Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages
X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative a...
Gespeichert in:
Veröffentlicht in: | Annual Review of Food Science and Technology 2018-03, Vol.9, p.323-343 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 343 |
---|---|
container_issue | |
container_start_page | 323 |
container_title | Annual Review of Food Science and Technology |
container_volume | 9 |
creator | Wang, Zi Herremans, Els Janssen, Siem Cantre, Dennis Verboven, Pieter Nicolai, Bart |
description | X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users. |
format | Article |
fullrecord | <record><control><sourceid>kuleuven</sourceid><recordid>TN_cdi_kuleuven_dspace_123456789_610243</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>123456789_610243</sourcerecordid><originalsourceid>FETCH-kuleuven_dspace_123456789_6102433</originalsourceid><addsrcrecordid>eNqVir0KwjAYADMoWH_eIZuDFJom1tZNrMXFrTq4lNDENlqbki8p4tOLIM46HdzdAHkkYcQnjNARGgNcgyBKYso8dD4pcLxRT9VWmKY401rggyqNBmtcaZ2R-AjvmOu7rgzvalXig7S1FrDGG9Hz1vJKAuatwKkC_jVTNLzwBuTswwmaZ7t8u_dvrpGul20hoOOlLEhI2TJaxUkRkSBklP5zLn47C_uw9AXsolCw</addsrcrecordid><sourcetype>Institutional Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages</title><source>Annual Reviews Complete A-Z List</source><source>Lirias (KU Leuven Association)</source><creator>Wang, Zi ; Herremans, Els ; Janssen, Siem ; Cantre, Dennis ; Verboven, Pieter ; Nicolai, Bart</creator><contributor>Doyle, M.P ; Klaenhammer, T.R</contributor><creatorcontrib>Wang, Zi ; Herremans, Els ; Janssen, Siem ; Cantre, Dennis ; Verboven, Pieter ; Nicolai, Bart ; Doyle, M.P ; Klaenhammer, T.R</creatorcontrib><description>X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users.</description><identifier>ISSN: 1941-1413</identifier><language>eng</language><publisher>Annual Reviews</publisher><ispartof>Annual Review of Food Science and Technology, 2018-03, Vol.9, p.323-343</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,315,776,780,27837</link.rule.ids></links><search><contributor>Doyle, M.P</contributor><contributor>Klaenhammer, T.R</contributor><creatorcontrib>Wang, Zi</creatorcontrib><creatorcontrib>Herremans, Els</creatorcontrib><creatorcontrib>Janssen, Siem</creatorcontrib><creatorcontrib>Cantre, Dennis</creatorcontrib><creatorcontrib>Verboven, Pieter</creatorcontrib><creatorcontrib>Nicolai, Bart</creatorcontrib><title>Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages</title><title>Annual Review of Food Science and Technology</title><description>X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users.</description><issn>1941-1413</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>FZOIL</sourceid><recordid>eNqVir0KwjAYADMoWH_eIZuDFJom1tZNrMXFrTq4lNDENlqbki8p4tOLIM46HdzdAHkkYcQnjNARGgNcgyBKYso8dD4pcLxRT9VWmKY401rggyqNBmtcaZ2R-AjvmOu7rgzvalXig7S1FrDGG9Hz1vJKAuatwKkC_jVTNLzwBuTswwmaZ7t8u_dvrpGul20hoOOlLEhI2TJaxUkRkSBklP5zLn47C_uw9AXsolCw</recordid><startdate>20180325</startdate><enddate>20180325</enddate><creator>Wang, Zi</creator><creator>Herremans, Els</creator><creator>Janssen, Siem</creator><creator>Cantre, Dennis</creator><creator>Verboven, Pieter</creator><creator>Nicolai, Bart</creator><general>Annual Reviews</general><scope>FZOIL</scope></search><sort><creationdate>20180325</creationdate><title>Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages</title><author>Wang, Zi ; Herremans, Els ; Janssen, Siem ; Cantre, Dennis ; Verboven, Pieter ; Nicolai, Bart</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kuleuven_dspace_123456789_6102433</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Zi</creatorcontrib><creatorcontrib>Herremans, Els</creatorcontrib><creatorcontrib>Janssen, Siem</creatorcontrib><creatorcontrib>Cantre, Dennis</creatorcontrib><creatorcontrib>Verboven, Pieter</creatorcontrib><creatorcontrib>Nicolai, Bart</creatorcontrib><collection>Lirias (KU Leuven Association)</collection><jtitle>Annual Review of Food Science and Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Zi</au><au>Herremans, Els</au><au>Janssen, Siem</au><au>Cantre, Dennis</au><au>Verboven, Pieter</au><au>Nicolai, Bart</au><au>Doyle, M.P</au><au>Klaenhammer, T.R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages</atitle><jtitle>Annual Review of Food Science and Technology</jtitle><date>2018-03-25</date><risdate>2018</risdate><volume>9</volume><spage>323</spage><epage>343</epage><pages>323-343</pages><issn>1941-1413</issn><abstract>X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users.</abstract><pub>Annual Reviews</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1941-1413 |
ispartof | Annual Review of Food Science and Technology, 2018-03, Vol.9, p.323-343 |
issn | 1941-1413 |
language | eng |
recordid | cdi_kuleuven_dspace_123456789_610243 |
source | Annual Reviews Complete A-Z List; Lirias (KU Leuven Association) |
title | Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T21%3A06%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kuleuven&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Visualizing%203D%20Food%20Microstructure%20Using%20Tomographic%20Methods:%20Advantages%20and%20Disadvantages&rft.jtitle=Annual%20Review%20of%20Food%20Science%20and%20Technology&rft.au=Wang,%20Zi&rft.date=2018-03-25&rft.volume=9&rft.spage=323&rft.epage=343&rft.pages=323-343&rft.issn=1941-1413&rft_id=info:doi/&rft_dat=%3Ckuleuven%3E123456789_610243%3C/kuleuven%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |