Endotracheal intubation using i-gel® and lightwand in a patient with difficult airway -a case report
This case report involves tracheal intubation using i-gel® in combination with a lightwand in a patient with a difficult airway, classified as Cormack-Lehane grade 3. I-gel® was used during anesthesia induction to properly maintain ventilation. The authors have previously reported successful trachea...
Gespeichert in:
Veröffentlicht in: | Korean journal of anesthesiology 2015-10, Vol.68 (5), p.501 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This case report involves tracheal intubation using i-gel® in combination with a lightwand in a patient with a difficult airway, classified as Cormack-Lehane grade 3. I-gel® was used during anesthesia induction to properly maintain ventilation. The authors have previously reported successful tracheal intubation on a patient with a difficult airway through the use of i-gel® and a fiberoptic bronchoscope. However, if the use of a fiberoptic bronchoscope is not immediately available in a patient with a difficult airway, tracheal intubation may be performed by using i-gel® and a lightwand in a patient with difficult airway, allowing the safe induction of anesthesia. |
---|---|
ISSN: | 2005-6419 |