Influence of different boost techniques on radiation dose to the left anterior descending coronary artery
Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on...
Gespeichert in:
Veröffentlicht in: | Radiation oncology journal 2015-09, Vol.33 (3), p.242-249 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | kor |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 249 |
---|---|
container_issue | 3 |
container_start_page | 242 |
container_title | Radiation oncology journal |
container_volume | 33 |
creator | Park, Kawngwoo Lee, Yongha Cha, Jihye You, Sei Hwan Kim, Sunghyun Lee, Jong Young |
description | Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans. |
format | Article |
fullrecord | <record><control><sourceid>kyobo_kisti</sourceid><recordid>TN_cdi_kisti_ndsl_JAKO201532751505714</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4010024720929</sourcerecordid><originalsourceid>FETCH-LOGICAL-k609-3f2ce12bd8c41a29dd7aedd52a3671dd3bd95707e07353c5a44f7851ef6bf0943</originalsourceid><addsrcrecordid>eNpNjz1rwzAYhE1poSHJf9DS0aBPyxpD6EfaQJbsRtb7qhE2EpWUIf--hmbodA_ccdw9NCvOhWwFU93jnZmh9LnZlhJGqoTQXc_4qgmH6OcrRockeQLBe8wYKxlTKpVUdJcYfq5YSIokWwi2hoUgFSQ1kXpBMqOvxMaKOaRMAIvDCCF-E5dyijbfiM2Leds0T97OBbd3XTfnt9fz_qM9nt4P-92xnTpqWuG5Q8ZH6J1klhsAbRFAcSs6zQDECEZpqpFqoYRTVkqve8XQd6OnRop18_JXO4VSwxChzMPn7uvEKVOCa8UUVZr9z93SmIbl77QMX4YOkjJKudScGm7EL5ZQYXc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Influence of different boost techniques on radiation dose to the left anterior descending coronary artery</title><source>KoreaMed Synapse</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>KoreaMed Open Access</source><source>PubMed Central</source><creator>Park, Kawngwoo ; Lee, Yongha ; Cha, Jihye ; You, Sei Hwan ; Kim, Sunghyun ; Lee, Jong Young</creator><creatorcontrib>Park, Kawngwoo ; Lee, Yongha ; Cha, Jihye ; You, Sei Hwan ; Kim, Sunghyun ; Lee, Jong Young</creatorcontrib><description>Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.</description><identifier>ISSN: 2234-1900</identifier><identifier>EISSN: 2234-3156</identifier><language>kor</language><publisher>대한방사선종양학회</publisher><ispartof>Radiation oncology journal, 2015-09, Vol.33 (3), p.242-249</ispartof><rights>COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,315,781,785,886</link.rule.ids></links><search><creatorcontrib>Park, Kawngwoo</creatorcontrib><creatorcontrib>Lee, Yongha</creatorcontrib><creatorcontrib>Cha, Jihye</creatorcontrib><creatorcontrib>You, Sei Hwan</creatorcontrib><creatorcontrib>Kim, Sunghyun</creatorcontrib><creatorcontrib>Lee, Jong Young</creatorcontrib><title>Influence of different boost techniques on radiation dose to the left anterior descending coronary artery</title><title>Radiation oncology journal</title><addtitle>Radiation oncology journal : ROJ</addtitle><description>Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.</description><issn>2234-1900</issn><issn>2234-3156</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>JDI</sourceid><recordid>eNpNjz1rwzAYhE1poSHJf9DS0aBPyxpD6EfaQJbsRtb7qhE2EpWUIf--hmbodA_ccdw9NCvOhWwFU93jnZmh9LnZlhJGqoTQXc_4qgmH6OcrRockeQLBe8wYKxlTKpVUdJcYfq5YSIokWwi2hoUgFSQ1kXpBMqOvxMaKOaRMAIvDCCF-E5dyijbfiM2Leds0T97OBbd3XTfnt9fz_qM9nt4P-92xnTpqWuG5Q8ZH6J1klhsAbRFAcSs6zQDECEZpqpFqoYRTVkqve8XQd6OnRop18_JXO4VSwxChzMPn7uvEKVOCa8UUVZr9z93SmIbl77QMX4YOkjJKudScGm7EL5ZQYXc</recordid><startdate>20150930</startdate><enddate>20150930</enddate><creator>Park, Kawngwoo</creator><creator>Lee, Yongha</creator><creator>Cha, Jihye</creator><creator>You, Sei Hwan</creator><creator>Kim, Sunghyun</creator><creator>Lee, Jong Young</creator><general>대한방사선종양학회</general><general>The Korean Society for Radiation Oncology</general><scope>P5Y</scope><scope>SSSTE</scope><scope>JDI</scope></search><sort><creationdate>20150930</creationdate><title>Influence of different boost techniques on radiation dose to the left anterior descending coronary artery</title><author>Park, Kawngwoo ; Lee, Yongha ; Cha, Jihye ; You, Sei Hwan ; Kim, Sunghyun ; Lee, Jong Young</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-k609-3f2ce12bd8c41a29dd7aedd52a3671dd3bd95707e07353c5a44f7851ef6bf0943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Park, Kawngwoo</creatorcontrib><creatorcontrib>Lee, Yongha</creatorcontrib><creatorcontrib>Cha, Jihye</creatorcontrib><creatorcontrib>You, Sei Hwan</creatorcontrib><creatorcontrib>Kim, Sunghyun</creatorcontrib><creatorcontrib>Lee, Jong Young</creatorcontrib><collection>Kyobo Scholar (교보스콜라)</collection><collection>Scholar(스콜라)</collection><collection>KoreaScience</collection><jtitle>Radiation oncology journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Park, Kawngwoo</au><au>Lee, Yongha</au><au>Cha, Jihye</au><au>You, Sei Hwan</au><au>Kim, Sunghyun</au><au>Lee, Jong Young</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of different boost techniques on radiation dose to the left anterior descending coronary artery</atitle><jtitle>Radiation oncology journal</jtitle><addtitle>Radiation oncology journal : ROJ</addtitle><date>2015-09-30</date><risdate>2015</risdate><volume>33</volume><issue>3</issue><spage>242</spage><epage>249</epage><pages>242-249</pages><issn>2234-1900</issn><eissn>2234-3156</eissn><abstract>Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.</abstract><pub>대한방사선종양학회</pub><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2234-1900 |
ispartof | Radiation oncology journal, 2015-09, Vol.33 (3), p.242-249 |
issn | 2234-1900 2234-3156 |
language | kor |
recordid | cdi_kisti_ndsl_JAKO201532751505714 |
source | KoreaMed Synapse; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; KoreaMed Open Access; PubMed Central |
title | Influence of different boost techniques on radiation dose to the left anterior descending coronary artery |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T06%3A12%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kyobo_kisti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20different%20boost%20techniques%20on%20radiation%20dose%20to%20the%20left%20anterior%20descending%20coronary%20artery&rft.jtitle=Radiation%20oncology%20journal&rft.au=Park,%20Kawngwoo&rft.date=2015-09-30&rft.volume=33&rft.issue=3&rft.spage=242&rft.epage=249&rft.pages=242-249&rft.issn=2234-1900&rft.eissn=2234-3156&rft_id=info:doi/&rft_dat=%3Ckyobo_kisti%3E4010024720929%3C/kyobo_kisti%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |