraction ; Single-piece acrylic intraocular lenses</subject><ispartof>Daihan angwa haghoi jabji, 2004-12, Vol.45 (12), p.2007-2013</ispartof><rights>COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>오세훈</creatorcontrib><creatorcontrib>Sae Hoon Oh</creatorcontrib><creatorcontrib>김정권</creatorcontrib><creatorcontrib>Jung Kweon Kim</creatorcontrib><creatorcontrib>이도형</creatorcontrib><creatorcontrib>Do Hyung Lee</creatorcontrib><title>배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과</title><title>Daihan angwa haghoi jabji</title><addtitle>대한안과학회지</addtitle><description>목적: 원형전낭절개에 의해 후낭 내에 안전하게 삽입된 single-piece acryl 인공수정체(AcrySof(R), SA60AT, Alcon)의 임상 결과를 three-piece acryl 인공수정체(AcrySof(R), MA60BM, Alcon)와 비교하여 알아보고자 하였다. 대상과 방법: 30안의 SA60AT 삽입군과 30안의 MA60BM 삽입군에서 술 후 1주, 1달, 2달의 추적관찰 기간 동안 Scheimpflug camera(EAS-1000 Purpose: To report the results of the clinical use of single-piece acrylic intraocular lenses (IOLs; AcrySof(R), SA60AT, Alcon) compared with three-piece acrylic IOLs (AcrySof(R), MA60BM, Alcon) after cataract surgery. Methods: We retrospectively analyzed</description><subject>Decentration and tilting</subject><subject>Higher order RMS value</subject><subject>Predictive refraction and actual refraction</subject><subject>Single-piece acrylic intraocular lenses</subject><issn>0378-6471</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNotjMtKw0AYRrNQsNQ-gZvZuAz8c0lmsizFGxQU7T5kJjMSEhtJ3GSpdtEXEArS0o379CK48ImS8R202NUH5xy-A6cDlAvXZxwfOb2yTCQAxkyIAHec27au7XRmJyt0l4zvM-3eJFpp1FdFlSE7_2o2nzu_fLPrrZ3PUFuv2petXXygHZ4u0c_7BNnFxL4-o2ZdN5vvY-fQRFmpe_vtOqPzs9Hg0h1eX1wN-kM35YS6gmEeKI8pTUwMzI_BKB0zCYYE4EnhG08InwXK52AirX3DpcSBFB4FIiCmXef0_zatcpmHMs9TpcdPuggZYADCKAWg5K872XdJWYaPRfIQFVVIqAgY5_QXMg1mHw</recordid><startdate>20041215</startdate><enddate>20041215</enddate><creator>오세훈</creator><creator>Sae Hoon Oh</creator><creator>김정권</creator><creator>Jung Kweon Kim</creator><creator>이도형</creator><creator>Do Hyung Lee</creator><general>대한안과학회</general><scope>HZB</scope><scope>Q5X</scope><scope>P5Y</scope><scope>SSSTE</scope></search><sort><creationdate>20041215</creationdate><title>배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과</title><author>오세훈 ; Sae Hoon Oh ; 김정권 ; Jung Kweon Kim ; 이도형 ; Do Hyung Lee</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-k723-84179c54ce2fd046d0fced4b0f2905b86f588649c670faee6f7bb19b8530280d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2004</creationdate><topic>Decentration and tilting</topic><topic>Higher order RMS value</topic><topic>Predictive refraction and actual refraction</topic><topic>Single-piece acrylic intraocular lenses</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>오세훈</creatorcontrib><creatorcontrib>Sae Hoon Oh</creatorcontrib><creatorcontrib>김정권</creatorcontrib><creatorcontrib>Jung Kweon Kim</creatorcontrib><creatorcontrib>이도형</creatorcontrib><creatorcontrib>Do Hyung Lee</creatorcontrib><collection>Korean Studies Information Service System (KISS)</collection><collection>Korean Studies Information Service System (KISS) B-Type</collection><collection>Kyobo Scholar (교보스콜라)</collection><collection>Scholar(스콜라)</collection><jtitle>Daihan angwa haghoi jabji</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>오세훈</au><au>Sae Hoon Oh</au><au>김정권</au><au>Jung Kweon Kim</au><au>이도형</au><au>Do Hyung Lee</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과</atitle><jtitle>Daihan angwa haghoi jabji</jtitle><addtitle>대한안과학회지</addtitle><date>2004-12-15</date><risdate>2004</risdate><volume>45</volume><issue>12</issue><spage>2007</spage><epage>2013</epage><pages>2007-2013</pages><issn>0378-6471</issn><abstract>목적: 원형전낭절개에 의해 후낭 내에 안전하게 삽입된 single-piece acryl 인공수정체(AcrySof(R), SA60AT, Alcon)의 임상 결과를 three-piece acryl 인공수정체(AcrySof(R), MA60BM, Alcon)와 비교하여 알아보고자 하였다. 대상과 방법: 30안의 SA60AT 삽입군과 30안의 MA60BM 삽입군에서 술 후 1주, 1달, 2달의 추적관찰 기간 동안 Scheimpflug camera(EAS-1000 Purpose: To report the results of the clinical use of single-piece acrylic intraocular lenses (IOLs; AcrySof(R), SA60AT, Alcon) compared with three-piece acrylic IOLs (AcrySof(R), MA60BM, Alcon) after cataract surgery. Methods: We retrospectively analyzed</abstract><pub>대한안과학회</pub><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-6471
ispartof Daihan angwa haghoi jabji, 2004-12, Vol.45 (12), p.2007-2013
issn 0378-6471
language kor
recordid cdi_kyobo_bookcenter_4010024330032
source KoreaMed Open Access
subjects Decentration and tilting
Higher order RMS value
Predictive refraction and actual refraction
Single-piece acrylic intraocular lenses
title 배수성 Single-Piece Acryl 인공수정체의 백내장 수술 후 임상 결과
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T03%3A57%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kiss_kyobo&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%EB%B0%B0%EC%88%98%EC%84%B1%20Single-Piece%20Acryl%20%EC%9D%B8%EA%B3%B5%EC%88%98%EC%A0%95%EC%B2%B4%EC%9D%98%20%EB%B0%B1%EB%82%B4%EC%9E%A5%20%EC%88%98%EC%88%A0%20%ED%9B%84%20%EC%9E%84%EC%83%81%20%EA%B2%B0%EA%B3%BC&rft.jtitle=Daihan%20angwa%20haghoi%20jabji&rft.au=%EC%98%A4%EC%84%B8%ED%9B%88&rft.date=2004-12-15&rft.volume=45&rft.issue=12&rft.spage=2007&rft.epage=2013&rft.pages=2007-2013&rft.issn=0378-6471&rft_id=info:doi/&rft_dat=%3Ckiss_kyobo%3E2389477%3C/kiss_kyobo%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_kiss_id=2389477&rfr_iscdi=true