Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion

The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ECS transactions 2018-01, Vol.86 (13), p.407-419
Hauptverfasser: Banas, Charles Joseph, Arman, Md. Tanvir Alam, Uddin, Md Aman, Park, Jaehyung, Bonville, Leonard J., Pasaogullari, Ugur
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 419
container_issue 13
container_start_page 407
container_title ECS transactions
container_volume 86
creator Banas, Charles Joseph
Arman, Md. Tanvir Alam
Uddin, Md Aman
Park, Jaehyung
Bonville, Leonard J.
Pasaogullari, Ugur
description The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.
doi_str_mv 10.1149/08613.0407ecst
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1149_08613_0407ecst</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10.1149/08613.0407ecst</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</originalsourceid><addsrcrecordid>eNp1ULFOwzAQtRBIlMLK7BmRYDeO7YwobQGpEh1gjtzk3KZy4-riDP17TFpGpnv37r270yPkkbOUc1G8MC15ljLBFNR9uCITXmQ6kSpT1xecazm7JXd9v2dMRo-akGHt3ekASBcO6oCxCUCXAzhagnN0Dls0jQmt72jYoR-2O7r0CO22o-WZLn0XzKHtxu6ZrtGHyM7h6GCcm66JUtyMUkTfR_Ke3Fjjeni41Cn5Xi6-yvdk9fn2Ub6ukjrjPCRQ26a2GaiZsbwolC1ksTHSarHJBZhGgJCQG6OZmkkhgOtc60znoIzORYRTkp731vFuj2CrI7YHg6eKs-o3tGoMrfoLLRqezobWH6u9H7CL7_0n_gHC0G__</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</creator><creatorcontrib>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</creatorcontrib><description>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</description><identifier>ISSN: 1938-5862</identifier><identifier>ISSN: 1938-6737</identifier><identifier>EISSN: 1938-6737</identifier><identifier>EISSN: 1938-5862</identifier><identifier>DOI: 10.1149/08613.0407ecst</identifier><language>eng</language><publisher>The Electrochemical Society, Inc</publisher><ispartof>ECS transactions, 2018-01, Vol.86 (13), p.407-419</ispartof><rights>2018 ECS - The Electrochemical Society</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1149/08613.0407ecst/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Banas, Charles Joseph</creatorcontrib><creatorcontrib>Arman, Md. Tanvir Alam</creatorcontrib><creatorcontrib>Uddin, Md Aman</creatorcontrib><creatorcontrib>Park, Jaehyung</creatorcontrib><creatorcontrib>Bonville, Leonard J.</creatorcontrib><creatorcontrib>Pasaogullari, Ugur</creatorcontrib><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><title>ECS transactions</title><addtitle>ECS Trans</addtitle><description>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</description><issn>1938-5862</issn><issn>1938-6737</issn><issn>1938-6737</issn><issn>1938-5862</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1ULFOwzAQtRBIlMLK7BmRYDeO7YwobQGpEh1gjtzk3KZy4-riDP17TFpGpnv37r270yPkkbOUc1G8MC15ljLBFNR9uCITXmQ6kSpT1xecazm7JXd9v2dMRo-akGHt3ekASBcO6oCxCUCXAzhagnN0Dls0jQmt72jYoR-2O7r0CO22o-WZLn0XzKHtxu6ZrtGHyM7h6GCcm66JUtyMUkTfR_Ke3Fjjeni41Cn5Xi6-yvdk9fn2Ub6ukjrjPCRQ26a2GaiZsbwolC1ksTHSarHJBZhGgJCQG6OZmkkhgOtc60znoIzORYRTkp731vFuj2CrI7YHg6eKs-o3tGoMrfoLLRqezobWH6u9H7CL7_0n_gHC0G__</recordid><startdate>20180101</startdate><enddate>20180101</enddate><creator>Banas, Charles Joseph</creator><creator>Arman, Md. Tanvir Alam</creator><creator>Uddin, Md Aman</creator><creator>Park, Jaehyung</creator><creator>Bonville, Leonard J.</creator><creator>Pasaogullari, Ugur</creator><general>The Electrochemical Society, Inc</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20180101</creationdate><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><author>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Banas, Charles Joseph</creatorcontrib><creatorcontrib>Arman, Md. Tanvir Alam</creatorcontrib><creatorcontrib>Uddin, Md Aman</creatorcontrib><creatorcontrib>Park, Jaehyung</creatorcontrib><creatorcontrib>Bonville, Leonard J.</creatorcontrib><creatorcontrib>Pasaogullari, Ugur</creatorcontrib><collection>CrossRef</collection><jtitle>ECS transactions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Banas, Charles Joseph</au><au>Arman, Md. Tanvir Alam</au><au>Uddin, Md Aman</au><au>Park, Jaehyung</au><au>Bonville, Leonard J.</au><au>Pasaogullari, Ugur</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</atitle><jtitle>ECS transactions</jtitle><addtitle>ECS Trans</addtitle><date>2018-01-01</date><risdate>2018</risdate><volume>86</volume><issue>13</issue><spage>407</spage><epage>419</epage><pages>407-419</pages><issn>1938-5862</issn><issn>1938-6737</issn><eissn>1938-6737</eissn><eissn>1938-5862</eissn><abstract>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</abstract><pub>The Electrochemical Society, Inc</pub><doi>10.1149/08613.0407ecst</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1938-5862
ispartof ECS transactions, 2018-01, Vol.86 (13), p.407-419
issn 1938-5862
1938-6737
1938-6737
1938-5862
language eng
recordid cdi_iop_journals_10_1149_08613_0407ecst
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
title Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A39%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Polymer%20Electrolyte%20Fuel%20Cell%20Degradation%20through%20Foreign%20Cation%20Contamination,%20Proton%20Depletion%20and%20Carbon%20Corrosion&rft.jtitle=ECS%20transactions&rft.au=Banas,%20Charles%20Joseph&rft.date=2018-01-01&rft.volume=86&rft.issue=13&rft.spage=407&rft.epage=419&rft.pages=407-419&rft.issn=1938-5862&rft.eissn=1938-6737&rft_id=info:doi/10.1149/08613.0407ecst&rft_dat=%3Ciop_cross%3E10.1149/08613.0407ecst%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true