한국 남성 소방공무원의 직무별 심폐능력 및 비만률 비교 분석

Purpose: Firefighting duties range from field roles such as suppression, rescue, and emergency medical services (EMS) to various administrative tasks. Despite these differences, they face uniform fitness standards in Korea. This study seeks to define distinct fitness needs for each duty and provide...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:대한스포츠의학회지 2024-03, Vol.42 (1), p.23
Hauptverfasser: 김지빈, Ji-been Kim, 제민건, Min-geon Je, 김채빈, Chae-been Kim, 박정준, Jung-jun Park, 강현주, Hyun-joo Kang, 송욱, Wook Song, 이충근, Chung-gun Lee, 안연순, Yeon-soon Ahn, 이한준, Han-joon Lee, 서동일, Dong-il Seo
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: Firefighting duties range from field roles such as suppression, rescue, and emergency medical services (EMS) to various administrative tasks. Despite these differences, they face uniform fitness standards in Korea. This study seeks to define distinct fitness needs for each duty and provide data for customized standards. Methods: One hundred seventy-six Korean male firefighters participated, categorized into suppression (n=76), rescue (n=22), administrative (n=27), and EMS (n=51) roles. All underwent maximal oxygen consumption (VO 2 max) tests for aerobic capacity, with body composition measured using bioelectrical impedance and height recorded with a stadiometer. Results: The VO 2 max (mL/kg/min) among Korean male firefighters varied across different job duties: suppression (39.96±5.84), rescue (44.84±4.85), administration (40.27±7.01), and EMS (40.51±6.75). Rescue had the highest VO 2 max, which was significantly higher (p=0.013). The body mass index (BMI, kg/m 2 ) values were as follows: suppression (25.07±2.55), rescue (24.95±1.71), EMS (24.33±3.21), and administration (25.10±2.48). There was no statistically significant difference in BMI values (p=0.464). Conclusion: This study evaluated the VO 2 max and BMI of South Korean male firefighters according to their job duties. It found that 54.5% did not meet the recommended VO 2 max standard of 42 mL/kg/min for their activities, and 77.5% had a BMI indicating overweight or higher. However, it is important to note that not every firefighting duty requires high fitness levels. The key is ensuring firefighters possess the fitness necessary for their specific roles to maintain safety and efficiency. The study aims to provide data for creating fitness management guidelines tailored to the diverse duties of firefighters.
ISSN:1226-3729