Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design

Steady-States Visually Evoked Potentials (SSVEP) refer to the sustained rhythmic activity observed in surface electroencephalography (EEG) in response to the presentation of repetitive visual stimuli (RVS). Due to their robustness and rapid onset, SSVEP have been widely used in Brain Computer Interf...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific Reports 2022-05, Vol.12 (1), p.1-12
Hauptverfasser: Ladouce, Simon, Darmet, Ludovic, Torre-Tresols, Juan Jesus, Velut, Sébastien, Ferraro, Giuseppe, Dehais, Frédéric
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 12
container_issue 1
container_start_page 1
container_title Scientific Reports
container_volume 12
creator Ladouce, Simon
Darmet, Ludovic
Torre-Tresols, Juan Jesus
Velut, Sébastien
Ferraro, Giuseppe
Dehais, Frédéric
description Steady-States Visually Evoked Potentials (SSVEP) refer to the sustained rhythmic activity observed in surface electroencephalography (EEG) in response to the presentation of repetitive visual stimuli (RVS). Due to their robustness and rapid onset, SSVEP have been widely used in Brain Computer Interfaces (BCI). However, typical SSVEP stimuli are straining to the eyes and present risks of triggering epileptic seizures. Reducing visual stimuli contrast or extending their frequency range both appear as relevant solutions to address these issues. It however remains sparsely documented how BCI performance is impacted by these features and to which extent user experience can be improved. We conducted two studies to systematically characterize the effects of frequency and amplitude depth reduction on SSVEP response. The results revealed that although high frequency stimuli improve visual comfort, their classification performance were not competitive enough to design a reliable/responsive BCI. Importantly, we found that the amplitude depth reduction of low frequency RVS is an effective solution to improve user experience while maintaining high classification performance. These findings were further validated by an online T9 SSVEP-BCI in which stimuli with 40% amplitude depth reduction achieved comparable results (>90% accuracy) to full amplitude stimuli while significantly improving user experience.
format Article
fullrecord <record><control><sourceid>kuleuven</sourceid><recordid>TN_cdi_kuleuven_dspace_20_500_12942_737222</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20_500_12942_737222</sourcerecordid><originalsourceid>FETCH-kuleuven_dspace_20_500_12942_7372223</originalsourceid><addsrcrecordid>eNqVTruqAjEUDKKgqP9wasFLPOsitoqinaDYhsWc3Y1mszEPr_69KSxueZ1mBubBdNgA-TyfYobY_aP7bOz9lSfkuJzPlgMm94117UOZCqInB_S05BSZC0FbwvF43hxgtd5DqF0bqxp0-wtFY7UKURJIsqGGwkioVTJLR_eYui_wQTVRqxTwqjIj1isL7Wn84SGbbDen9W56i5rig4yQ3hYXEshFzrmYpXMoFtkCEbMh-_l3WIRnyL5afwMgj1kL</addsrcrecordid><sourcetype>Institutional Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design</title><source>Lirias (KU Leuven Association)</source><source>DOAJ Directory of Open Access Journals</source><source>Springer Nature OA Free Journals</source><source>Nature Free</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Free Full-Text Journals in Chemistry</source><creator>Ladouce, Simon ; Darmet, Ludovic ; Torre-Tresols, Juan Jesus ; Velut, Sébastien ; Ferraro, Giuseppe ; Dehais, Frédéric</creator><creatorcontrib>Ladouce, Simon ; Darmet, Ludovic ; Torre-Tresols, Juan Jesus ; Velut, Sébastien ; Ferraro, Giuseppe ; Dehais, Frédéric</creatorcontrib><description>Steady-States Visually Evoked Potentials (SSVEP) refer to the sustained rhythmic activity observed in surface electroencephalography (EEG) in response to the presentation of repetitive visual stimuli (RVS). Due to their robustness and rapid onset, SSVEP have been widely used in Brain Computer Interfaces (BCI). However, typical SSVEP stimuli are straining to the eyes and present risks of triggering epileptic seizures. Reducing visual stimuli contrast or extending their frequency range both appear as relevant solutions to address these issues. It however remains sparsely documented how BCI performance is impacted by these features and to which extent user experience can be improved. We conducted two studies to systematically characterize the effects of frequency and amplitude depth reduction on SSVEP response. The results revealed that although high frequency stimuli improve visual comfort, their classification performance were not competitive enough to design a reliable/responsive BCI. Importantly, we found that the amplitude depth reduction of low frequency RVS is an effective solution to improve user experience while maintaining high classification performance. These findings were further validated by an online T9 SSVEP-BCI in which stimuli with 40% amplitude depth reduction achieved comparable results (&gt;90% accuracy) to full amplitude stimuli while significantly improving user experience.</description><identifier>ISSN: 2045-2322</identifier><identifier>EISSN: 2045-2322</identifier><language>eng</language><publisher>Nature Portfolio</publisher><ispartof>Scientific Reports, 2022-05, Vol.12 (1), p.1-12</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,315,780,784,27860</link.rule.ids></links><search><creatorcontrib>Ladouce, Simon</creatorcontrib><creatorcontrib>Darmet, Ludovic</creatorcontrib><creatorcontrib>Torre-Tresols, Juan Jesus</creatorcontrib><creatorcontrib>Velut, Sébastien</creatorcontrib><creatorcontrib>Ferraro, Giuseppe</creatorcontrib><creatorcontrib>Dehais, Frédéric</creatorcontrib><title>Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design</title><title>Scientific Reports</title><description>Steady-States Visually Evoked Potentials (SSVEP) refer to the sustained rhythmic activity observed in surface electroencephalography (EEG) in response to the presentation of repetitive visual stimuli (RVS). Due to their robustness and rapid onset, SSVEP have been widely used in Brain Computer Interfaces (BCI). However, typical SSVEP stimuli are straining to the eyes and present risks of triggering epileptic seizures. Reducing visual stimuli contrast or extending their frequency range both appear as relevant solutions to address these issues. It however remains sparsely documented how BCI performance is impacted by these features and to which extent user experience can be improved. We conducted two studies to systematically characterize the effects of frequency and amplitude depth reduction on SSVEP response. The results revealed that although high frequency stimuli improve visual comfort, their classification performance were not competitive enough to design a reliable/responsive BCI. Importantly, we found that the amplitude depth reduction of low frequency RVS is an effective solution to improve user experience while maintaining high classification performance. These findings were further validated by an online T9 SSVEP-BCI in which stimuli with 40% amplitude depth reduction achieved comparable results (&gt;90% accuracy) to full amplitude stimuli while significantly improving user experience.</description><issn>2045-2322</issn><issn>2045-2322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>FZOIL</sourceid><recordid>eNqVTruqAjEUDKKgqP9wasFLPOsitoqinaDYhsWc3Y1mszEPr_69KSxueZ1mBubBdNgA-TyfYobY_aP7bOz9lSfkuJzPlgMm94117UOZCqInB_S05BSZC0FbwvF43hxgtd5DqF0bqxp0-wtFY7UKURJIsqGGwkioVTJLR_eYui_wQTVRqxTwqjIj1isL7Wn84SGbbDen9W56i5rig4yQ3hYXEshFzrmYpXMoFtkCEbMh-_l3WIRnyL5afwMgj1kL</recordid><startdate>20220525</startdate><enddate>20220525</enddate><creator>Ladouce, Simon</creator><creator>Darmet, Ludovic</creator><creator>Torre-Tresols, Juan Jesus</creator><creator>Velut, Sébastien</creator><creator>Ferraro, Giuseppe</creator><creator>Dehais, Frédéric</creator><general>Nature Portfolio</general><scope>FZOIL</scope></search><sort><creationdate>20220525</creationdate><title>Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design</title><author>Ladouce, Simon ; Darmet, Ludovic ; Torre-Tresols, Juan Jesus ; Velut, Sébastien ; Ferraro, Giuseppe ; Dehais, Frédéric</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kuleuven_dspace_20_500_12942_7372223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ladouce, Simon</creatorcontrib><creatorcontrib>Darmet, Ludovic</creatorcontrib><creatorcontrib>Torre-Tresols, Juan Jesus</creatorcontrib><creatorcontrib>Velut, Sébastien</creatorcontrib><creatorcontrib>Ferraro, Giuseppe</creatorcontrib><creatorcontrib>Dehais, Frédéric</creatorcontrib><collection>Lirias (KU Leuven Association)</collection><jtitle>Scientific Reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ladouce, Simon</au><au>Darmet, Ludovic</au><au>Torre-Tresols, Juan Jesus</au><au>Velut, Sébastien</au><au>Ferraro, Giuseppe</au><au>Dehais, Frédéric</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design</atitle><jtitle>Scientific Reports</jtitle><date>2022-05-25</date><risdate>2022</risdate><volume>12</volume><issue>1</issue><spage>1</spage><epage>12</epage><pages>1-12</pages><issn>2045-2322</issn><eissn>2045-2322</eissn><abstract>Steady-States Visually Evoked Potentials (SSVEP) refer to the sustained rhythmic activity observed in surface electroencephalography (EEG) in response to the presentation of repetitive visual stimuli (RVS). Due to their robustness and rapid onset, SSVEP have been widely used in Brain Computer Interfaces (BCI). However, typical SSVEP stimuli are straining to the eyes and present risks of triggering epileptic seizures. Reducing visual stimuli contrast or extending their frequency range both appear as relevant solutions to address these issues. It however remains sparsely documented how BCI performance is impacted by these features and to which extent user experience can be improved. We conducted two studies to systematically characterize the effects of frequency and amplitude depth reduction on SSVEP response. The results revealed that although high frequency stimuli improve visual comfort, their classification performance were not competitive enough to design a reliable/responsive BCI. Importantly, we found that the amplitude depth reduction of low frequency RVS is an effective solution to improve user experience while maintaining high classification performance. These findings were further validated by an online T9 SSVEP-BCI in which stimuli with 40% amplitude depth reduction achieved comparable results (&gt;90% accuracy) to full amplitude stimuli while significantly improving user experience.</abstract><pub>Nature Portfolio</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2045-2322
ispartof Scientific Reports, 2022-05, Vol.12 (1), p.1-12
issn 2045-2322
2045-2322
language eng
recordid cdi_kuleuven_dspace_20_500_12942_737222
source Lirias (KU Leuven Association); DOAJ Directory of Open Access Journals; Springer Nature OA Free Journals; Nature Free; EZB-FREE-00999 freely available EZB journals; PubMed Central; Free Full-Text Journals in Chemistry
title Improving user experience of SSVEP BCI through low amplitude depth and high frequency stimuli design
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T23%3A56%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kuleuven&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Improving%20user%20experience%20of%20SSVEP%20BCI%20through%20low%20amplitude%20depth%20and%20high%20frequency%20stimuli%20design&rft.jtitle=Scientific%20Reports&rft.au=Ladouce,%20Simon&rft.date=2022-05-25&rft.volume=12&rft.issue=1&rft.spage=1&rft.epage=12&rft.pages=1-12&rft.issn=2045-2322&rft.eissn=2045-2322&rft_id=info:doi/&rft_dat=%3Ckuleuven%3E20_500_12942_737222%3C/kuleuven%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true