Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer

Abstract Objectives: The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any brea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta cytologica 2023-01, Vol.67 (1), p.1-16
Hauptverfasser: Paul, Pranoy, Azad, Shweta, Agrawal, Shruti, Rao, Shalinee, Chowdhury, Nilotpal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 16
container_issue 1
container_start_page 1
container_title Acta cytologica
container_volume 67
creator Paul, Pranoy
Azad, Shweta
Agrawal, Shruti
Rao, Shalinee
Chowdhury, Nilotpal
description Abstract Objectives: The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any breast lesion found suitable for FNAB. The target condition was breast cancer. The secondary objective was to study the proportion of inadequate FNAB in the selected studies. Methods: PubMed/MEDLINE and Embase were searched for studies having all the following key search terms: Breast AND FNAB AND Diagnostic Accuracy published in the time frame of 2017 to May 16, 2022. The Cochrane and PROSPERO databases, citations of selected articles and articles citing the selected articles were also searched. Studies assessing the diagnostic accuracy of breast FNAB in diagnosing breast cancer, which had at least 75 subjects (and at least 20 subjects each in the benign and malignant FNAB groups), were selected. The reference standard was histopathology (or adequate clinical follow-up for benign disease). Studies were screened independently by two researchers, with a consensus reached among the authors in cases of conflict. The risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity at each diagnostic cut-off were assessed by bivariate generalized linear mixed-model meta-analysis. The area under the receiver operating characteristics curve (AUC) and inadequacy rate were assessed by random-effects meta-analysis. The confidence intervals of sensitivity, specificity, and AUC were examined against a value of 0.95. Results: Twenty-two studies, all of which were cross-sectional single-gate studies, were selected with a total of 10,886 subjects with a primary breast lesion having concurrent FNAB and reference standard reports. Sensitivity and specificity, with 95% confidence intervals, were 0.978 [0.968, 0.985] and 0.832 [0.76, 0.886] for the diagnostic cut-off of “Atypical considered positive for malignancy,” 0.916 [0.892, 0.935] and 0.983 [0.97, 0.99] for the cut-off of “Suspicious of Malignancy considered positive,” and 0.763 [0.706, 0.812] and 0.999 [0.994, 1] for the cut-off of “Malignant considered positive.” The overall AUC was 0.975 [0.962, 0.984]. FNAB sampling without imaging guidance was associated with lower inadequacy. Discussion: There is strong evidence that the overall accuracy, sensitivity for “Atypical category considered positi
doi_str_mv 10.1159/000527346
format Article
fullrecord <record><control><sourceid>proquest_karge</sourceid><recordid>TN_cdi_karger_primary_527346</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2739067816</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-ce79669c9791db47407b651a8c49149d0abf3a2bb857871baf6adc0cd2ecb06b3</originalsourceid><addsrcrecordid>eNptkU9v1DAQxS0EokvhwB0hS1zgELDjxI6PaaBQqYDEn0NPkeNMtqaJHWwvKF-Qz4Xb7K44cBpp3m_eG-kh9JSS15SW8g0hpMwFK_g9tKGSVVnOS3IfbdKeZmVZiBP0KIQfhDDGOXuIThgvaF4KtkF_vi4hwqSi0fgL_DLwGyvb448QVVZbNS7BBOwGHK8BvzVqa124RWutd17p5SBd2AjeJheXbpKqepjuxGaJbnTbBV-5G3etJoXXQDw4nwJn56OxW3zmQYWIz42F7BNAPwKuw2z8nSM-M24OCzb28MI_J42yGvxj9GBQY4An-3mKvp-_-9Z8yC4_v79o6stMMy5jpkFIzqWWQtK-K0RBRMdLqipdSFrInqhuYCrvuqoUlaCdGrjqNdF9DrojvGOn6OXqO3v3cwchtpMJGsZRWXC70KYWJOGiojyhr1ZUexeCh6GdvZmUX1pK2tva2mNtiX2-t911E_RH8tBTAl6swI3yW_BHoG6uVot27odEPfsvtU_5C8QOqxU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2739067816</pqid></control><display><type>article</type><title>Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer</title><source>MEDLINE</source><source>Karger Journals Complete</source><creator>Paul, Pranoy ; Azad, Shweta ; Agrawal, Shruti ; Rao, Shalinee ; Chowdhury, Nilotpal</creator><creatorcontrib>Paul, Pranoy ; Azad, Shweta ; Agrawal, Shruti ; Rao, Shalinee ; Chowdhury, Nilotpal</creatorcontrib><description>Abstract Objectives: The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any breast lesion found suitable for FNAB. The target condition was breast cancer. The secondary objective was to study the proportion of inadequate FNAB in the selected studies. Methods: PubMed/MEDLINE and Embase were searched for studies having all the following key search terms: Breast AND FNAB AND Diagnostic Accuracy published in the time frame of 2017 to May 16, 2022. The Cochrane and PROSPERO databases, citations of selected articles and articles citing the selected articles were also searched. Studies assessing the diagnostic accuracy of breast FNAB in diagnosing breast cancer, which had at least 75 subjects (and at least 20 subjects each in the benign and malignant FNAB groups), were selected. The reference standard was histopathology (or adequate clinical follow-up for benign disease). Studies were screened independently by two researchers, with a consensus reached among the authors in cases of conflict. The risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity at each diagnostic cut-off were assessed by bivariate generalized linear mixed-model meta-analysis. The area under the receiver operating characteristics curve (AUC) and inadequacy rate were assessed by random-effects meta-analysis. The confidence intervals of sensitivity, specificity, and AUC were examined against a value of 0.95. Results: Twenty-two studies, all of which were cross-sectional single-gate studies, were selected with a total of 10,886 subjects with a primary breast lesion having concurrent FNAB and reference standard reports. Sensitivity and specificity, with 95% confidence intervals, were 0.978 [0.968, 0.985] and 0.832 [0.76, 0.886] for the diagnostic cut-off of “Atypical considered positive for malignancy,” 0.916 [0.892, 0.935] and 0.983 [0.97, 0.99] for the cut-off of “Suspicious of Malignancy considered positive,” and 0.763 [0.706, 0.812] and 0.999 [0.994, 1] for the cut-off of “Malignant considered positive.” The overall AUC was 0.975 [0.962, 0.984]. FNAB sampling without imaging guidance was associated with lower inadequacy. Discussion: There is strong evidence that the overall accuracy, sensitivity for “Atypical category considered positive” and specificity when “Suspicious or Malignant categories are considered positive” of FNAB are high when using the categories of the IAC Yokohama Reporting System, demonstrating the usefulness of FNAB in diagnosing breast cancer.</description><identifier>ISSN: 0001-5547</identifier><identifier>EISSN: 1938-2650</identifier><identifier>DOI: 10.1159/000527346</identifier><identifier>PMID: 36412573</identifier><language>eng</language><publisher>Basel, Switzerland</publisher><subject>Biopsy, Fine-Needle ; Breast - pathology ; Breast Neoplasms - diagnosis ; Breast Neoplasms - pathology ; Cytodiagnosis ; Cytological Techniques ; Female ; Fine Needle Aspiration ; Humans ; Sensitivity and Specificity</subject><ispartof>Acta cytologica, 2023-01, Vol.67 (1), p.1-16</ispartof><rights>2022 S. Karger AG, Basel</rights><rights>2022 S. Karger AG, Basel.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-ce79669c9791db47407b651a8c49149d0abf3a2bb857871baf6adc0cd2ecb06b3</citedby><orcidid>0000-0001-9280-5831 ; 0000-0003-2625-0799</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2429,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36412573$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Paul, Pranoy</creatorcontrib><creatorcontrib>Azad, Shweta</creatorcontrib><creatorcontrib>Agrawal, Shruti</creatorcontrib><creatorcontrib>Rao, Shalinee</creatorcontrib><creatorcontrib>Chowdhury, Nilotpal</creatorcontrib><title>Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer</title><title>Acta cytologica</title><addtitle>Acta Cytologica</addtitle><description>Abstract Objectives: The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any breast lesion found suitable for FNAB. The target condition was breast cancer. The secondary objective was to study the proportion of inadequate FNAB in the selected studies. Methods: PubMed/MEDLINE and Embase were searched for studies having all the following key search terms: Breast AND FNAB AND Diagnostic Accuracy published in the time frame of 2017 to May 16, 2022. The Cochrane and PROSPERO databases, citations of selected articles and articles citing the selected articles were also searched. Studies assessing the diagnostic accuracy of breast FNAB in diagnosing breast cancer, which had at least 75 subjects (and at least 20 subjects each in the benign and malignant FNAB groups), were selected. The reference standard was histopathology (or adequate clinical follow-up for benign disease). Studies were screened independently by two researchers, with a consensus reached among the authors in cases of conflict. The risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity at each diagnostic cut-off were assessed by bivariate generalized linear mixed-model meta-analysis. The area under the receiver operating characteristics curve (AUC) and inadequacy rate were assessed by random-effects meta-analysis. The confidence intervals of sensitivity, specificity, and AUC were examined against a value of 0.95. Results: Twenty-two studies, all of which were cross-sectional single-gate studies, were selected with a total of 10,886 subjects with a primary breast lesion having concurrent FNAB and reference standard reports. Sensitivity and specificity, with 95% confidence intervals, were 0.978 [0.968, 0.985] and 0.832 [0.76, 0.886] for the diagnostic cut-off of “Atypical considered positive for malignancy,” 0.916 [0.892, 0.935] and 0.983 [0.97, 0.99] for the cut-off of “Suspicious of Malignancy considered positive,” and 0.763 [0.706, 0.812] and 0.999 [0.994, 1] for the cut-off of “Malignant considered positive.” The overall AUC was 0.975 [0.962, 0.984]. FNAB sampling without imaging guidance was associated with lower inadequacy. Discussion: There is strong evidence that the overall accuracy, sensitivity for “Atypical category considered positive” and specificity when “Suspicious or Malignant categories are considered positive” of FNAB are high when using the categories of the IAC Yokohama Reporting System, demonstrating the usefulness of FNAB in diagnosing breast cancer.</description><subject>Biopsy, Fine-Needle</subject><subject>Breast - pathology</subject><subject>Breast Neoplasms - diagnosis</subject><subject>Breast Neoplasms - pathology</subject><subject>Cytodiagnosis</subject><subject>Cytological Techniques</subject><subject>Female</subject><subject>Fine Needle Aspiration</subject><subject>Humans</subject><subject>Sensitivity and Specificity</subject><issn>0001-5547</issn><issn>1938-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkU9v1DAQxS0EokvhwB0hS1zgELDjxI6PaaBQqYDEn0NPkeNMtqaJHWwvKF-Qz4Xb7K44cBpp3m_eG-kh9JSS15SW8g0hpMwFK_g9tKGSVVnOS3IfbdKeZmVZiBP0KIQfhDDGOXuIThgvaF4KtkF_vi4hwqSi0fgL_DLwGyvb448QVVZbNS7BBOwGHK8BvzVqa124RWutd17p5SBd2AjeJheXbpKqepjuxGaJbnTbBV-5G3etJoXXQDw4nwJn56OxW3zmQYWIz42F7BNAPwKuw2z8nSM-M24OCzb28MI_J42yGvxj9GBQY4An-3mKvp-_-9Z8yC4_v79o6stMMy5jpkFIzqWWQtK-K0RBRMdLqipdSFrInqhuYCrvuqoUlaCdGrjqNdF9DrojvGOn6OXqO3v3cwchtpMJGsZRWXC70KYWJOGiojyhr1ZUexeCh6GdvZmUX1pK2tva2mNtiX2-t911E_RH8tBTAl6swI3yW_BHoG6uVot27odEPfsvtU_5C8QOqxU</recordid><startdate>202301</startdate><enddate>202301</enddate><creator>Paul, Pranoy</creator><creator>Azad, Shweta</creator><creator>Agrawal, Shruti</creator><creator>Rao, Shalinee</creator><creator>Chowdhury, Nilotpal</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9280-5831</orcidid><orcidid>https://orcid.org/0000-0003-2625-0799</orcidid></search><sort><creationdate>202301</creationdate><title>Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer</title><author>Paul, Pranoy ; Azad, Shweta ; Agrawal, Shruti ; Rao, Shalinee ; Chowdhury, Nilotpal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-ce79669c9791db47407b651a8c49149d0abf3a2bb857871baf6adc0cd2ecb06b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Biopsy, Fine-Needle</topic><topic>Breast - pathology</topic><topic>Breast Neoplasms - diagnosis</topic><topic>Breast Neoplasms - pathology</topic><topic>Cytodiagnosis</topic><topic>Cytological Techniques</topic><topic>Female</topic><topic>Fine Needle Aspiration</topic><topic>Humans</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Paul, Pranoy</creatorcontrib><creatorcontrib>Azad, Shweta</creatorcontrib><creatorcontrib>Agrawal, Shruti</creatorcontrib><creatorcontrib>Rao, Shalinee</creatorcontrib><creatorcontrib>Chowdhury, Nilotpal</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta cytologica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Paul, Pranoy</au><au>Azad, Shweta</au><au>Agrawal, Shruti</au><au>Rao, Shalinee</au><au>Chowdhury, Nilotpal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer</atitle><jtitle>Acta cytologica</jtitle><addtitle>Acta Cytologica</addtitle><date>2023-01</date><risdate>2023</risdate><volume>67</volume><issue>1</issue><spage>1</spage><epage>16</epage><pages>1-16</pages><issn>0001-5547</issn><eissn>1938-2650</eissn><abstract>Abstract Objectives: The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any breast lesion found suitable for FNAB. The target condition was breast cancer. The secondary objective was to study the proportion of inadequate FNAB in the selected studies. Methods: PubMed/MEDLINE and Embase were searched for studies having all the following key search terms: Breast AND FNAB AND Diagnostic Accuracy published in the time frame of 2017 to May 16, 2022. The Cochrane and PROSPERO databases, citations of selected articles and articles citing the selected articles were also searched. Studies assessing the diagnostic accuracy of breast FNAB in diagnosing breast cancer, which had at least 75 subjects (and at least 20 subjects each in the benign and malignant FNAB groups), were selected. The reference standard was histopathology (or adequate clinical follow-up for benign disease). Studies were screened independently by two researchers, with a consensus reached among the authors in cases of conflict. The risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity at each diagnostic cut-off were assessed by bivariate generalized linear mixed-model meta-analysis. The area under the receiver operating characteristics curve (AUC) and inadequacy rate were assessed by random-effects meta-analysis. The confidence intervals of sensitivity, specificity, and AUC were examined against a value of 0.95. Results: Twenty-two studies, all of which were cross-sectional single-gate studies, were selected with a total of 10,886 subjects with a primary breast lesion having concurrent FNAB and reference standard reports. Sensitivity and specificity, with 95% confidence intervals, were 0.978 [0.968, 0.985] and 0.832 [0.76, 0.886] for the diagnostic cut-off of “Atypical considered positive for malignancy,” 0.916 [0.892, 0.935] and 0.983 [0.97, 0.99] for the cut-off of “Suspicious of Malignancy considered positive,” and 0.763 [0.706, 0.812] and 0.999 [0.994, 1] for the cut-off of “Malignant considered positive.” The overall AUC was 0.975 [0.962, 0.984]. FNAB sampling without imaging guidance was associated with lower inadequacy. Discussion: There is strong evidence that the overall accuracy, sensitivity for “Atypical category considered positive” and specificity when “Suspicious or Malignant categories are considered positive” of FNAB are high when using the categories of the IAC Yokohama Reporting System, demonstrating the usefulness of FNAB in diagnosing breast cancer.</abstract><cop>Basel, Switzerland</cop><pmid>36412573</pmid><doi>10.1159/000527346</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0001-9280-5831</orcidid><orcidid>https://orcid.org/0000-0003-2625-0799</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0001-5547
ispartof Acta cytologica, 2023-01, Vol.67 (1), p.1-16
issn 0001-5547
1938-2650
language eng
recordid cdi_karger_primary_527346
source MEDLINE; Karger Journals Complete
subjects Biopsy, Fine-Needle
Breast - pathology
Breast Neoplasms - diagnosis
Breast Neoplasms - pathology
Cytodiagnosis
Cytological Techniques
Female
Fine Needle Aspiration
Humans
Sensitivity and Specificity
title Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T22%3A24%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_karge&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Systematic%20Review%20and%20Meta-Analysis%20of%20the%20Diagnostic%20Accuracy%20of%20the%20International%20Academy%20of%20Cytology%20Yokohama%20System%20for%20Reporting%20Breast%20Fine-Needle%20Aspiration%20Biopsy%20in%20Diagnosing%20Breast%20Cancer&rft.jtitle=Acta%20cytologica&rft.au=Paul,%20Pranoy&rft.date=2023-01&rft.volume=67&rft.issue=1&rft.spage=1&rft.epage=16&rft.pages=1-16&rft.issn=0001-5547&rft.eissn=1938-2650&rft_id=info:doi/10.1159/000527346&rft_dat=%3Cproquest_karge%3E2739067816%3C/proquest_karge%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2739067816&rft_id=info:pmid/36412573&rfr_iscdi=true