Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구

Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The object...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Korean Academy of Periodontology 2002, Vol.32 (1), p.199-211
Hauptverfasser: 소성수, 노현수, 김창성, 최성호, 김기덕, 조규성, So, Sung-Soo, Noh, Hyeun-Soo, Kim, Chang-Sung, Choi, Seong-Ho, Kim, Kee-Deog, Cho, Kyoo-Sung
Format: Artikel
Sprache:kor
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 211
container_issue 1
container_start_page 199
container_title Journal of Korean Academy of Periodontology
container_volume 32
creator 소성수
노현수
김창성
최성호
김기덕
조규성
So, Sung-Soo
Noh, Hyeun-Soo
Kim, Chang-Sung
Choi, Seong-Ho
Kim, Kee-Deog
Cho, Kyoo-Sung
description Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both
format Article
fullrecord <record><control><sourceid>kisti</sourceid><recordid>TN_cdi_kisti_ndsl_JAKO200221452721671</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>JAKO200221452721671</sourcerecordid><originalsourceid>FETCH-LOGICAL-k528-91aea736c363531db47510fb36ec82d34b8819ba02cef64aff7e0cae2ad02423</originalsourceid><addsrcrecordid>eNpNjD9Lw0AcQDMoWGq_wy2Ogbvf5ZJ0LLX-LXTQvVySi4QWLV7dWxtB6qBDilVacPAPhQ6F2kHIJ8pdvoOKIk7vLe-tGQUMDJuUMtgwSlJGHqY2OC6zSMEY1lpdLjtCBKjTvpAoH8XqNdbTGOnpu36c5aPJl6VqMUZqMdOXcx0_6ZuJHj7nV5NsmaLt6OTsnKuX9F-gkkS_9fLBNdLjvh70_wI9_d701G2slr38IUHqI85Wd_p-ka3mm8Z6yNtSlH5ZNI52asfVPbPe2N2vVupmi4FrlgkX3KG2T23KKAk8y2EEhx61he9CQC3PdUnZ4xh8EdoWD0NHYJ8L4AEGC2jR2Pq5tiLZjZqngWw3DyqHDcAYgFgMHCC2Q-gnE1uBpw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구</title><source>KoreaMed Open Access</source><creator>소성수 ; 노현수 ; 김창성 ; 최성호 ; 김기덕 ; 조규성 ; So, Sung-Soo ; Noh, Hyeun-Soo ; Kim, Chang-Sung ; Choi, Seong-Ho ; Kim, Kee-Deog ; Cho, Kyoo-Sung</creator><creatorcontrib>소성수 ; 노현수 ; 김창성 ; 최성호 ; 김기덕 ; 조규성 ; So, Sung-Soo ; Noh, Hyeun-Soo ; Kim, Chang-Sung ; Choi, Seong-Ho ; Kim, Kee-Deog ; Cho, Kyoo-Sung</creatorcontrib><description>Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.</description><identifier>ISSN: 0250-3352</identifier><language>kor</language><ispartof>Journal of Korean Academy of Periodontology, 2002, Vol.32 (1), p.199-211</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,4010</link.rule.ids></links><search><creatorcontrib>소성수</creatorcontrib><creatorcontrib>노현수</creatorcontrib><creatorcontrib>김창성</creatorcontrib><creatorcontrib>최성호</creatorcontrib><creatorcontrib>김기덕</creatorcontrib><creatorcontrib>조규성</creatorcontrib><creatorcontrib>So, Sung-Soo</creatorcontrib><creatorcontrib>Noh, Hyeun-Soo</creatorcontrib><creatorcontrib>Kim, Chang-Sung</creatorcontrib><creatorcontrib>Choi, Seong-Ho</creatorcontrib><creatorcontrib>Kim, Kee-Deog</creatorcontrib><creatorcontrib>Cho, Kyoo-Sung</creatorcontrib><title>Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구</title><title>Journal of Korean Academy of Periodontology</title><addtitle>The journal of Korean academy of periodontology</addtitle><description>Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.</description><issn>0250-3352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>JDI</sourceid><recordid>eNpNjD9Lw0AcQDMoWGq_wy2Ogbvf5ZJ0LLX-LXTQvVySi4QWLV7dWxtB6qBDilVacPAPhQ6F2kHIJ8pdvoOKIk7vLe-tGQUMDJuUMtgwSlJGHqY2OC6zSMEY1lpdLjtCBKjTvpAoH8XqNdbTGOnpu36c5aPJl6VqMUZqMdOXcx0_6ZuJHj7nV5NsmaLt6OTsnKuX9F-gkkS_9fLBNdLjvh70_wI9_d701G2slr38IUHqI85Wd_p-ka3mm8Z6yNtSlH5ZNI52asfVPbPe2N2vVupmi4FrlgkX3KG2T23KKAk8y2EEhx61he9CQC3PdUnZ4xh8EdoWD0NHYJ8L4AEGC2jR2Pq5tiLZjZqngWw3DyqHDcAYgFgMHCC2Q-gnE1uBpw</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>소성수</creator><creator>노현수</creator><creator>김창성</creator><creator>최성호</creator><creator>김기덕</creator><creator>조규성</creator><creator>So, Sung-Soo</creator><creator>Noh, Hyeun-Soo</creator><creator>Kim, Chang-Sung</creator><creator>Choi, Seong-Ho</creator><creator>Kim, Kee-Deog</creator><creator>Cho, Kyoo-Sung</creator><scope>JDI</scope></search><sort><creationdate>2002</creationdate><title>Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구</title><author>소성수 ; 노현수 ; 김창성 ; 최성호 ; 김기덕 ; 조규성 ; So, Sung-Soo ; Noh, Hyeun-Soo ; Kim, Chang-Sung ; Choi, Seong-Ho ; Kim, Kee-Deog ; Cho, Kyoo-Sung</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-k528-91aea736c363531db47510fb36ec82d34b8819ba02cef64aff7e0cae2ad02423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2002</creationdate><toplevel>online_resources</toplevel><creatorcontrib>소성수</creatorcontrib><creatorcontrib>노현수</creatorcontrib><creatorcontrib>김창성</creatorcontrib><creatorcontrib>최성호</creatorcontrib><creatorcontrib>김기덕</creatorcontrib><creatorcontrib>조규성</creatorcontrib><creatorcontrib>So, Sung-Soo</creatorcontrib><creatorcontrib>Noh, Hyeun-Soo</creatorcontrib><creatorcontrib>Kim, Chang-Sung</creatorcontrib><creatorcontrib>Choi, Seong-Ho</creatorcontrib><creatorcontrib>Kim, Kee-Deog</creatorcontrib><creatorcontrib>Cho, Kyoo-Sung</creatorcontrib><collection>KoreaScience</collection><jtitle>Journal of Korean Academy of Periodontology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>소성수</au><au>노현수</au><au>김창성</au><au>최성호</au><au>김기덕</au><au>조규성</au><au>So, Sung-Soo</au><au>Noh, Hyeun-Soo</au><au>Kim, Chang-Sung</au><au>Choi, Seong-Ho</au><au>Kim, Kee-Deog</au><au>Cho, Kyoo-Sung</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구</atitle><jtitle>Journal of Korean Academy of Periodontology</jtitle><addtitle>The journal of Korean academy of periodontology</addtitle><date>2002</date><risdate>2002</risdate><volume>32</volume><issue>1</issue><spage>199</spage><epage>211</epage><pages>199-211</pages><issn>0250-3352</issn><abstract>Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.</abstract><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0250-3352
ispartof Journal of Korean Academy of Periodontology, 2002, Vol.32 (1), p.199-211
issn 0250-3352
language kor
recordid cdi_kisti_ndsl_JAKO200221452721671
source KoreaMed Open Access
title Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T04%3A28%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kisti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ektaspeed%20plus%20%ED%95%84%EB%A6%84%EC%9D%84%20%EC%9D%B4%EC%9A%A9%ED%95%9C%20%EC%9D%BC%EB%B0%98%20%EB%B0%A9%EC%82%AC%EC%84%A0%EC%8B%9C%EC%8A%A4%ED%85%9C%EA%B3%BC%20Digora%EB%A5%BC%20%EC%9D%B4%EC%9A%A9%ED%95%9C%20%EB%94%94%EC%A7%80%ED%83%88%20%EC%98%81%EC%83%81%EC%8B%9C%EC%8A%A4%ED%85%9C%EC%9D%98%20%EB%B0%80%EB%8F%84%EB%B3%80%ED%99%94%20%EB%B9%84%EA%B5%90%EC%97%B0%EA%B5%AC&rft.jtitle=Journal%20of%20Korean%20Academy%20of%20Periodontology&rft.au=%EC%86%8C%EC%84%B1%EC%88%98&rft.date=2002&rft.volume=32&rft.issue=1&rft.spage=199&rft.epage=211&rft.pages=199-211&rft.issn=0250-3352&rft_id=info:doi/&rft_dat=%3Ckisti%3EJAKO200221452721671%3C/kisti%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true