Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams

Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2020-12, Vol.65 (24), p.245042-245042
Hauptverfasser: Czarnecki, Damian, Zink, Klemens, Pimpinella, Maria, Borbinha, Jorge, Teles, Pedro, Pinto, Massimo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 245042
container_issue 24
container_start_page 245042
container_title Physics in medicine & biology
container_volume 65
creator Czarnecki, Damian
Zink, Klemens
Pimpinella, Maria
Borbinha, Jorge
Teles, Pedro
Pinto, Massimo
description Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors kQ,Q0, necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new kQ,Q0 factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor pQ, necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor kQ,Q0 for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor pQ, the data did not obey a comparable simple relationship with the beam quality specifier. The variation of pQ for all ion chambers was in the range of 3%-4%. Compared to recently published data, our pQ data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.
doi_str_mv 10.1088/1361-6560/abc5c9
format Article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6560_abc5c9</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2456419115</sourcerecordid><originalsourceid>FETCH-LOGICAL-c477t-e11e791606c4c227e4e13c7b7ea3c8d465e9fd6e9c6d8b1f37f0ee8707e044cb3</originalsourceid><addsrcrecordid>eNp9kEFP3DAQRq2qVVlo7z0hHzmQ4okdOzmiFRQkql7aszV2JlVoEgc7UdkbP73eLuWEerL0-c2nmcfYJxCfQdT1BUgNha60uEDnK9-8YZuX6C3bCCGhaKCqjthxSvdCANSles-OpIRSSFNu2NPXMC3EtxiHwD0Ofh1w6cPEQ8cfVhz6Zcd9iJH837RDv4SYuMNELc8B9pH_ojgix6nl6FKILv-0IRFfAv-NC0XeT3yktl9HThPFnzv-WETccUc4pg_sXYdDoo_P7wn7cX31fXtT3H37cru9vCu8MmYpCIBMA1por3xZGlIE0htnCKWvW6UrarpWU-N1WzvopOkEUW2EIaGUd_KEnR165xgeVkqLHfvkaRhworAmW6pKK2gAqoyKA-pjSClSZ-fYjxh3FoTde7d7yXYv2R6855HT5_bV5VNfBv6JzsD5AejDbO_DGqd87P_6zl7B59FlKq-631ao0s5tJ_8ABfebkw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2456419115</pqid></control><display><type>article</type><title>Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Czarnecki, Damian ; Zink, Klemens ; Pimpinella, Maria ; Borbinha, Jorge ; Teles, Pedro ; Pinto, Massimo</creator><creatorcontrib>Czarnecki, Damian ; Zink, Klemens ; Pimpinella, Maria ; Borbinha, Jorge ; Teles, Pedro ; Pinto, Massimo</creatorcontrib><description>Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors kQ,Q0, necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new kQ,Q0 factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor pQ, necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor kQ,Q0 for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor pQ, the data did not obey a comparable simple relationship with the beam quality specifier. The variation of pQ for all ion chambers was in the range of 3%-4%. Compared to recently published data, our pQ data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/abc5c9</identifier><identifier>PMID: 33120372</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Calibration ; dosimetry ; Humans ; IAEA TRS-398 ; medium energy x-rays ; Monte Carlo Method ; Monte Carlo simulations ; Photons ; Radiometry - methods ; Relative Biological Effectiveness ; Water ; X-Rays</subject><ispartof>Physics in medicine &amp; biology, 2020-12, Vol.65 (24), p.245042-245042</ispartof><rights>2020 Institute of Physics and Engineering in Medicine</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c477t-e11e791606c4c227e4e13c7b7ea3c8d465e9fd6e9c6d8b1f37f0ee8707e044cb3</citedby><cites>FETCH-LOGICAL-c477t-e11e791606c4c227e4e13c7b7ea3c8d465e9fd6e9c6d8b1f37f0ee8707e044cb3</cites><orcidid>0000-0001-5785-4101 ; 0000-0002-8122-7084</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/abc5c9/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,778,782,27907,27908,53829,53876</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33120372$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Czarnecki, Damian</creatorcontrib><creatorcontrib>Zink, Klemens</creatorcontrib><creatorcontrib>Pimpinella, Maria</creatorcontrib><creatorcontrib>Borbinha, Jorge</creatorcontrib><creatorcontrib>Teles, Pedro</creatorcontrib><creatorcontrib>Pinto, Massimo</creatorcontrib><title>Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors kQ,Q0, necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new kQ,Q0 factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor pQ, necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor kQ,Q0 for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor pQ, the data did not obey a comparable simple relationship with the beam quality specifier. The variation of pQ for all ion chambers was in the range of 3%-4%. Compared to recently published data, our pQ data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.</description><subject>Calibration</subject><subject>dosimetry</subject><subject>Humans</subject><subject>IAEA TRS-398</subject><subject>medium energy x-rays</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo simulations</subject><subject>Photons</subject><subject>Radiometry - methods</subject><subject>Relative Biological Effectiveness</subject><subject>Water</subject><subject>X-Rays</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>EIF</sourceid><recordid>eNp9kEFP3DAQRq2qVVlo7z0hHzmQ4okdOzmiFRQkql7aszV2JlVoEgc7UdkbP73eLuWEerL0-c2nmcfYJxCfQdT1BUgNha60uEDnK9-8YZuX6C3bCCGhaKCqjthxSvdCANSles-OpIRSSFNu2NPXMC3EtxiHwD0Ofh1w6cPEQ8cfVhz6Zcd9iJH837RDv4SYuMNELc8B9pH_ojgix6nl6FKILv-0IRFfAv-NC0XeT3yktl9HThPFnzv-WETccUc4pg_sXYdDoo_P7wn7cX31fXtT3H37cru9vCu8MmYpCIBMA1por3xZGlIE0htnCKWvW6UrarpWU-N1WzvopOkEUW2EIaGUd_KEnR165xgeVkqLHfvkaRhworAmW6pKK2gAqoyKA-pjSClSZ-fYjxh3FoTde7d7yXYv2R6855HT5_bV5VNfBv6JzsD5AejDbO_DGqd87P_6zl7B59FlKq-631ao0s5tJ_8ABfebkw</recordid><startdate>20201221</startdate><enddate>20201221</enddate><creator>Czarnecki, Damian</creator><creator>Zink, Klemens</creator><creator>Pimpinella, Maria</creator><creator>Borbinha, Jorge</creator><creator>Teles, Pedro</creator><creator>Pinto, Massimo</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5785-4101</orcidid><orcidid>https://orcid.org/0000-0002-8122-7084</orcidid></search><sort><creationdate>20201221</creationdate><title>Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams</title><author>Czarnecki, Damian ; Zink, Klemens ; Pimpinella, Maria ; Borbinha, Jorge ; Teles, Pedro ; Pinto, Massimo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c477t-e11e791606c4c227e4e13c7b7ea3c8d465e9fd6e9c6d8b1f37f0ee8707e044cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Calibration</topic><topic>dosimetry</topic><topic>Humans</topic><topic>IAEA TRS-398</topic><topic>medium energy x-rays</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo simulations</topic><topic>Photons</topic><topic>Radiometry - methods</topic><topic>Relative Biological Effectiveness</topic><topic>Water</topic><topic>X-Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Czarnecki, Damian</creatorcontrib><creatorcontrib>Zink, Klemens</creatorcontrib><creatorcontrib>Pimpinella, Maria</creatorcontrib><creatorcontrib>Borbinha, Jorge</creatorcontrib><creatorcontrib>Teles, Pedro</creatorcontrib><creatorcontrib>Pinto, Massimo</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Czarnecki, Damian</au><au>Zink, Klemens</au><au>Pimpinella, Maria</au><au>Borbinha, Jorge</au><au>Teles, Pedro</au><au>Pinto, Massimo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2020-12-21</date><risdate>2020</risdate><volume>65</volume><issue>24</issue><spage>245042</spage><epage>245042</epage><pages>245042-245042</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors kQ,Q0, necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new kQ,Q0 factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor pQ, necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor kQ,Q0 for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor pQ, the data did not obey a comparable simple relationship with the beam quality specifier. The variation of pQ for all ion chambers was in the range of 3%-4%. Compared to recently published data, our pQ data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>33120372</pmid><doi>10.1088/1361-6560/abc5c9</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0001-5785-4101</orcidid><orcidid>https://orcid.org/0000-0002-8122-7084</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2020-12, Vol.65 (24), p.245042-245042
issn 0031-9155
1361-6560
language eng
recordid cdi_iop_journals_10_1088_1361_6560_abc5c9
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Calibration
dosimetry
Humans
IAEA TRS-398
medium energy x-rays
Monte Carlo Method
Monte Carlo simulations
Photons
Radiometry - methods
Relative Biological Effectiveness
Water
X-Rays
title Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T17%3A13%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20calculation%20of%20quality%20correction%20factors%20based%20on%20air%20kerma%20and%20absorbed%20dose%20to%20water%20in%20medium%20energy%20x-ray%20beams&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Czarnecki,%20Damian&rft.date=2020-12-21&rft.volume=65&rft.issue=24&rft.spage=245042&rft.epage=245042&rft.pages=245042-245042&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/abc5c9&rft_dat=%3Cproquest_iop_j%3E2456419115%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2456419115&rft_id=info:pmid/33120372&rfr_iscdi=true