In-vitro validation of MR-based fat quantification at 1.5 T

Introduction: MRI is an emerging method in obesity research for the quantification of fat content in various body regions. The aim of this study was to determine the accuracy of MR fat-water imaging and MR spectroscopy for fat quantification at 1.5 T in oil-in-water phantoms. Material and Methods: O...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical physics & engineering express 2018-10, Vol.4 (6), p.67004
Hauptverfasser: Linder, N, Rakete, T, Stange, R, Solty, K, Kahn, T, Busse, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 6
container_start_page 67004
container_title Biomedical physics & engineering express
container_volume 4
creator Linder, N
Rakete, T
Stange, R
Solty, K
Kahn, T
Busse, H
description Introduction: MRI is an emerging method in obesity research for the quantification of fat content in various body regions. The aim of this study was to determine the accuracy of MR fat-water imaging and MR spectroscopy for fat quantification at 1.5 T in oil-in-water phantoms. Material and Methods: Oil-in-water emulsions were fabricated over the entire range of lipid content (0%-100%). Relative lipid content was then assessed by two-point Dixon MRI, multi-echo Dixon MRI and single-voxel proton MR spectroscopy (SV-MRS) with localization by both stimulated echo acquisition (STEAM) and point-resolved spectroscopy (PRESS). Linear regression and Bland-Altman analyses were used for statistical evaluation of the results. Results: Agreement between MR-derived measures of lipid content and nominal values in phantoms was generally good. Agreement for two-point Dixon was moderate only (R2 = 0.75) here, especially for lipid contents between 30% and 70%. For multi-echo Dixon, STEAM and PRESS MRS, the coefficients of determination were very high (rounded R2 = 0.98 for all). Discussion: In conclusion, this work complements previous studies of MR-based fat quantification at 1.5 T and shows that multi-echo Dixon MRI and MR spectroscopy provide close results over the full range of lipid contents.
doi_str_mv 10.1088/2057-1976/aae646
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1088_2057_1976_aae646</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>bpexaae646</sourcerecordid><originalsourceid>FETCH-LOGICAL-c180t-d32a5026172638ad5f388131bec33dc6e77a30ced302adecbe07b4e13ffba7b43</originalsourceid><addsrcrecordid>eNp9j81Lw0AQxRdRsNTePebmxW1nd5PdLZ6k-FGoCFLPy-wXbKlJTNKi_70JEfEgnubx5r1hfoRcMpgz0HrBoVCULZVcIAaZyxMy-bFOf-lzMmvbHQAwyaVcFhNysy7pMXVNlR1xnzx2qSqzKmZPL9RiG3wWscveD1h2KSY3rnuHzYtse0HOIu7bMPueU_J6f7ddPdLN88N6dbuhjmnoqBccC-CSKS6FRl9EoTUTzAYnhHcyKIUCXPACOPrgbABl88BEjBZ7JaYExruuqdq2CdHUTXrD5tMwMAO_GQDNAGhG_r5yPVZSVZtddWjK_sH_4ld_xG0dPkxupAGpAHJT-yi-AMUXaCY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>In-vitro validation of MR-based fat quantification at 1.5 T</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Linder, N ; Rakete, T ; Stange, R ; Solty, K ; Kahn, T ; Busse, H</creator><creatorcontrib>Linder, N ; Rakete, T ; Stange, R ; Solty, K ; Kahn, T ; Busse, H</creatorcontrib><description>Introduction: MRI is an emerging method in obesity research for the quantification of fat content in various body regions. The aim of this study was to determine the accuracy of MR fat-water imaging and MR spectroscopy for fat quantification at 1.5 T in oil-in-water phantoms. Material and Methods: Oil-in-water emulsions were fabricated over the entire range of lipid content (0%-100%). Relative lipid content was then assessed by two-point Dixon MRI, multi-echo Dixon MRI and single-voxel proton MR spectroscopy (SV-MRS) with localization by both stimulated echo acquisition (STEAM) and point-resolved spectroscopy (PRESS). Linear regression and Bland-Altman analyses were used for statistical evaluation of the results. Results: Agreement between MR-derived measures of lipid content and nominal values in phantoms was generally good. Agreement for two-point Dixon was moderate only (R2 = 0.75) here, especially for lipid contents between 30% and 70%. For multi-echo Dixon, STEAM and PRESS MRS, the coefficients of determination were very high (rounded R2 = 0.98 for all). Discussion: In conclusion, this work complements previous studies of MR-based fat quantification at 1.5 T and shows that multi-echo Dixon MRI and MR spectroscopy provide close results over the full range of lipid contents.</description><identifier>ISSN: 2057-1976</identifier><identifier>EISSN: 2057-1976</identifier><identifier>DOI: 10.1088/2057-1976/aae646</identifier><identifier>CODEN: NJOPFM</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>fat-quantification ; multi-echo Dixon ; single voxel MR spectroscopy</subject><ispartof>Biomedical physics &amp; engineering express, 2018-10, Vol.4 (6), p.67004</ispartof><rights>2018 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c180t-d32a5026172638ad5f388131bec33dc6e77a30ced302adecbe07b4e13ffba7b43</cites><orcidid>0000-0003-2816-8158</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/2057-1976/aae646/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Linder, N</creatorcontrib><creatorcontrib>Rakete, T</creatorcontrib><creatorcontrib>Stange, R</creatorcontrib><creatorcontrib>Solty, K</creatorcontrib><creatorcontrib>Kahn, T</creatorcontrib><creatorcontrib>Busse, H</creatorcontrib><title>In-vitro validation of MR-based fat quantification at 1.5 T</title><title>Biomedical physics &amp; engineering express</title><addtitle>BPEX</addtitle><addtitle>Biomed. Phys. Eng. Express</addtitle><description>Introduction: MRI is an emerging method in obesity research for the quantification of fat content in various body regions. The aim of this study was to determine the accuracy of MR fat-water imaging and MR spectroscopy for fat quantification at 1.5 T in oil-in-water phantoms. Material and Methods: Oil-in-water emulsions were fabricated over the entire range of lipid content (0%-100%). Relative lipid content was then assessed by two-point Dixon MRI, multi-echo Dixon MRI and single-voxel proton MR spectroscopy (SV-MRS) with localization by both stimulated echo acquisition (STEAM) and point-resolved spectroscopy (PRESS). Linear regression and Bland-Altman analyses were used for statistical evaluation of the results. Results: Agreement between MR-derived measures of lipid content and nominal values in phantoms was generally good. Agreement for two-point Dixon was moderate only (R2 = 0.75) here, especially for lipid contents between 30% and 70%. For multi-echo Dixon, STEAM and PRESS MRS, the coefficients of determination were very high (rounded R2 = 0.98 for all). Discussion: In conclusion, this work complements previous studies of MR-based fat quantification at 1.5 T and shows that multi-echo Dixon MRI and MR spectroscopy provide close results over the full range of lipid contents.</description><subject>fat-quantification</subject><subject>multi-echo Dixon</subject><subject>single voxel MR spectroscopy</subject><issn>2057-1976</issn><issn>2057-1976</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9j81Lw0AQxRdRsNTePebmxW1nd5PdLZ6k-FGoCFLPy-wXbKlJTNKi_70JEfEgnubx5r1hfoRcMpgz0HrBoVCULZVcIAaZyxMy-bFOf-lzMmvbHQAwyaVcFhNysy7pMXVNlR1xnzx2qSqzKmZPL9RiG3wWscveD1h2KSY3rnuHzYtse0HOIu7bMPueU_J6f7ddPdLN88N6dbuhjmnoqBccC-CSKS6FRl9EoTUTzAYnhHcyKIUCXPACOPrgbABl88BEjBZ7JaYExruuqdq2CdHUTXrD5tMwMAO_GQDNAGhG_r5yPVZSVZtddWjK_sH_4ld_xG0dPkxupAGpAHJT-yi-AMUXaCY</recordid><startdate>20181025</startdate><enddate>20181025</enddate><creator>Linder, N</creator><creator>Rakete, T</creator><creator>Stange, R</creator><creator>Solty, K</creator><creator>Kahn, T</creator><creator>Busse, H</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-2816-8158</orcidid></search><sort><creationdate>20181025</creationdate><title>In-vitro validation of MR-based fat quantification at 1.5 T</title><author>Linder, N ; Rakete, T ; Stange, R ; Solty, K ; Kahn, T ; Busse, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c180t-d32a5026172638ad5f388131bec33dc6e77a30ced302adecbe07b4e13ffba7b43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>fat-quantification</topic><topic>multi-echo Dixon</topic><topic>single voxel MR spectroscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Linder, N</creatorcontrib><creatorcontrib>Rakete, T</creatorcontrib><creatorcontrib>Stange, R</creatorcontrib><creatorcontrib>Solty, K</creatorcontrib><creatorcontrib>Kahn, T</creatorcontrib><creatorcontrib>Busse, H</creatorcontrib><collection>CrossRef</collection><jtitle>Biomedical physics &amp; engineering express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Linder, N</au><au>Rakete, T</au><au>Stange, R</au><au>Solty, K</au><au>Kahn, T</au><au>Busse, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In-vitro validation of MR-based fat quantification at 1.5 T</atitle><jtitle>Biomedical physics &amp; engineering express</jtitle><stitle>BPEX</stitle><addtitle>Biomed. Phys. Eng. Express</addtitle><date>2018-10-25</date><risdate>2018</risdate><volume>4</volume><issue>6</issue><spage>67004</spage><pages>67004-</pages><issn>2057-1976</issn><eissn>2057-1976</eissn><coden>NJOPFM</coden><abstract>Introduction: MRI is an emerging method in obesity research for the quantification of fat content in various body regions. The aim of this study was to determine the accuracy of MR fat-water imaging and MR spectroscopy for fat quantification at 1.5 T in oil-in-water phantoms. Material and Methods: Oil-in-water emulsions were fabricated over the entire range of lipid content (0%-100%). Relative lipid content was then assessed by two-point Dixon MRI, multi-echo Dixon MRI and single-voxel proton MR spectroscopy (SV-MRS) with localization by both stimulated echo acquisition (STEAM) and point-resolved spectroscopy (PRESS). Linear regression and Bland-Altman analyses were used for statistical evaluation of the results. Results: Agreement between MR-derived measures of lipid content and nominal values in phantoms was generally good. Agreement for two-point Dixon was moderate only (R2 = 0.75) here, especially for lipid contents between 30% and 70%. For multi-echo Dixon, STEAM and PRESS MRS, the coefficients of determination were very high (rounded R2 = 0.98 for all). Discussion: In conclusion, this work complements previous studies of MR-based fat quantification at 1.5 T and shows that multi-echo Dixon MRI and MR spectroscopy provide close results over the full range of lipid contents.</abstract><pub>IOP Publishing</pub><doi>10.1088/2057-1976/aae646</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-2816-8158</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2057-1976
ispartof Biomedical physics & engineering express, 2018-10, Vol.4 (6), p.67004
issn 2057-1976
2057-1976
language eng
recordid cdi_iop_journals_10_1088_2057_1976_aae646
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects fat-quantification
multi-echo Dixon
single voxel MR spectroscopy
title In-vitro validation of MR-based fat quantification at 1.5 T
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T20%3A41%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In-vitro%20validation%20of%20MR-based%20fat%20quantification%20at%201.5%20T&rft.jtitle=Biomedical%20physics%20&%20engineering%20express&rft.au=Linder,%20N&rft.date=2018-10-25&rft.volume=4&rft.issue=6&rft.spage=67004&rft.pages=67004-&rft.issn=2057-1976&rft.eissn=2057-1976&rft.coden=NJOPFM&rft_id=info:doi/10.1088/2057-1976/aae646&rft_dat=%3Ciop_cross%3Ebpexaae646%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true