Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19

PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RADIOLOGY-CARDIOTHORACIC IMAGING 2020-04, Vol.2 (2)
Hauptverfasser: Dangis, Anthony, Gieraerts, Christopher, De Bruecker, Yves, Janssen, Lode, Valgaeren, Hanne, Obbels, Dagmar, Gillis, Marc, Van Ranst, Marc, Frans, Johan, Demeyere, Annick, Symons, Rolf
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title RADIOLOGY-CARDIOTHORACIC IMAGING
container_volume 2
creator Dangis, Anthony
Gieraerts, Christopher
De Bruecker, Yves
Janssen, Lode
Valgaeren, Hanne
Obbels, Dagmar
Gillis, Marc
Van Ranst, Marc
Frans, Johan
Demeyere, Annick
Symons, Rolf
description PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective study. From March 14 to 24, 2020, 192 patients in the emergency department with symptoms suggestive of COVID-19 infection were studied by using low-dose chest CT and real-time reverse transcription polymerase chain reaction (RT-PCR). Image analysis included the likelihood of COVID-19 infection and the semiquantitative extent of lung involvement. CT images were analyzed by two radiologists blinded to the RT-PCR results. Reproducibility was assessed using the McNemar test and intraclass correlation coefficient. Time between CT acquisition and report was measured. RESULTS: When compared with RT-PCR, low-dose submillisievert chest CT demonstrated excellent sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of COVID-19 (86.7%, 93.6%, 91.1%, 90.3%, and 90.2%, respectively), in particular in patients with clinical symptoms for more than 48 hours (95.6%, 93.2%, 91.5%, 96.5%, and 94.4%, respectively). In patients with a positive CT result, the likelihood of disease increased from 43.2% (pretest probability) to 91.1% or 91.4% (posttest probability), while in patients with a negative CT result, the likelihood of disease decreased to 9.6% or 3.7% for all patients or those with clinical symptoms for >48 hours. The prevalence of alternative diagnoses based on chest CT in patients without COVID-19 infection was 17.6%. The mean effective radiation dose was 0.56 mSv ± 0.25 (standard deviation). Median time between CT acquisition and report was 25 minutes (interquartile range: 13-49 minutes). Intra- and interreader reproducibility of CT was excellent (all intraclass correlation coefficients ≥ 0.95) without significant bias in the Bland-Altman analysis. CONCLUSION: Low-dose submillisievert chest CT allows for rapid, accurate, and reproducible assessment of COVID-19 infection in patients in the emergency department, in particular in patients with symptoms lasting longer than 48 hours. Chest CT has the additional advantage of offering alternative diagnoses in a significant subset of patients.© RSNA, 2020.
format Article
fullrecord <record><control><sourceid>kuleuven</sourceid><recordid>TN_cdi_kuleuven_dspace_123456789_674816</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>123456789_674816</sourcerecordid><originalsourceid>FETCH-kuleuven_dspace_123456789_6748163</originalsourceid><addsrcrecordid>eNqVi0FLwzAYhoMoONz-w3fzMApN02btUVrFgTDQsWvI0q8umjWjXzK3fz8HO-yol_d5Ds97w0aZFGUiuShur_yeTYi-0jTNeJ4XvBox9WRMHLQ5gu5beMfd4Nto7No6G47gO3jzP0njCeEjrrfWOUsW9zgEqDdIv7uEzg8QNgiN1Z-9J0vnW71YzZuEV2N212lHOLnwgT2-PC_r1-Q7Oox77FVLO21Q8UzkhZyVlZKzvORS_Kec_q1U4RDECV5aU2s</addsrcrecordid><sourcetype>Institutional Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19</title><source>Lirias (KU Leuven Association)</source><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Dangis, Anthony ; Gieraerts, Christopher ; De Bruecker, Yves ; Janssen, Lode ; Valgaeren, Hanne ; Obbels, Dagmar ; Gillis, Marc ; Van Ranst, Marc ; Frans, Johan ; Demeyere, Annick ; Symons, Rolf</creator><creatorcontrib>Dangis, Anthony ; Gieraerts, Christopher ; De Bruecker, Yves ; Janssen, Lode ; Valgaeren, Hanne ; Obbels, Dagmar ; Gillis, Marc ; Van Ranst, Marc ; Frans, Johan ; Demeyere, Annick ; Symons, Rolf</creatorcontrib><description>PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective study. From March 14 to 24, 2020, 192 patients in the emergency department with symptoms suggestive of COVID-19 infection were studied by using low-dose chest CT and real-time reverse transcription polymerase chain reaction (RT-PCR). Image analysis included the likelihood of COVID-19 infection and the semiquantitative extent of lung involvement. CT images were analyzed by two radiologists blinded to the RT-PCR results. Reproducibility was assessed using the McNemar test and intraclass correlation coefficient. Time between CT acquisition and report was measured. RESULTS: When compared with RT-PCR, low-dose submillisievert chest CT demonstrated excellent sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of COVID-19 (86.7%, 93.6%, 91.1%, 90.3%, and 90.2%, respectively), in particular in patients with clinical symptoms for more than 48 hours (95.6%, 93.2%, 91.5%, 96.5%, and 94.4%, respectively). In patients with a positive CT result, the likelihood of disease increased from 43.2% (pretest probability) to 91.1% or 91.4% (posttest probability), while in patients with a negative CT result, the likelihood of disease decreased to 9.6% or 3.7% for all patients or those with clinical symptoms for &gt;48 hours. The prevalence of alternative diagnoses based on chest CT in patients without COVID-19 infection was 17.6%. The mean effective radiation dose was 0.56 mSv ± 0.25 (standard deviation). Median time between CT acquisition and report was 25 minutes (interquartile range: 13-49 minutes). Intra- and interreader reproducibility of CT was excellent (all intraclass correlation coefficients ≥ 0.95) without significant bias in the Bland-Altman analysis. CONCLUSION: Low-dose submillisievert chest CT allows for rapid, accurate, and reproducible assessment of COVID-19 infection in patients in the emergency department, in particular in patients with symptoms lasting longer than 48 hours. Chest CT has the additional advantage of offering alternative diagnoses in a significant subset of patients.© RSNA, 2020.</description><identifier>ISSN: 2638-6135</identifier><identifier>EISSN: 2638-6135</identifier><language>eng</language><publisher>RADIOLOGICAL SOC NORTH AMERICA (RSNA)</publisher><ispartof>RADIOLOGY-CARDIOTHORACIC IMAGING, 2020-04, Vol.2 (2)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,315,777,781,27841</link.rule.ids></links><search><creatorcontrib>Dangis, Anthony</creatorcontrib><creatorcontrib>Gieraerts, Christopher</creatorcontrib><creatorcontrib>De Bruecker, Yves</creatorcontrib><creatorcontrib>Janssen, Lode</creatorcontrib><creatorcontrib>Valgaeren, Hanne</creatorcontrib><creatorcontrib>Obbels, Dagmar</creatorcontrib><creatorcontrib>Gillis, Marc</creatorcontrib><creatorcontrib>Van Ranst, Marc</creatorcontrib><creatorcontrib>Frans, Johan</creatorcontrib><creatorcontrib>Demeyere, Annick</creatorcontrib><creatorcontrib>Symons, Rolf</creatorcontrib><title>Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19</title><title>RADIOLOGY-CARDIOTHORACIC IMAGING</title><description>PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective study. From March 14 to 24, 2020, 192 patients in the emergency department with symptoms suggestive of COVID-19 infection were studied by using low-dose chest CT and real-time reverse transcription polymerase chain reaction (RT-PCR). Image analysis included the likelihood of COVID-19 infection and the semiquantitative extent of lung involvement. CT images were analyzed by two radiologists blinded to the RT-PCR results. Reproducibility was assessed using the McNemar test and intraclass correlation coefficient. Time between CT acquisition and report was measured. RESULTS: When compared with RT-PCR, low-dose submillisievert chest CT demonstrated excellent sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of COVID-19 (86.7%, 93.6%, 91.1%, 90.3%, and 90.2%, respectively), in particular in patients with clinical symptoms for more than 48 hours (95.6%, 93.2%, 91.5%, 96.5%, and 94.4%, respectively). In patients with a positive CT result, the likelihood of disease increased from 43.2% (pretest probability) to 91.1% or 91.4% (posttest probability), while in patients with a negative CT result, the likelihood of disease decreased to 9.6% or 3.7% for all patients or those with clinical symptoms for &gt;48 hours. The prevalence of alternative diagnoses based on chest CT in patients without COVID-19 infection was 17.6%. The mean effective radiation dose was 0.56 mSv ± 0.25 (standard deviation). Median time between CT acquisition and report was 25 minutes (interquartile range: 13-49 minutes). Intra- and interreader reproducibility of CT was excellent (all intraclass correlation coefficients ≥ 0.95) without significant bias in the Bland-Altman analysis. CONCLUSION: Low-dose submillisievert chest CT allows for rapid, accurate, and reproducible assessment of COVID-19 infection in patients in the emergency department, in particular in patients with symptoms lasting longer than 48 hours. Chest CT has the additional advantage of offering alternative diagnoses in a significant subset of patients.© RSNA, 2020.</description><issn>2638-6135</issn><issn>2638-6135</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>FZOIL</sourceid><recordid>eNqVi0FLwzAYhoMoONz-w3fzMApN02btUVrFgTDQsWvI0q8umjWjXzK3fz8HO-yol_d5Ds97w0aZFGUiuShur_yeTYi-0jTNeJ4XvBox9WRMHLQ5gu5beMfd4Nto7No6G47gO3jzP0njCeEjrrfWOUsW9zgEqDdIv7uEzg8QNgiN1Z-9J0vnW71YzZuEV2N212lHOLnwgT2-PC_r1-Q7Oox77FVLO21Q8UzkhZyVlZKzvORS_Kec_q1U4RDECV5aU2s</recordid><startdate>202004</startdate><enddate>202004</enddate><creator>Dangis, Anthony</creator><creator>Gieraerts, Christopher</creator><creator>De Bruecker, Yves</creator><creator>Janssen, Lode</creator><creator>Valgaeren, Hanne</creator><creator>Obbels, Dagmar</creator><creator>Gillis, Marc</creator><creator>Van Ranst, Marc</creator><creator>Frans, Johan</creator><creator>Demeyere, Annick</creator><creator>Symons, Rolf</creator><general>RADIOLOGICAL SOC NORTH AMERICA (RSNA)</general><scope>FZOIL</scope></search><sort><creationdate>202004</creationdate><title>Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19</title><author>Dangis, Anthony ; Gieraerts, Christopher ; De Bruecker, Yves ; Janssen, Lode ; Valgaeren, Hanne ; Obbels, Dagmar ; Gillis, Marc ; Van Ranst, Marc ; Frans, Johan ; Demeyere, Annick ; Symons, Rolf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kuleuven_dspace_123456789_6748163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dangis, Anthony</creatorcontrib><creatorcontrib>Gieraerts, Christopher</creatorcontrib><creatorcontrib>De Bruecker, Yves</creatorcontrib><creatorcontrib>Janssen, Lode</creatorcontrib><creatorcontrib>Valgaeren, Hanne</creatorcontrib><creatorcontrib>Obbels, Dagmar</creatorcontrib><creatorcontrib>Gillis, Marc</creatorcontrib><creatorcontrib>Van Ranst, Marc</creatorcontrib><creatorcontrib>Frans, Johan</creatorcontrib><creatorcontrib>Demeyere, Annick</creatorcontrib><creatorcontrib>Symons, Rolf</creatorcontrib><collection>Lirias (KU Leuven Association)</collection><jtitle>RADIOLOGY-CARDIOTHORACIC IMAGING</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dangis, Anthony</au><au>Gieraerts, Christopher</au><au>De Bruecker, Yves</au><au>Janssen, Lode</au><au>Valgaeren, Hanne</au><au>Obbels, Dagmar</au><au>Gillis, Marc</au><au>Van Ranst, Marc</au><au>Frans, Johan</au><au>Demeyere, Annick</au><au>Symons, Rolf</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19</atitle><jtitle>RADIOLOGY-CARDIOTHORACIC IMAGING</jtitle><date>2020-04</date><risdate>2020</risdate><volume>2</volume><issue>2</issue><issn>2638-6135</issn><eissn>2638-6135</eissn><abstract>PURPOSE: To demonstrate the accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of coronavirus disease 2019 (COVID-19) infection in patients in the emergency department. MATERIALS AND METHODS: This was a Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective study. From March 14 to 24, 2020, 192 patients in the emergency department with symptoms suggestive of COVID-19 infection were studied by using low-dose chest CT and real-time reverse transcription polymerase chain reaction (RT-PCR). Image analysis included the likelihood of COVID-19 infection and the semiquantitative extent of lung involvement. CT images were analyzed by two radiologists blinded to the RT-PCR results. Reproducibility was assessed using the McNemar test and intraclass correlation coefficient. Time between CT acquisition and report was measured. RESULTS: When compared with RT-PCR, low-dose submillisievert chest CT demonstrated excellent sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for diagnosis of COVID-19 (86.7%, 93.6%, 91.1%, 90.3%, and 90.2%, respectively), in particular in patients with clinical symptoms for more than 48 hours (95.6%, 93.2%, 91.5%, 96.5%, and 94.4%, respectively). In patients with a positive CT result, the likelihood of disease increased from 43.2% (pretest probability) to 91.1% or 91.4% (posttest probability), while in patients with a negative CT result, the likelihood of disease decreased to 9.6% or 3.7% for all patients or those with clinical symptoms for &gt;48 hours. The prevalence of alternative diagnoses based on chest CT in patients without COVID-19 infection was 17.6%. The mean effective radiation dose was 0.56 mSv ± 0.25 (standard deviation). Median time between CT acquisition and report was 25 minutes (interquartile range: 13-49 minutes). Intra- and interreader reproducibility of CT was excellent (all intraclass correlation coefficients ≥ 0.95) without significant bias in the Bland-Altman analysis. CONCLUSION: Low-dose submillisievert chest CT allows for rapid, accurate, and reproducible assessment of COVID-19 infection in patients in the emergency department, in particular in patients with symptoms lasting longer than 48 hours. Chest CT has the additional advantage of offering alternative diagnoses in a significant subset of patients.© RSNA, 2020.</abstract><pub>RADIOLOGICAL SOC NORTH AMERICA (RSNA)</pub></addata></record>
fulltext fulltext
identifier ISSN: 2638-6135
ispartof RADIOLOGY-CARDIOTHORACIC IMAGING, 2020-04, Vol.2 (2)
issn 2638-6135
2638-6135
language eng
recordid cdi_kuleuven_dspace_123456789_674816
source Lirias (KU Leuven Association); PubMed Central; EZB Electronic Journals Library
title Accuracy and Reproducibility of Low-Dose Submillisievert Chest CT for the Diagnosis of COVID-19
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T17%3A43%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kuleuven&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20and%20Reproducibility%20of%20Low-Dose%20Submillisievert%20Chest%20CT%20for%20the%20Diagnosis%20of%20COVID-19&rft.jtitle=RADIOLOGY-CARDIOTHORACIC%20IMAGING&rft.au=Dangis,%20Anthony&rft.date=2020-04&rft.volume=2&rft.issue=2&rft.issn=2638-6135&rft.eissn=2638-6135&rft_id=info:doi/&rft_dat=%3Ckuleuven%3E123456789_674816%3C/kuleuven%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true