간세포암종 진단에 있어서 자동화 분석기로 측정한 AFP - L3 와 PIVKA - 2 의 임상적 유용성

Background / Aims : Prothrombin induced by Vitamin K Antagonist-Ⅱ(PIVKA-Ⅱ)and alpha-fetoprotein(AFP)subtype reacting with Lens Culinaris Agglutinin(AFP-L3)are known as specific tumor markers for HCC. Recently a more sensitive ELA method for PIVKA-Ⅱand an automatic analyzer with Liquid Phase Binding...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical and molecular hepatology 2001-12, Vol.7 (4), p.467
Hauptverfasser: 이현웅, Hyun Woong Lee, 전재윤, Chae Yoon Chon, 이관식, Kwan Sik Lee, 박영수, Young Soo Park, 정재연, Jae Yeon Cheong, 송건훈, Kun Hoon Song, 문영명, Young Myoung Moon, 백용한, Yong Han Paik, 김철, Cheol Kim, 한광엽, Kwang Hyub Han, 박정엽, Jeong Youp Park, 전태주, Tae Joo Jeon, 한재용, Jae Yong Han, 이경률
Format: Artikel
Sprache:kor
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background / Aims : Prothrombin induced by Vitamin K Antagonist-Ⅱ(PIVKA-Ⅱ)and alpha-fetoprotein(AFP)subtype reacting with Lens Culinaris Agglutinin(AFP-L3)are known as specific tumor markers for HCC. Recently a more sensitive ELA method for PIVKA-Ⅱand an automatic analyzer with Liquid Phase Binding Assay method(LBA method)for AFP-L3 have been developed. The aim of this study was to evaluate the feasibility of PIVKA-Ⅱ and AFP-L3 measured by newly developed methods as complementary tumor markers to AFP in the diagnosis of HCC. Methods : The serum concentration of AFP, PIVKA-Ⅱ, and a fraction of AFP-L3 were determined from 188 patients with HCC and 118 patients with various liver diseases including tumors of the liver. AFP was measured by EIA, PIVKA-Ⅱ by sensitive EIA, and AFP-L3 by the LBA method with LiBASys Auto-analyzer. The cutoff values for AFP, PIVKA-Ⅱ, AND AFP-L3 WERE 400ng/mL, 40 Mau/mL, AND 15%, respectively. Results : The sensitivity and specificity of serum PIVKA-Ⅱwere 69.2% and 76.5%, respectively. Sixty-two(51.2%) of 121 patients with HCC, in which AFP was less than 400ng/mL were PIVKA-Ⅱ positive. The specificity and specificity of serum AFP-L3 were 48.8% and 90.8%, respectively. When AFP-L3 was used in combination with PIVKA-Ⅱ,31(46.3%) of the 67 patients with small less than 3cm HCC were positive for at least one of these markers. Conclusion : PIVKA-Ⅱ measures by sensitive EIA may be useful for the diagnosis of HCC with low AFP level. AFP-L3 and PIVKA-Ⅱ may improve the detection rate of small HCCs less than 3cm.
ISSN:2287-2728