Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion
The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decre...
Gespeichert in:
Veröffentlicht in: | ECS transactions 2018-01, Vol.86 (13), p.407-419 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 419 |
---|---|
container_issue | 13 |
container_start_page | 407 |
container_title | ECS transactions |
container_volume | 86 |
creator | Banas, Charles Joseph Arman, Md. Tanvir Alam Uddin, Md Aman Park, Jaehyung Bonville, Leonard J. Pasaogullari, Ugur |
description | The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters. |
doi_str_mv | 10.1149/08613.0407ecst |
format | Article |
fullrecord | <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1149_08613_0407ecst</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10.1149/08613.0407ecst</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</originalsourceid><addsrcrecordid>eNp1ULFOwzAQtRBIlMLK7BmRYDeO7YwobQGpEh1gjtzk3KZy4-riDP17TFpGpnv37r270yPkkbOUc1G8MC15ljLBFNR9uCITXmQ6kSpT1xecazm7JXd9v2dMRo-akGHt3ekASBcO6oCxCUCXAzhagnN0Dls0jQmt72jYoR-2O7r0CO22o-WZLn0XzKHtxu6ZrtGHyM7h6GCcm66JUtyMUkTfR_Ke3Fjjeni41Cn5Xi6-yvdk9fn2Ub6ukjrjPCRQ26a2GaiZsbwolC1ksTHSarHJBZhGgJCQG6OZmkkhgOtc60znoIzORYRTkp731vFuj2CrI7YHg6eKs-o3tGoMrfoLLRqezobWH6u9H7CL7_0n_gHC0G__</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</creator><creatorcontrib>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</creatorcontrib><description>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</description><identifier>ISSN: 1938-5862</identifier><identifier>ISSN: 1938-6737</identifier><identifier>EISSN: 1938-6737</identifier><identifier>EISSN: 1938-5862</identifier><identifier>DOI: 10.1149/08613.0407ecst</identifier><language>eng</language><publisher>The Electrochemical Society, Inc</publisher><ispartof>ECS transactions, 2018-01, Vol.86 (13), p.407-419</ispartof><rights>2018 ECS - The Electrochemical Society</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1149/08613.0407ecst/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Banas, Charles Joseph</creatorcontrib><creatorcontrib>Arman, Md. Tanvir Alam</creatorcontrib><creatorcontrib>Uddin, Md Aman</creatorcontrib><creatorcontrib>Park, Jaehyung</creatorcontrib><creatorcontrib>Bonville, Leonard J.</creatorcontrib><creatorcontrib>Pasaogullari, Ugur</creatorcontrib><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><title>ECS transactions</title><addtitle>ECS Trans</addtitle><description>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</description><issn>1938-5862</issn><issn>1938-6737</issn><issn>1938-6737</issn><issn>1938-5862</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1ULFOwzAQtRBIlMLK7BmRYDeO7YwobQGpEh1gjtzk3KZy4-riDP17TFpGpnv37r270yPkkbOUc1G8MC15ljLBFNR9uCITXmQ6kSpT1xecazm7JXd9v2dMRo-akGHt3ekASBcO6oCxCUCXAzhagnN0Dls0jQmt72jYoR-2O7r0CO22o-WZLn0XzKHtxu6ZrtGHyM7h6GCcm66JUtyMUkTfR_Ke3Fjjeni41Cn5Xi6-yvdk9fn2Ub6ukjrjPCRQ26a2GaiZsbwolC1ksTHSarHJBZhGgJCQG6OZmkkhgOtc60znoIzORYRTkp731vFuj2CrI7YHg6eKs-o3tGoMrfoLLRqezobWH6u9H7CL7_0n_gHC0G__</recordid><startdate>20180101</startdate><enddate>20180101</enddate><creator>Banas, Charles Joseph</creator><creator>Arman, Md. Tanvir Alam</creator><creator>Uddin, Md Aman</creator><creator>Park, Jaehyung</creator><creator>Bonville, Leonard J.</creator><creator>Pasaogullari, Ugur</creator><general>The Electrochemical Society, Inc</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20180101</creationdate><title>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</title><author>Banas, Charles Joseph ; Arman, Md. Tanvir Alam ; Uddin, Md Aman ; Park, Jaehyung ; Bonville, Leonard J. ; Pasaogullari, Ugur</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-ecfdcf3e72af1997f969ba6f84b54ead4e46e5aa8072644e18588385e7a854883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Banas, Charles Joseph</creatorcontrib><creatorcontrib>Arman, Md. Tanvir Alam</creatorcontrib><creatorcontrib>Uddin, Md Aman</creatorcontrib><creatorcontrib>Park, Jaehyung</creatorcontrib><creatorcontrib>Bonville, Leonard J.</creatorcontrib><creatorcontrib>Pasaogullari, Ugur</creatorcontrib><collection>CrossRef</collection><jtitle>ECS transactions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Banas, Charles Joseph</au><au>Arman, Md. Tanvir Alam</au><au>Uddin, Md Aman</au><au>Park, Jaehyung</au><au>Bonville, Leonard J.</au><au>Pasaogullari, Ugur</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion</atitle><jtitle>ECS transactions</jtitle><addtitle>ECS Trans</addtitle><date>2018-01-01</date><risdate>2018</risdate><volume>86</volume><issue>13</issue><spage>407</spage><epage>419</epage><pages>407-419</pages><issn>1938-5862</issn><issn>1938-6737</issn><eissn>1938-6737</eissn><eissn>1938-5862</eissn><abstract>The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.</abstract><pub>The Electrochemical Society, Inc</pub><doi>10.1149/08613.0407ecst</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1938-5862 |
ispartof | ECS transactions, 2018-01, Vol.86 (13), p.407-419 |
issn | 1938-5862 1938-6737 1938-6737 1938-5862 |
language | eng |
recordid | cdi_iop_journals_10_1149_08613_0407ecst |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
title | Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A39%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Polymer%20Electrolyte%20Fuel%20Cell%20Degradation%20through%20Foreign%20Cation%20Contamination,%20Proton%20Depletion%20and%20Carbon%20Corrosion&rft.jtitle=ECS%20transactions&rft.au=Banas,%20Charles%20Joseph&rft.date=2018-01-01&rft.volume=86&rft.issue=13&rft.spage=407&rft.epage=419&rft.pages=407-419&rft.issn=1938-5862&rft.eissn=1938-6737&rft_id=info:doi/10.1149/08613.0407ecst&rft_dat=%3Ciop_cross%3E10.1149/08613.0407ecst%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |