Dialysis, Ultrafiltration, and Blood Pressure

The effect of ultrafiltration on blood pressure was compared in six patients with problems of overhydration during single-pass dialysis, ultrafiltration only (the fluid bypassing the dialyser) and recirculation dialysis (using the RP 6 dialyser and the 75 l Rodial system). Adequate ultrafiltration d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Blood purification 2006-02, Vol.24 (2), p.222-229
Hauptverfasser: Bergström, J., Asaba, H., Fürst, P., Oulès, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 229
container_issue 2
container_start_page 222
container_title Blood purification
container_volume 24
creator Bergström, J.
Asaba, H.
Fürst, P.
Oulès, R.
description The effect of ultrafiltration on blood pressure was compared in six patients with problems of overhydration during single-pass dialysis, ultrafiltration only (the fluid bypassing the dialyser) and recirculation dialysis (using the RP 6 dialyser and the 75 l Rodial system). Adequate ultrafiltration during single-pass dialysis was hampered by symptomatic hypotension. However, during recirculation dialysis as well as during ultrafiltration without dialysis much more rapid ultrafiltration was tolerated without a fall in blood pressure. A considerable fall in plasma osmolality occurred with single-pass dialysis, whereas only a small decrease occurred with recirculation dialysis and no change with ultrafiltration only. We conclude that a rapid fall in plasma osmolality interferes with blood pressure regulation and that ultrafiltration is far better tolerated provided that osmotic shifts are avoided or minimised.
doi_str_mv 10.1159/000091016
format Article
fullrecord <record><control><sourceid>karger_cross</sourceid><recordid>TN_cdi_karger_primary_91016</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>91016</sourcerecordid><originalsourceid>FETCH-LOGICAL-c284t-c5c154d4b8e6ce43bb34163cb217b00d408e6875ff9ebb1f0cb68c09589456e03</originalsourceid><addsrcrecordid>eNo9jz1PwzAYhC0EoqEwMLNkRarhfeOP2COUT6kSDHSObMdGhtAgOwz9900V1Bvuhnt00hFyiXCDKPQtjNIIKI9IgbxCqmsmjkkBlWBUgFQzcpbzFwByKfQpmaHklVK1Lgh9iKbb5pgX5bobkglx70PsN4vSbNryvuv7tnxPPue_5M_JSTBd9hf_OSfrp8eP5QtdvT2_Lu9W1FWKD9QJh4K33CovnefMWsZRMmcrrC1Ay2EsVC1C0N5aDOCsVA60UJoL6YHNyfW061Kfc_Kh-U3xx6Rtg9DsLzeHyyN7NbHfJn36dCCndgf15k5e</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Dialysis, Ultrafiltration, and Blood Pressure</title><source>Karger Journals</source><creator>Bergström, J. ; Asaba, H. ; Fürst, P. ; Oulès, R.</creator><creatorcontrib>Bergström, J. ; Asaba, H. ; Fürst, P. ; Oulès, R.</creatorcontrib><description>The effect of ultrafiltration on blood pressure was compared in six patients with problems of overhydration during single-pass dialysis, ultrafiltration only (the fluid bypassing the dialyser) and recirculation dialysis (using the RP 6 dialyser and the 75 l Rodial system). Adequate ultrafiltration during single-pass dialysis was hampered by symptomatic hypotension. However, during recirculation dialysis as well as during ultrafiltration without dialysis much more rapid ultrafiltration was tolerated without a fall in blood pressure. A considerable fall in plasma osmolality occurred with single-pass dialysis, whereas only a small decrease occurred with recirculation dialysis and no change with ultrafiltration only. We conclude that a rapid fall in plasma osmolality interferes with blood pressure regulation and that ultrafiltration is far better tolerated provided that osmotic shifts are avoided or minimised.</description><identifier>ISSN: 0253-5068</identifier><identifier>EISSN: 1421-9735</identifier><identifier>DOI: 10.1159/000091016</identifier><identifier>PMID: 16428879</identifier><language>eng</language><publisher>Basel, Switzerland</publisher><subject>Historical Perspectives</subject><ispartof>Blood purification, 2006-02, Vol.24 (2), p.222-229</ispartof><rights>2006 S. Karger AG, Basel</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c284t-c5c154d4b8e6ce43bb34163cb217b00d408e6875ff9ebb1f0cb68c09589456e03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,2423,27901,27902</link.rule.ids></links><search><creatorcontrib>Bergström, J.</creatorcontrib><creatorcontrib>Asaba, H.</creatorcontrib><creatorcontrib>Fürst, P.</creatorcontrib><creatorcontrib>Oulès, R.</creatorcontrib><title>Dialysis, Ultrafiltration, and Blood Pressure</title><title>Blood purification</title><addtitle>Blood Purif</addtitle><description>The effect of ultrafiltration on blood pressure was compared in six patients with problems of overhydration during single-pass dialysis, ultrafiltration only (the fluid bypassing the dialyser) and recirculation dialysis (using the RP 6 dialyser and the 75 l Rodial system). Adequate ultrafiltration during single-pass dialysis was hampered by symptomatic hypotension. However, during recirculation dialysis as well as during ultrafiltration without dialysis much more rapid ultrafiltration was tolerated without a fall in blood pressure. A considerable fall in plasma osmolality occurred with single-pass dialysis, whereas only a small decrease occurred with recirculation dialysis and no change with ultrafiltration only. We conclude that a rapid fall in plasma osmolality interferes with blood pressure regulation and that ultrafiltration is far better tolerated provided that osmotic shifts are avoided or minimised.</description><subject>Historical Perspectives</subject><issn>0253-5068</issn><issn>1421-9735</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNo9jz1PwzAYhC0EoqEwMLNkRarhfeOP2COUT6kSDHSObMdGhtAgOwz9900V1Bvuhnt00hFyiXCDKPQtjNIIKI9IgbxCqmsmjkkBlWBUgFQzcpbzFwByKfQpmaHklVK1Lgh9iKbb5pgX5bobkglx70PsN4vSbNryvuv7tnxPPue_5M_JSTBd9hf_OSfrp8eP5QtdvT2_Lu9W1FWKD9QJh4K33CovnefMWsZRMmcrrC1Ay2EsVC1C0N5aDOCsVA60UJoL6YHNyfW061Kfc_Kh-U3xx6Rtg9DsLzeHyyN7NbHfJn36dCCndgf15k5e</recordid><startdate>200602</startdate><enddate>200602</enddate><creator>Bergström, J.</creator><creator>Asaba, H.</creator><creator>Fürst, P.</creator><creator>Oulès, R.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200602</creationdate><title>Dialysis, Ultrafiltration, and Blood Pressure</title><author>Bergström, J. ; Asaba, H. ; Fürst, P. ; Oulès, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c284t-c5c154d4b8e6ce43bb34163cb217b00d408e6875ff9ebb1f0cb68c09589456e03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Historical Perspectives</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bergström, J.</creatorcontrib><creatorcontrib>Asaba, H.</creatorcontrib><creatorcontrib>Fürst, P.</creatorcontrib><creatorcontrib>Oulès, R.</creatorcontrib><collection>CrossRef</collection><jtitle>Blood purification</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bergström, J.</au><au>Asaba, H.</au><au>Fürst, P.</au><au>Oulès, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dialysis, Ultrafiltration, and Blood Pressure</atitle><jtitle>Blood purification</jtitle><addtitle>Blood Purif</addtitle><date>2006-02</date><risdate>2006</risdate><volume>24</volume><issue>2</issue><spage>222</spage><epage>229</epage><pages>222-229</pages><issn>0253-5068</issn><eissn>1421-9735</eissn><abstract>The effect of ultrafiltration on blood pressure was compared in six patients with problems of overhydration during single-pass dialysis, ultrafiltration only (the fluid bypassing the dialyser) and recirculation dialysis (using the RP 6 dialyser and the 75 l Rodial system). Adequate ultrafiltration during single-pass dialysis was hampered by symptomatic hypotension. However, during recirculation dialysis as well as during ultrafiltration without dialysis much more rapid ultrafiltration was tolerated without a fall in blood pressure. A considerable fall in plasma osmolality occurred with single-pass dialysis, whereas only a small decrease occurred with recirculation dialysis and no change with ultrafiltration only. We conclude that a rapid fall in plasma osmolality interferes with blood pressure regulation and that ultrafiltration is far better tolerated provided that osmotic shifts are avoided or minimised.</abstract><cop>Basel, Switzerland</cop><pmid>16428879</pmid><doi>10.1159/000091016</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0253-5068
ispartof Blood purification, 2006-02, Vol.24 (2), p.222-229
issn 0253-5068
1421-9735
language eng
recordid cdi_karger_primary_91016
source Karger Journals
subjects Historical Perspectives
title Dialysis, Ultrafiltration, and Blood Pressure
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T11%3A53%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-karger_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dialysis,%20Ultrafiltration,%20and%20Blood%20Pressure&rft.jtitle=Blood%20purification&rft.au=Bergstr%C3%B6m,%20J.&rft.date=2006-02&rft.volume=24&rft.issue=2&rft.spage=222&rft.epage=229&rft.pages=222-229&rft.issn=0253-5068&rft.eissn=1421-9735&rft_id=info:doi/10.1159/000091016&rft_dat=%3Ckarger_cross%3E91016%3C/karger_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/16428879&rfr_iscdi=true