[환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출
Solvent extraction of alkali metal and alkaline earth metal cations by mono-crown ether(benzo-15-crown-5) and bis-(crown ether)s(ethylenediamine bis(4'-formyl benzo-15-crown-5)) containing benzo-15-crown-5 moieties were investigated with water-chloroform system at $25^{\circ}C$. The order of th...
Gespeichert in:
Veröffentlicht in: | Punsŏk kwahak 1997, Vol.10 (1), p.60-65 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | kor |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 65 |
---|---|
container_issue | 1 |
container_start_page | 60 |
container_title | Punsŏk kwahak |
container_volume | 10 |
creator | 신영국(Young-Kook Shin) 김해중(Hae-Joong Kim) |
description | Solvent extraction of alkali metal and alkaline earth metal cations by mono-crown ether(benzo-15-crown-5) and bis-(crown ether)s(ethylenediamine bis(4'-formyl benzo-15-crown-5)) containing benzo-15-crown-5 moieties were investigated with water-chloroform system at $25^{\circ}C$. The order of the extraction equilibrium constants($K_e$) and the complexation constants($K_c$) for the alkali metal and alkaline earth metal cations with mono-crown ether and bis-(crown ether)s were Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I) and Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) respectively. These results were explained in terms of the size effect of metal cation and electron density effect. Also, the bis-(crown ether)s was found to extract metal cations more effectively than the corresponding mono-crown ether. mono-crown ether(benzo-15-crown-5)와 benzo-15-crown-5를 포함한 bis-(crown ether)s(ethylenediamine bis(4'-formylbenzo-15-crown-5))에 의한 알칼리금속과 알칼리토금속 양이온들의 용매추출을 $25^{\circ}C$, 물-클로로포름계에서 조사하였다. mono-crown ether와 bis-(crown ether)s를 사용한 경우 알칼리금속과 알칼리토금속 양이온들에 대한 추출평형상수($K_e$)와 착물형성상수($K_c$)의 크기 순위는 각각 Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I)와 Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) 순으로 증가하였다. 이들 크기 순위는 금속 양이온의 크기 및 전자밀도효과로서 설명할 수 있었다. 또한 mono-crown ether에 비해서 bis-(crown ether)s를 사용한 경우 금속양이온들에 대한 추출효율이 좋게 나타남을 알 수 있었다. |
format | Article |
fullrecord | <record><control><sourceid>nurimedia_kisti</sourceid><recordid>TN_cdi_kisti_ndsl_JAKO199719068857271</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><nurid>NODE00642150</nurid><sourcerecordid>NODE00642150</sourcerecordid><originalsourceid>FETCH-LOGICAL-k820-cc31c73b2297c42e46474f19d019f05cb38b65bdf5eac985c320f6d4de1feba03</originalsourceid><addsrcrecordid>eNpNj8tKw0AUhoMoWGrfYTaCLgJzySQzy1rrtdpNdyIhV4ytqWQq4k4QigtdiFZaacFFvYErlaIQX6iZvoORCvVszuHj_w78U0oGY8ZUxhmdVjIIY6pCpJNZJSfEPkyHagbhekY52xl12sO3712wVQ_rQAWFqH4cgmJjz4tk5xQsBSKFC__ookgeYiB7H_LuZdTqAtm6kF9x8vg6_DyXzcvhezxBo-b9mAJ5e_WrtJ-T677stUEqJ099ObiRg-6cMuNbNeHl_nZWqawUK4U1tVReXS_kS2qVYag6DkGOQWyMueFo2NN0zdB8xF2IuA-pYxNm69R2fepZTtrbIRj6uqu5HvI924Ikq8yP31YD0QjM0BU1cyO_WUacG4hDnTFqYANNcuFRFBx4bmCZh-lhRSfmdnm5CKGuYUQh-QGgxIWn</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>[환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>신영국(Young-Kook Shin) ; 김해중(Hae-Joong Kim)</creator><creatorcontrib>신영국(Young-Kook Shin) ; 김해중(Hae-Joong Kim)</creatorcontrib><description>Solvent extraction of alkali metal and alkaline earth metal cations by mono-crown ether(benzo-15-crown-5) and bis-(crown ether)s(ethylenediamine bis(4'-formyl benzo-15-crown-5)) containing benzo-15-crown-5 moieties were investigated with water-chloroform system at $25^{\circ}C$. The order of the extraction equilibrium constants($K_e$) and the complexation constants($K_c$) for the alkali metal and alkaline earth metal cations with mono-crown ether and bis-(crown ether)s were Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I) and Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) respectively. These results were explained in terms of the size effect of metal cation and electron density effect. Also, the bis-(crown ether)s was found to extract metal cations more effectively than the corresponding mono-crown ether. mono-crown ether(benzo-15-crown-5)와 benzo-15-crown-5를 포함한 bis-(crown ether)s(ethylenediamine bis(4'-formylbenzo-15-crown-5))에 의한 알칼리금속과 알칼리토금속 양이온들의 용매추출을 $25^{\circ}C$, 물-클로로포름계에서 조사하였다. mono-crown ether와 bis-(crown ether)s를 사용한 경우 알칼리금속과 알칼리토금속 양이온들에 대한 추출평형상수($K_e$)와 착물형성상수($K_c$)의 크기 순위는 각각 Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I)와 Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) 순으로 증가하였다. 이들 크기 순위는 금속 양이온의 크기 및 전자밀도효과로서 설명할 수 있었다. 또한 mono-crown ether에 비해서 bis-(crown ether)s를 사용한 경우 금속양이온들에 대한 추출효율이 좋게 나타남을 알 수 있었다.</description><identifier>ISSN: 1225-0163</identifier><identifier>EISSN: 2288-8985</identifier><language>kor</language><publisher>한국분석과학회</publisher><ispartof>Punsŏk kwahak, 1997, Vol.10 (1), p.60-65</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,4024</link.rule.ids></links><search><creatorcontrib>신영국(Young-Kook Shin)</creatorcontrib><creatorcontrib>김해중(Hae-Joong Kim)</creatorcontrib><title>[환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출</title><title>Punsŏk kwahak</title><addtitle>Analytical science & technology</addtitle><description>Solvent extraction of alkali metal and alkaline earth metal cations by mono-crown ether(benzo-15-crown-5) and bis-(crown ether)s(ethylenediamine bis(4'-formyl benzo-15-crown-5)) containing benzo-15-crown-5 moieties were investigated with water-chloroform system at $25^{\circ}C$. The order of the extraction equilibrium constants($K_e$) and the complexation constants($K_c$) for the alkali metal and alkaline earth metal cations with mono-crown ether and bis-(crown ether)s were Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I) and Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) respectively. These results were explained in terms of the size effect of metal cation and electron density effect. Also, the bis-(crown ether)s was found to extract metal cations more effectively than the corresponding mono-crown ether. mono-crown ether(benzo-15-crown-5)와 benzo-15-crown-5를 포함한 bis-(crown ether)s(ethylenediamine bis(4'-formylbenzo-15-crown-5))에 의한 알칼리금속과 알칼리토금속 양이온들의 용매추출을 $25^{\circ}C$, 물-클로로포름계에서 조사하였다. mono-crown ether와 bis-(crown ether)s를 사용한 경우 알칼리금속과 알칼리토금속 양이온들에 대한 추출평형상수($K_e$)와 착물형성상수($K_c$)의 크기 순위는 각각 Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I)와 Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) 순으로 증가하였다. 이들 크기 순위는 금속 양이온의 크기 및 전자밀도효과로서 설명할 수 있었다. 또한 mono-crown ether에 비해서 bis-(crown ether)s를 사용한 경우 금속양이온들에 대한 추출효율이 좋게 나타남을 알 수 있었다.</description><issn>1225-0163</issn><issn>2288-8985</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>JDI</sourceid><recordid>eNpNj8tKw0AUhoMoWGrfYTaCLgJzySQzy1rrtdpNdyIhV4ytqWQq4k4QigtdiFZaacFFvYErlaIQX6iZvoORCvVszuHj_w78U0oGY8ZUxhmdVjIIY6pCpJNZJSfEPkyHagbhekY52xl12sO3712wVQ_rQAWFqH4cgmJjz4tk5xQsBSKFC__ookgeYiB7H_LuZdTqAtm6kF9x8vg6_DyXzcvhezxBo-b9mAJ5e_WrtJ-T677stUEqJ099ObiRg-6cMuNbNeHl_nZWqawUK4U1tVReXS_kS2qVYag6DkGOQWyMueFo2NN0zdB8xF2IuA-pYxNm69R2fepZTtrbIRj6uqu5HvI924Ikq8yP31YD0QjM0BU1cyO_WUacG4hDnTFqYANNcuFRFBx4bmCZh-lhRSfmdnm5CKGuYUQh-QGgxIWn</recordid><startdate>1997</startdate><enddate>1997</enddate><creator>신영국(Young-Kook Shin)</creator><creator>김해중(Hae-Joong Kim)</creator><general>한국분석과학회</general><scope>DBRKI</scope><scope>TDB</scope><scope>JDI</scope></search><sort><creationdate>1997</creationdate><title>[환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출</title><author>신영국(Young-Kook Shin) ; 김해중(Hae-Joong Kim)</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-k820-cc31c73b2297c42e46474f19d019f05cb38b65bdf5eac985c320f6d4de1feba03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>1997</creationdate><toplevel>online_resources</toplevel><creatorcontrib>신영국(Young-Kook Shin)</creatorcontrib><creatorcontrib>김해중(Hae-Joong Kim)</creatorcontrib><collection>DBPIA - 디비피아</collection><collection>DBPIA</collection><collection>KoreaScience</collection><jtitle>Punsŏk kwahak</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>신영국(Young-Kook Shin)</au><au>김해중(Hae-Joong Kim)</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>[환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출</atitle><jtitle>Punsŏk kwahak</jtitle><addtitle>Analytical science & technology</addtitle><date>1997</date><risdate>1997</risdate><volume>10</volume><issue>1</issue><spage>60</spage><epage>65</epage><pages>60-65</pages><issn>1225-0163</issn><eissn>2288-8985</eissn><abstract>Solvent extraction of alkali metal and alkaline earth metal cations by mono-crown ether(benzo-15-crown-5) and bis-(crown ether)s(ethylenediamine bis(4'-formyl benzo-15-crown-5)) containing benzo-15-crown-5 moieties were investigated with water-chloroform system at $25^{\circ}C$. The order of the extraction equilibrium constants($K_e$) and the complexation constants($K_c$) for the alkali metal and alkaline earth metal cations with mono-crown ether and bis-(crown ether)s were Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I) and Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) respectively. These results were explained in terms of the size effect of metal cation and electron density effect. Also, the bis-(crown ether)s was found to extract metal cations more effectively than the corresponding mono-crown ether. mono-crown ether(benzo-15-crown-5)와 benzo-15-crown-5를 포함한 bis-(crown ether)s(ethylenediamine bis(4'-formylbenzo-15-crown-5))에 의한 알칼리금속과 알칼리토금속 양이온들의 용매추출을 $25^{\circ}C$, 물-클로로포름계에서 조사하였다. mono-crown ether와 bis-(crown ether)s를 사용한 경우 알칼리금속과 알칼리토금속 양이온들에 대한 추출평형상수($K_e$)와 착물형성상수($K_c$)의 크기 순위는 각각 Ca(II)>Na(I)>Sr(II)>K(I)>Mg(II)>Rb(I)와 Sr(II)>Ca(II)>K(I)>Rb(I)>Mg(II)>Na(I) 순으로 증가하였다. 이들 크기 순위는 금속 양이온의 크기 및 전자밀도효과로서 설명할 수 있었다. 또한 mono-crown ether에 비해서 bis-(crown ether)s를 사용한 경우 금속양이온들에 대한 추출효율이 좋게 나타남을 알 수 있었다.</abstract><pub>한국분석과학회</pub><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1225-0163 |
ispartof | Punsŏk kwahak, 1997, Vol.10 (1), p.60-65 |
issn | 1225-0163 2288-8985 |
language | kor |
recordid | cdi_kisti_ndsl_JAKO199719068857271 |
source | EZB-FREE-00999 freely available EZB journals |
title | [환경] Mono - Crown Ether와 Bis - (Crown Ether)s를 이용한 알칼리금속과 알칼리토금속 양이온들의 용매추출 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T19%3A13%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-nurimedia_kisti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%5B%ED%99%98%EA%B2%BD%5D%20Mono%20-%20Crown%20Ether%EC%99%80%20Bis%20-%20(Crown%20Ether)s%EB%A5%BC%20%EC%9D%B4%EC%9A%A9%ED%95%9C%20%EC%95%8C%EC%B9%BC%EB%A6%AC%EA%B8%88%EC%86%8D%EA%B3%BC%20%EC%95%8C%EC%B9%BC%EB%A6%AC%ED%86%A0%EA%B8%88%EC%86%8D%20%EC%96%91%EC%9D%B4%EC%98%A8%EB%93%A4%EC%9D%98%20%EC%9A%A9%EB%A7%A4%EC%B6%94%EC%B6%9C&rft.jtitle=Puns%C5%8Fk%20kwahak&rft.au=%EC%8B%A0%EC%98%81%EA%B5%AD(Young-Kook%20Shin)&rft.date=1997&rft.volume=10&rft.issue=1&rft.spage=60&rft.epage=65&rft.pages=60-65&rft.issn=1225-0163&rft.eissn=2288-8985&rft_id=info:doi/&rft_dat=%3Cnurimedia_kisti%3ENODE00642150%3C/nurimedia_kisti%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_nurid=NODE00642150&rfr_iscdi=true |