First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak

A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument functio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plasma physics and controlled fusion 2017-10, Vol.59 (10), p.105009
Hauptverfasser: Rodriguez-Ramos, M, Garcia-Munoz, M, Jimenez-Ramos, M C, Lopez, J Garcia, Galdon-Quiroga, J, Sanchis-Sanchez, L, Ayllon-Guerola, J, Faitsch, M, Gonzalez-Martin, J, Hermann, A, Marne, P de, Rivero-Rodriguez, J F, Sieglin, B, Snicker, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 10
container_start_page 105009
container_title Plasma physics and controlled fusion
container_volume 59
creator Rodriguez-Ramos, M
Garcia-Munoz, M
Jimenez-Ramos, M C
Lopez, J Garcia
Galdon-Quiroga, J
Sanchis-Sanchez, L
Ayllon-Guerola, J
Faitsch, M
Gonzalez-Martin, J
Hermann, A
Marne, P de
Rivero-Rodriguez, J F
Sieglin, B
Snicker, A
description A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.
doi_str_mv 10.1088/1361-6587/aa7e5f
format Article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6587_aa7e5f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ppcfaa7e5f</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-f5cef9469ce6f3b4ee0505244911db7585bacb30a329b86b56344c6c78ef11643</originalsourceid><addsrcrecordid>eNp1kM1LAzEUxIMoWKt3j7kKrk2aj80eS21VLHjQgreQpC-6bXezJOnB_94uK5709OAxv2FmELqm5I4SpSaUSVpIocqJMSUIf4JGv69TNCIlpwVjTJyji5S2hFCqpnKEnpd1TBkbm8L-kAE3YNIhQgNtTjh47E3KRR1avA8pQcJ1i_Mn4Nnr_eIdr7uPaDaAc9iZxuwu0Zk3-wRXP3eM1svF2_yxWL08PM1nq8IxIXPhhQNfcVk5kJ5ZDkAEEVPOK0o3thRKWOMsI4ZNK6ukFZJx7qQrFXhKJWdjRAZfF4-hInjdxbox8UtTovsxdN9c9831MMYRuRmQOnR6Gw6xPQbUXee8FtWACUIq3W167e0f2n-tvwHeqG6M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Rodriguez-Ramos, M ; Garcia-Munoz, M ; Jimenez-Ramos, M C ; Lopez, J Garcia ; Galdon-Quiroga, J ; Sanchis-Sanchez, L ; Ayllon-Guerola, J ; Faitsch, M ; Gonzalez-Martin, J ; Hermann, A ; Marne, P de ; Rivero-Rodriguez, J F ; Sieglin, B ; Snicker, A</creator><creatorcontrib>Rodriguez-Ramos, M ; Garcia-Munoz, M ; Jimenez-Ramos, M C ; Lopez, J Garcia ; Galdon-Quiroga, J ; Sanchis-Sanchez, L ; Ayllon-Guerola, J ; Faitsch, M ; Gonzalez-Martin, J ; Hermann, A ; Marne, P de ; Rivero-Rodriguez, J F ; Sieglin, B ; Snicker, A ; the ASDEX Upgrade Team</creatorcontrib><description>A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.</description><identifier>ISSN: 0741-3335</identifier><identifier>EISSN: 1361-6587</identifier><identifier>DOI: 10.1088/1361-6587/aa7e5f</identifier><identifier>CODEN: PLPHBZ</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>absolute flux ; fast-ion ; fast-ion loss detector ; ionoluminescence</subject><ispartof>Plasma physics and controlled fusion, 2017-10, Vol.59 (10), p.105009</ispartof><rights>2017 Max-Planck-Institut fur Plasmaphysik</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-f5cef9469ce6f3b4ee0505244911db7585bacb30a329b86b56344c6c78ef11643</citedby><cites>FETCH-LOGICAL-c356t-f5cef9469ce6f3b4ee0505244911db7585bacb30a329b86b56344c6c78ef11643</cites><orcidid>0000-0001-8127-3921</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6587/aa7e5f/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids></links><search><creatorcontrib>Rodriguez-Ramos, M</creatorcontrib><creatorcontrib>Garcia-Munoz, M</creatorcontrib><creatorcontrib>Jimenez-Ramos, M C</creatorcontrib><creatorcontrib>Lopez, J Garcia</creatorcontrib><creatorcontrib>Galdon-Quiroga, J</creatorcontrib><creatorcontrib>Sanchis-Sanchez, L</creatorcontrib><creatorcontrib>Ayllon-Guerola, J</creatorcontrib><creatorcontrib>Faitsch, M</creatorcontrib><creatorcontrib>Gonzalez-Martin, J</creatorcontrib><creatorcontrib>Hermann, A</creatorcontrib><creatorcontrib>Marne, P de</creatorcontrib><creatorcontrib>Rivero-Rodriguez, J F</creatorcontrib><creatorcontrib>Sieglin, B</creatorcontrib><creatorcontrib>Snicker, A</creatorcontrib><creatorcontrib>the ASDEX Upgrade Team</creatorcontrib><title>First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak</title><title>Plasma physics and controlled fusion</title><addtitle>PPCF</addtitle><addtitle>Plasma Phys. Control. Fusion</addtitle><description>A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.</description><subject>absolute flux</subject><subject>fast-ion</subject><subject>fast-ion loss detector</subject><subject>ionoluminescence</subject><issn>0741-3335</issn><issn>1361-6587</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kM1LAzEUxIMoWKt3j7kKrk2aj80eS21VLHjQgreQpC-6bXezJOnB_94uK5709OAxv2FmELqm5I4SpSaUSVpIocqJMSUIf4JGv69TNCIlpwVjTJyji5S2hFCqpnKEnpd1TBkbm8L-kAE3YNIhQgNtTjh47E3KRR1avA8pQcJ1i_Mn4Nnr_eIdr7uPaDaAc9iZxuwu0Zk3-wRXP3eM1svF2_yxWL08PM1nq8IxIXPhhQNfcVk5kJ5ZDkAEEVPOK0o3thRKWOMsI4ZNK6ukFZJx7qQrFXhKJWdjRAZfF4-hInjdxbox8UtTovsxdN9c9831MMYRuRmQOnR6Gw6xPQbUXee8FtWACUIq3W167e0f2n-tvwHeqG6M</recordid><startdate>20171001</startdate><enddate>20171001</enddate><creator>Rodriguez-Ramos, M</creator><creator>Garcia-Munoz, M</creator><creator>Jimenez-Ramos, M C</creator><creator>Lopez, J Garcia</creator><creator>Galdon-Quiroga, J</creator><creator>Sanchis-Sanchez, L</creator><creator>Ayllon-Guerola, J</creator><creator>Faitsch, M</creator><creator>Gonzalez-Martin, J</creator><creator>Hermann, A</creator><creator>Marne, P de</creator><creator>Rivero-Rodriguez, J F</creator><creator>Sieglin, B</creator><creator>Snicker, A</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8127-3921</orcidid></search><sort><creationdate>20171001</creationdate><title>First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak</title><author>Rodriguez-Ramos, M ; Garcia-Munoz, M ; Jimenez-Ramos, M C ; Lopez, J Garcia ; Galdon-Quiroga, J ; Sanchis-Sanchez, L ; Ayllon-Guerola, J ; Faitsch, M ; Gonzalez-Martin, J ; Hermann, A ; Marne, P de ; Rivero-Rodriguez, J F ; Sieglin, B ; Snicker, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-f5cef9469ce6f3b4ee0505244911db7585bacb30a329b86b56344c6c78ef11643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>absolute flux</topic><topic>fast-ion</topic><topic>fast-ion loss detector</topic><topic>ionoluminescence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rodriguez-Ramos, M</creatorcontrib><creatorcontrib>Garcia-Munoz, M</creatorcontrib><creatorcontrib>Jimenez-Ramos, M C</creatorcontrib><creatorcontrib>Lopez, J Garcia</creatorcontrib><creatorcontrib>Galdon-Quiroga, J</creatorcontrib><creatorcontrib>Sanchis-Sanchez, L</creatorcontrib><creatorcontrib>Ayllon-Guerola, J</creatorcontrib><creatorcontrib>Faitsch, M</creatorcontrib><creatorcontrib>Gonzalez-Martin, J</creatorcontrib><creatorcontrib>Hermann, A</creatorcontrib><creatorcontrib>Marne, P de</creatorcontrib><creatorcontrib>Rivero-Rodriguez, J F</creatorcontrib><creatorcontrib>Sieglin, B</creatorcontrib><creatorcontrib>Snicker, A</creatorcontrib><creatorcontrib>the ASDEX Upgrade Team</creatorcontrib><collection>CrossRef</collection><jtitle>Plasma physics and controlled fusion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rodriguez-Ramos, M</au><au>Garcia-Munoz, M</au><au>Jimenez-Ramos, M C</au><au>Lopez, J Garcia</au><au>Galdon-Quiroga, J</au><au>Sanchis-Sanchez, L</au><au>Ayllon-Guerola, J</au><au>Faitsch, M</au><au>Gonzalez-Martin, J</au><au>Hermann, A</au><au>Marne, P de</au><au>Rivero-Rodriguez, J F</au><au>Sieglin, B</au><au>Snicker, A</au><aucorp>the ASDEX Upgrade Team</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak</atitle><jtitle>Plasma physics and controlled fusion</jtitle><stitle>PPCF</stitle><addtitle>Plasma Phys. Control. Fusion</addtitle><date>2017-10-01</date><risdate>2017</risdate><volume>59</volume><issue>10</issue><spage>105009</spage><pages>105009-</pages><issn>0741-3335</issn><eissn>1361-6587</eissn><coden>PLPHBZ</coden><abstract>A new diagnostic technique that allows to obtain absolute fluxes of fast-ion losses measured with absolutely calibrated scintillator based fast-ion loss detectors (FILD) is presented here. First absolute fluxes of fast-ion losses have been obtained in the ASDEX Upgrade tokamak. An instrument function that includes the scintillator efficiency, collimator geometry, optical transmission and camera efficiency has been constructed. The scintillator response to deuterium ions in the relevant energy range of fast-ions has been characterized using a tandem accelerator. Absolute flux of neutral beam injection (NBI) prompt losses has been obtained in magnetohydrodynamic quiescent plasmas. The temporal evolution of the heat load measured with FILD follows that measured at the FILD entrance obtained with an Infra-Red camera looking at the FILD detector head. ASCOT simulations are in good agreement with the absolute heat load of NBI prompt losses measured with FILD.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6587/aa7e5f</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8127-3921</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0741-3335
ispartof Plasma physics and controlled fusion, 2017-10, Vol.59 (10), p.105009
issn 0741-3335
1361-6587
language eng
recordid cdi_iop_journals_10_1088_1361_6587_aa7e5f
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects absolute flux
fast-ion
fast-ion loss detector
ionoluminescence
title First absolute measurements of fast-ion losses in the ASDEX Upgrade tokamak
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T21%3A39%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=First%20absolute%20measurements%20of%20fast-ion%20losses%20in%20the%20ASDEX%20Upgrade%20tokamak&rft.jtitle=Plasma%20physics%20and%20controlled%20fusion&rft.au=Rodriguez-Ramos,%20M&rft.aucorp=the%20ASDEX%20Upgrade%20Team&rft.date=2017-10-01&rft.volume=59&rft.issue=10&rft.spage=105009&rft.pages=105009-&rft.issn=0741-3335&rft.eissn=1361-6587&rft.coden=PLPHBZ&rft_id=info:doi/10.1088/1361-6587/aa7e5f&rft_dat=%3Ciop_cross%3Eppcfaa7e5f%3C/iop_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true