Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography

Many studies have been carried out on ultrasound computed tomography (USCT) for its ability to offer quantitative measurements of tissue sound speed. Full waveform inversion (FWI) is a technique for reconstructing high-resolution sound speed images by iteratively minimizing the difference between th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2024-05, Vol.69 (10), p.105024
Hauptverfasser: Wu, Yun, Yan, Weicheng, Liu, Zhaohui, Zhang, Qiude, Zhou, Liang, Song, Junjie, Qiu, Wu, Ding, Mingyue, Yuchi, Ming
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 10
container_start_page 105024
container_title Physics in medicine & biology
container_volume 69
creator Wu, Yun
Yan, Weicheng
Liu, Zhaohui
Zhang, Qiude
Zhou, Liang
Song, Junjie
Qiu, Wu
Ding, Mingyue
Yuchi, Ming
description Many studies have been carried out on ultrasound computed tomography (USCT) for its ability to offer quantitative measurements of tissue sound speed. Full waveform inversion (FWI) is a technique for reconstructing high-resolution sound speed images by iteratively minimizing the difference between the observed ultrasound data and the synthetic data based on the waveform equation. However, FWI suffers from cycle-skipping, which usually causes FWI convergence at a local minimum. Cycle-skipping occurs when the phase difference between the observed data and the synthetic data exceeds half a cycle. The simplest way to avoid cycle-skipping is to use low-frequency information for reconstruction. Nevertheless, in imaging systems, the response bandwidth of the probe is limited, and reliable low-frequency information often exceeds the response band. Therefore, it is a challenge to perform FWI imaging and avoid cycle-skipping problems without low-frequency information. In this paper, we propose a frequency shift envelope-based global correlation norm (FSEGCN), where an artificial source wavelet with a lower frequency is adopted to calculate synthetic data. FSEGCN compared with FWI, envelope inversion (EI), global correlation norm (GCN), envelope-based global correlation norm (EGCN) through concentric circle phantom without low-frequency information. The experimental results demonstrated the capability of the proposed method to recover the sound speed close to the exact model in the absence of low-frequency information, whereas FWI, EI, GCN, and EGCN cannot. Experiments on phantoms of the human head and calf show that artificial source wavelets can reduce image artifacts and enhance reconstruction robustness, when original low-frequency information is absent.
doi_str_mv 10.1088/1361-6560/ad3c8f
format Article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6560_ad3c8f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3035540349</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-e1eb1d174f29a610a46b91be292d3dac8e8b839efe7bc13cbce87964b6cf2a8e3</originalsourceid><addsrcrecordid>eNp1kEtPxCAURonR6PjYuzIsXViF0jKwNMZXYuJG1wToZayhpULRzL-3zfjY6IqE-33n5h6Ejik5p0SIC8o4LXjNyYVumBVuCy1-vrbRghBGC0nreg_tp_RKCKWirHbRHhO1ZILyBfq4yd7jD_0OLsQOt_07xNSGHufU9ivsIrxl6O0ap5fWjRimuQ8DFEYnaPDKB6M9tiFG8Hqce_2MmVg4-zHqFHLfTPNuyOOUH0MXVlEPL-tDtOO0T3D09R6g55vrp6u74uHx9v7q8qGwrCzHAigY2tBl5UqpOSW64kZSA6UsG9ZoK0AYwSQ4WBpLmTUWxFLyynDrSi2AHaDTDXeIYbokjaprkwXvdQ8hJ8UIq-uKsEpOUbKJ2hhSiuDUENtOx7WiRM261exWzW7VRvdUOfmiZ9NB81P49vu7vg2Deg059tOxauiM4nKDrUlZqaGZWWd_RP9d_Qnr6ZtU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3035540349</pqid></control><display><type>article</type><title>Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Wu, Yun ; Yan, Weicheng ; Liu, Zhaohui ; Zhang, Qiude ; Zhou, Liang ; Song, Junjie ; Qiu, Wu ; Ding, Mingyue ; Yuchi, Ming</creator><creatorcontrib>Wu, Yun ; Yan, Weicheng ; Liu, Zhaohui ; Zhang, Qiude ; Zhou, Liang ; Song, Junjie ; Qiu, Wu ; Ding, Mingyue ; Yuchi, Ming</creatorcontrib><description>Many studies have been carried out on ultrasound computed tomography (USCT) for its ability to offer quantitative measurements of tissue sound speed. Full waveform inversion (FWI) is a technique for reconstructing high-resolution sound speed images by iteratively minimizing the difference between the observed ultrasound data and the synthetic data based on the waveform equation. However, FWI suffers from cycle-skipping, which usually causes FWI convergence at a local minimum. Cycle-skipping occurs when the phase difference between the observed data and the synthetic data exceeds half a cycle. The simplest way to avoid cycle-skipping is to use low-frequency information for reconstruction. Nevertheless, in imaging systems, the response bandwidth of the probe is limited, and reliable low-frequency information often exceeds the response band. Therefore, it is a challenge to perform FWI imaging and avoid cycle-skipping problems without low-frequency information. In this paper, we propose a frequency shift envelope-based global correlation norm (FSEGCN), where an artificial source wavelet with a lower frequency is adopted to calculate synthetic data. FSEGCN compared with FWI, envelope inversion (EI), global correlation norm (GCN), envelope-based global correlation norm (EGCN) through concentric circle phantom without low-frequency information. The experimental results demonstrated the capability of the proposed method to recover the sound speed close to the exact model in the absence of low-frequency information, whereas FWI, EI, GCN, and EGCN cannot. Experiments on phantoms of the human head and calf show that artificial source wavelets can reduce image artifacts and enhance reconstruction robustness, when original low-frequency information is absent.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ad3c8f</identifier><identifier>PMID: 38593816</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>envelope ; frequency shift ; global correlation norm ; ultrasound computed tomography</subject><ispartof>Physics in medicine &amp; biology, 2024-05, Vol.69 (10), p.105024</ispartof><rights>2024 Institute of Physics and Engineering in Medicine</rights><rights>2024 Institute of Physics and Engineering in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c322t-e1eb1d174f29a610a46b91be292d3dac8e8b839efe7bc13cbce87964b6cf2a8e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/ad3c8f/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27903,27904,53824,53871</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38593816$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wu, Yun</creatorcontrib><creatorcontrib>Yan, Weicheng</creatorcontrib><creatorcontrib>Liu, Zhaohui</creatorcontrib><creatorcontrib>Zhang, Qiude</creatorcontrib><creatorcontrib>Zhou, Liang</creatorcontrib><creatorcontrib>Song, Junjie</creatorcontrib><creatorcontrib>Qiu, Wu</creatorcontrib><creatorcontrib>Ding, Mingyue</creatorcontrib><creatorcontrib>Yuchi, Ming</creatorcontrib><title>Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Many studies have been carried out on ultrasound computed tomography (USCT) for its ability to offer quantitative measurements of tissue sound speed. Full waveform inversion (FWI) is a technique for reconstructing high-resolution sound speed images by iteratively minimizing the difference between the observed ultrasound data and the synthetic data based on the waveform equation. However, FWI suffers from cycle-skipping, which usually causes FWI convergence at a local minimum. Cycle-skipping occurs when the phase difference between the observed data and the synthetic data exceeds half a cycle. The simplest way to avoid cycle-skipping is to use low-frequency information for reconstruction. Nevertheless, in imaging systems, the response bandwidth of the probe is limited, and reliable low-frequency information often exceeds the response band. Therefore, it is a challenge to perform FWI imaging and avoid cycle-skipping problems without low-frequency information. In this paper, we propose a frequency shift envelope-based global correlation norm (FSEGCN), where an artificial source wavelet with a lower frequency is adopted to calculate synthetic data. FSEGCN compared with FWI, envelope inversion (EI), global correlation norm (GCN), envelope-based global correlation norm (EGCN) through concentric circle phantom without low-frequency information. The experimental results demonstrated the capability of the proposed method to recover the sound speed close to the exact model in the absence of low-frequency information, whereas FWI, EI, GCN, and EGCN cannot. Experiments on phantoms of the human head and calf show that artificial source wavelets can reduce image artifacts and enhance reconstruction robustness, when original low-frequency information is absent.</description><subject>envelope</subject><subject>frequency shift</subject><subject>global correlation norm</subject><subject>ultrasound computed tomography</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp1kEtPxCAURonR6PjYuzIsXViF0jKwNMZXYuJG1wToZayhpULRzL-3zfjY6IqE-33n5h6Ejik5p0SIC8o4LXjNyYVumBVuCy1-vrbRghBGC0nreg_tp_RKCKWirHbRHhO1ZILyBfq4yd7jD_0OLsQOt_07xNSGHufU9ivsIrxl6O0ap5fWjRimuQ8DFEYnaPDKB6M9tiFG8Hqce_2MmVg4-zHqFHLfTPNuyOOUH0MXVlEPL-tDtOO0T3D09R6g55vrp6u74uHx9v7q8qGwrCzHAigY2tBl5UqpOSW64kZSA6UsG9ZoK0AYwSQ4WBpLmTUWxFLyynDrSi2AHaDTDXeIYbokjaprkwXvdQ8hJ8UIq-uKsEpOUbKJ2hhSiuDUENtOx7WiRM261exWzW7VRvdUOfmiZ9NB81P49vu7vg2Deg059tOxauiM4nKDrUlZqaGZWWd_RP9d_Qnr6ZtU</recordid><startdate>20240521</startdate><enddate>20240521</enddate><creator>Wu, Yun</creator><creator>Yan, Weicheng</creator><creator>Liu, Zhaohui</creator><creator>Zhang, Qiude</creator><creator>Zhou, Liang</creator><creator>Song, Junjie</creator><creator>Qiu, Wu</creator><creator>Ding, Mingyue</creator><creator>Yuchi, Ming</creator><general>IOP Publishing</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20240521</creationdate><title>Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography</title><author>Wu, Yun ; Yan, Weicheng ; Liu, Zhaohui ; Zhang, Qiude ; Zhou, Liang ; Song, Junjie ; Qiu, Wu ; Ding, Mingyue ; Yuchi, Ming</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-e1eb1d174f29a610a46b91be292d3dac8e8b839efe7bc13cbce87964b6cf2a8e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>envelope</topic><topic>frequency shift</topic><topic>global correlation norm</topic><topic>ultrasound computed tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wu, Yun</creatorcontrib><creatorcontrib>Yan, Weicheng</creatorcontrib><creatorcontrib>Liu, Zhaohui</creatorcontrib><creatorcontrib>Zhang, Qiude</creatorcontrib><creatorcontrib>Zhou, Liang</creatorcontrib><creatorcontrib>Song, Junjie</creatorcontrib><creatorcontrib>Qiu, Wu</creatorcontrib><creatorcontrib>Ding, Mingyue</creatorcontrib><creatorcontrib>Yuchi, Ming</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wu, Yun</au><au>Yan, Weicheng</au><au>Liu, Zhaohui</au><au>Zhang, Qiude</au><au>Zhou, Liang</au><au>Song, Junjie</au><au>Qiu, Wu</au><au>Ding, Mingyue</au><au>Yuchi, Ming</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2024-05-21</date><risdate>2024</risdate><volume>69</volume><issue>10</issue><spage>105024</spage><pages>105024-</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Many studies have been carried out on ultrasound computed tomography (USCT) for its ability to offer quantitative measurements of tissue sound speed. Full waveform inversion (FWI) is a technique for reconstructing high-resolution sound speed images by iteratively minimizing the difference between the observed ultrasound data and the synthetic data based on the waveform equation. However, FWI suffers from cycle-skipping, which usually causes FWI convergence at a local minimum. Cycle-skipping occurs when the phase difference between the observed data and the synthetic data exceeds half a cycle. The simplest way to avoid cycle-skipping is to use low-frequency information for reconstruction. Nevertheless, in imaging systems, the response bandwidth of the probe is limited, and reliable low-frequency information often exceeds the response band. Therefore, it is a challenge to perform FWI imaging and avoid cycle-skipping problems without low-frequency information. In this paper, we propose a frequency shift envelope-based global correlation norm (FSEGCN), where an artificial source wavelet with a lower frequency is adopted to calculate synthetic data. FSEGCN compared with FWI, envelope inversion (EI), global correlation norm (GCN), envelope-based global correlation norm (EGCN) through concentric circle phantom without low-frequency information. The experimental results demonstrated the capability of the proposed method to recover the sound speed close to the exact model in the absence of low-frequency information, whereas FWI, EI, GCN, and EGCN cannot. Experiments on phantoms of the human head and calf show that artificial source wavelets can reduce image artifacts and enhance reconstruction robustness, when original low-frequency information is absent.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>38593816</pmid><doi>10.1088/1361-6560/ad3c8f</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2024-05, Vol.69 (10), p.105024
issn 0031-9155
1361-6560
language eng
recordid cdi_iop_journals_10_1088_1361_6560_ad3c8f
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects envelope
frequency shift
global correlation norm
ultrasound computed tomography
title Full waveform inversion using frequency shift envelope-based global correlation norm for ultrasound computed tomography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T03%3A43%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Full%20waveform%20inversion%20using%20frequency%20shift%20envelope-based%20global%20correlation%20norm%20for%20ultrasound%20computed%20tomography&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Wu,%20Yun&rft.date=2024-05-21&rft.volume=69&rft.issue=10&rft.spage=105024&rft.pages=105024-&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ad3c8f&rft_dat=%3Cproquest_iop_j%3E3035540349%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3035540349&rft_id=info:pmid/38593816&rfr_iscdi=true