The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP
Background/Aims: Brush cytology during ERCP can provide a pathologic diagnosis in malignant biliary obstruction. K-ras and p53 mutations are commonly found in biliary and pancreatic cancers. We evaluated the diagnostic yield of brush cytology and the changes obtained by adding p53 and K-ras staining...
Gespeichert in:
Veröffentlicht in: | Gut and liver 2010-06, Vol.4 (2), p.219 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 2 |
container_start_page | 219 |
container_title | Gut and liver |
container_volume | 4 |
creator | Young Sup Kim Ho Gak Kim Ji Min Han Change Jae Hur Byeong Suk Kim Jin Tae Jung Joong Goo Kwon Eun Young Kim Chang Ho Cho Yoon Kyung Sohn |
description | Background/Aims: Brush cytology during ERCP can provide a pathologic diagnosis in malignant biliary obstruction. K-ras and p53 mutations are commonly found in biliary and pancreatic cancers. We evaluated the diagnostic yield of brush cytology and the changes obtained by adding p53 and K-ras staining. Methods: One hundred and forty patients with biliary obstruction who underwent ERCP with brush cytology during a 7-year period were included. The sensitivity and specificity of brush cytology only and with the addition of p53 and K-ras staining were obtained. Results: Malignant biliary obstruction was confirmed in 119 patients. The sensitivity and specificity of brush cytology were 78.2% and 90.5%, respectively. The sensitivity of cytology was 77.3% at the ampulla-distal common bile duct (CBD), 92.6% at the mid common hepatic duct (CHD), and 94.7% at the proximal CBD-CHD (p<0.05); these values did not differ with the degree or the length of the obstruction. In the 97 patients who received additional p53 and K-ras staining, the sensitivity of cytology plus p53 was 88.2%, cytology plus K-ras was 84.0%, and cytology plus p53 and K-ras was 88.2%. The sensitivity of cytology plus p53 was higher than that of brush cytology only (95% confidence interval: 83.69-92.78 vs 72.65-83.65) but not that of cytology plus K-ras. Conclusions: Brush cytology for malignant biliary obstruction has a high diagnostic accuracy. Adding p53 staining can further improve the diagnostic yield, whereas K-ras staining does not. (Gut Liver 2010;4:219-225) |
format | Article |
fullrecord | <record><control><sourceid>kiss</sourceid><recordid>TN_cdi_kiss_primary_3034939</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><kiss_id>3034939</kiss_id><sourcerecordid>3034939</sourcerecordid><originalsourceid>FETCH-kiss_primary_30349393</originalsourceid><addsrcrecordid>eNp9zE1uwjAQBWAvWgkonIDNXCBSiPnLlhTUClVUhT0aTH6mdcbI4yxyiN65RmLd1Vu8974nNZzlq2WSZWs9UCOR7zRdzrLVYqh-T00JR6qZKjLIpgRXwW2hAfkK-8SjwHvbduxMH5xpyjauLBwDEhPXQAwhAq-ENTshub8_0EYPOcCGLKHv4XCR4DsTyDFcetj4ThooImhd3cO183dq-1V8jtVzhVbKySNf1HS3PRVvyQ-JnG-e2siddarnuc71_-0fFEROMw</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>KoreaMed Open Access</source><source>PubMed Central</source><creator>Young Sup Kim ; Ho Gak Kim ; Ji Min Han ; Change Jae Hur ; Byeong Suk Kim ; Jin Tae Jung ; Joong Goo Kwon ; Eun Young Kim ; Chang Ho Cho ; Yoon Kyung Sohn</creator><creatorcontrib>Young Sup Kim ; Ho Gak Kim ; Ji Min Han ; Change Jae Hur ; Byeong Suk Kim ; Jin Tae Jung ; Joong Goo Kwon ; Eun Young Kim ; Chang Ho Cho ; Yoon Kyung Sohn</creatorcontrib><description>Background/Aims: Brush cytology during ERCP can provide a pathologic diagnosis in malignant biliary obstruction. K-ras and p53 mutations are commonly found in biliary and pancreatic cancers. We evaluated the diagnostic yield of brush cytology and the changes obtained by adding p53 and K-ras staining. Methods: One hundred and forty patients with biliary obstruction who underwent ERCP with brush cytology during a 7-year period were included. The sensitivity and specificity of brush cytology only and with the addition of p53 and K-ras staining were obtained. Results: Malignant biliary obstruction was confirmed in 119 patients. The sensitivity and specificity of brush cytology were 78.2% and 90.5%, respectively. The sensitivity of cytology was 77.3% at the ampulla-distal common bile duct (CBD), 92.6% at the mid common hepatic duct (CHD), and 94.7% at the proximal CBD-CHD (p<0.05); these values did not differ with the degree or the length of the obstruction. In the 97 patients who received additional p53 and K-ras staining, the sensitivity of cytology plus p53 was 88.2%, cytology plus K-ras was 84.0%, and cytology plus p53 and K-ras was 88.2%. The sensitivity of cytology plus p53 was higher than that of brush cytology only (95% confidence interval: 83.69-92.78 vs 72.65-83.65) but not that of cytology plus K-ras. Conclusions: Brush cytology for malignant biliary obstruction has a high diagnostic accuracy. Adding p53 staining can further improve the diagnostic yield, whereas K-ras staining does not. (Gut Liver 2010;4:219-225)</description><identifier>ISSN: 1976-2283</identifier><language>kor</language><publisher>대한소화기학회</publisher><subject>Brush cytology ; ERCP ; Immunocytochemical stain ; Malignant biliary obstruction</subject><ispartof>Gut and liver, 2010-06, Vol.4 (2), p.219</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Young Sup Kim</creatorcontrib><creatorcontrib>Ho Gak Kim</creatorcontrib><creatorcontrib>Ji Min Han</creatorcontrib><creatorcontrib>Change Jae Hur</creatorcontrib><creatorcontrib>Byeong Suk Kim</creatorcontrib><creatorcontrib>Jin Tae Jung</creatorcontrib><creatorcontrib>Joong Goo Kwon</creatorcontrib><creatorcontrib>Eun Young Kim</creatorcontrib><creatorcontrib>Chang Ho Cho</creatorcontrib><creatorcontrib>Yoon Kyung Sohn</creatorcontrib><title>The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP</title><title>Gut and liver</title><addtitle>Gut and Liver</addtitle><description>Background/Aims: Brush cytology during ERCP can provide a pathologic diagnosis in malignant biliary obstruction. K-ras and p53 mutations are commonly found in biliary and pancreatic cancers. We evaluated the diagnostic yield of brush cytology and the changes obtained by adding p53 and K-ras staining. Methods: One hundred and forty patients with biliary obstruction who underwent ERCP with brush cytology during a 7-year period were included. The sensitivity and specificity of brush cytology only and with the addition of p53 and K-ras staining were obtained. Results: Malignant biliary obstruction was confirmed in 119 patients. The sensitivity and specificity of brush cytology were 78.2% and 90.5%, respectively. The sensitivity of cytology was 77.3% at the ampulla-distal common bile duct (CBD), 92.6% at the mid common hepatic duct (CHD), and 94.7% at the proximal CBD-CHD (p<0.05); these values did not differ with the degree or the length of the obstruction. In the 97 patients who received additional p53 and K-ras staining, the sensitivity of cytology plus p53 was 88.2%, cytology plus K-ras was 84.0%, and cytology plus p53 and K-ras was 88.2%. The sensitivity of cytology plus p53 was higher than that of brush cytology only (95% confidence interval: 83.69-92.78 vs 72.65-83.65) but not that of cytology plus K-ras. Conclusions: Brush cytology for malignant biliary obstruction has a high diagnostic accuracy. Adding p53 staining can further improve the diagnostic yield, whereas K-ras staining does not. (Gut Liver 2010;4:219-225)</description><subject>Brush cytology</subject><subject>ERCP</subject><subject>Immunocytochemical stain</subject><subject>Malignant biliary obstruction</subject><issn>1976-2283</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9zE1uwjAQBWAvWgkonIDNXCBSiPnLlhTUClVUhT0aTH6mdcbI4yxyiN65RmLd1Vu8974nNZzlq2WSZWs9UCOR7zRdzrLVYqh-T00JR6qZKjLIpgRXwW2hAfkK-8SjwHvbduxMH5xpyjauLBwDEhPXQAwhAq-ENTshub8_0EYPOcCGLKHv4XCR4DsTyDFcetj4ThooImhd3cO183dq-1V8jtVzhVbKySNf1HS3PRVvyQ-JnG-e2siddarnuc71_-0fFEROMw</recordid><startdate>20100630</startdate><enddate>20100630</enddate><creator>Young Sup Kim</creator><creator>Ho Gak Kim</creator><creator>Ji Min Han</creator><creator>Change Jae Hur</creator><creator>Byeong Suk Kim</creator><creator>Jin Tae Jung</creator><creator>Joong Goo Kwon</creator><creator>Eun Young Kim</creator><creator>Chang Ho Cho</creator><creator>Yoon Kyung Sohn</creator><general>대한소화기학회</general><scope>HZB</scope><scope>Q5X</scope></search><sort><creationdate>20100630</creationdate><title>The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP</title><author>Young Sup Kim ; Ho Gak Kim ; Ji Min Han ; Change Jae Hur ; Byeong Suk Kim ; Jin Tae Jung ; Joong Goo Kwon ; Eun Young Kim ; Chang Ho Cho ; Yoon Kyung Sohn</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kiss_primary_30349393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2010</creationdate><topic>Brush cytology</topic><topic>ERCP</topic><topic>Immunocytochemical stain</topic><topic>Malignant biliary obstruction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Young Sup Kim</creatorcontrib><creatorcontrib>Ho Gak Kim</creatorcontrib><creatorcontrib>Ji Min Han</creatorcontrib><creatorcontrib>Change Jae Hur</creatorcontrib><creatorcontrib>Byeong Suk Kim</creatorcontrib><creatorcontrib>Jin Tae Jung</creatorcontrib><creatorcontrib>Joong Goo Kwon</creatorcontrib><creatorcontrib>Eun Young Kim</creatorcontrib><creatorcontrib>Chang Ho Cho</creatorcontrib><creatorcontrib>Yoon Kyung Sohn</creatorcontrib><collection>Korean Studies Information Service System (KISS)</collection><collection>Korean Studies Information Service System (KISS) B-Type</collection><jtitle>Gut and liver</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Young Sup Kim</au><au>Ho Gak Kim</au><au>Ji Min Han</au><au>Change Jae Hur</au><au>Byeong Suk Kim</au><au>Jin Tae Jung</au><au>Joong Goo Kwon</au><au>Eun Young Kim</au><au>Chang Ho Cho</au><au>Yoon Kyung Sohn</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP</atitle><jtitle>Gut and liver</jtitle><addtitle>Gut and Liver</addtitle><date>2010-06-30</date><risdate>2010</risdate><volume>4</volume><issue>2</issue><spage>219</spage><pages>219-</pages><issn>1976-2283</issn><abstract>Background/Aims: Brush cytology during ERCP can provide a pathologic diagnosis in malignant biliary obstruction. K-ras and p53 mutations are commonly found in biliary and pancreatic cancers. We evaluated the diagnostic yield of brush cytology and the changes obtained by adding p53 and K-ras staining. Methods: One hundred and forty patients with biliary obstruction who underwent ERCP with brush cytology during a 7-year period were included. The sensitivity and specificity of brush cytology only and with the addition of p53 and K-ras staining were obtained. Results: Malignant biliary obstruction was confirmed in 119 patients. The sensitivity and specificity of brush cytology were 78.2% and 90.5%, respectively. The sensitivity of cytology was 77.3% at the ampulla-distal common bile duct (CBD), 92.6% at the mid common hepatic duct (CHD), and 94.7% at the proximal CBD-CHD (p<0.05); these values did not differ with the degree or the length of the obstruction. In the 97 patients who received additional p53 and K-ras staining, the sensitivity of cytology plus p53 was 88.2%, cytology plus K-ras was 84.0%, and cytology plus p53 and K-ras was 88.2%. The sensitivity of cytology plus p53 was higher than that of brush cytology only (95% confidence interval: 83.69-92.78 vs 72.65-83.65) but not that of cytology plus K-ras. Conclusions: Brush cytology for malignant biliary obstruction has a high diagnostic accuracy. Adding p53 staining can further improve the diagnostic yield, whereas K-ras staining does not. (Gut Liver 2010;4:219-225)</abstract><pub>대한소화기학회</pub><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1976-2283 |
ispartof | Gut and liver, 2010-06, Vol.4 (2), p.219 |
issn | 1976-2283 |
language | kor |
recordid | cdi_kiss_primary_3034939 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; KoreaMed Open Access; PubMed Central |
subjects | Brush cytology ERCP Immunocytochemical stain Malignant biliary obstruction |
title | The Significance of p53 and K-ras Immunocytochemical Staining in the Diagnosis of Malignant Biliary Obstruction by Brush Cytology during ERCP |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T06%3A42%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kiss&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Significance%20of%20p53%20and%20K-ras%20Immunocytochemical%20Staining%20in%20the%20Diagnosis%20of%20Malignant%20Biliary%20Obstruction%20by%20Brush%20Cytology%20during%20ERCP&rft.jtitle=Gut%20and%20liver&rft.au=Young%20Sup%20Kim&rft.date=2010-06-30&rft.volume=4&rft.issue=2&rft.spage=219&rft.pages=219-&rft.issn=1976-2283&rft_id=info:doi/&rft_dat=%3Ckiss%3E3034939%3C/kiss%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_kiss_id=3034939&rfr_iscdi=true |