Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy
Carbon ion radiotherapy is an attractive alternative to conventional radiotherapy, especially in case of deep-seated and radio-resistant tumors. As a consequence of inelastic nuclear reactions between primary particles and patient's tissues, the primary carbon ions may undergo nuclear fragmenta...
Gespeichert in:
Veröffentlicht in: | Physics in medicine & biology 2019-03, Vol.64 (5), p.055018-055018 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 055018 |
---|---|
container_issue | 5 |
container_start_page | 055018 |
container_title | Physics in medicine & biology |
container_volume | 64 |
creator | Aricò, G Gehrke, T Gallas, R Mairani, A Jäkel, O Martišíková, M |
description | Carbon ion radiotherapy is an attractive alternative to conventional radiotherapy, especially in case of deep-seated and radio-resistant tumors. As a consequence of inelastic nuclear reactions between primary particles and patient's tissues, the primary carbon ions may undergo nuclear fragmentation. The resulting decrease of primary ions and production of secondary fragments have to be carefully considered for accurate dose calculations in the treatment planning systems. The experimental data currently available provide only general information on carbon ion fragmentation and are not sufficient to cover the entire range of beam energies, target configurations and compositions relevant for radiotherapy. Therefore, new investigations were carried out to analyse the outcomes of the inelastic nuclear reaction processes on a single-ion-based approach. Measurements were performed at HIT, using 430 MeV/u carbon ion beams crossing water and PMMA targets. Unique in this method is the possibility of measuring number and type of fragments produced from each single carbon ion, provided that they are within the acceptance of the experimental apparatus. Concerning the amount of residual carbon ions behind water and PMMA targets with the same water equivalent thickness (WET), no significant differences were found. The experimental attenuation curve was well reproduced by the simulations. However, in the experiments, differences were observed regarding the amount of secondary fragments produced in water and in PMMA targets with the same WET. Differences were also found between experiments and simulations. These findings should be considered when dosimetric measurements are performed with PMMA instead of water phantoms. The found differences between experiments and simulations may contribute to improve the nuclear interaction and fragmentation models in Monte Carlo codes. |
doi_str_mv | 10.1088/1361-6560/aafa46 |
format | Article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6560_aafa46</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2159989133</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-db3f21a90d954425809ec103b1c3b64b54de30785ebb91066a1d26f391009a613</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhi0EoqWwM6FsMBB6F8duPFYVH5WoYKCzZSd2m6r5wE5B_fckSumEmGy999wr3UPINcIDQpKMkXIMOeMwVsqqmJ-Q4TE6JUMAiqFAxgbkwvsNAGISxedkQIFNIopiSJbz8sv4Jl-pJq_KoLKBz8vV1gSpcroNutA6tSpM2fRIXgbfqjEuUGUWvC8W08BWLlirzLXDZm2cqveX5MyqrTdXh3dElk-PH7OX8PXteT6bvoZpDJMmzDS1ESoBmWBxHLEEhEkRqMaUah5rFmeGwiRhRmuBwLnCLOKWtn8QiiMdkbu-t3bV5669Qxa5T812q0pT7byMkAmRCKS0RaFHU1d574yVtcsL5fYSQXYyZWdOduZkL7NduTm073RhsuPCr70WuO-BvKrlptq5sj32v77bP_C60JLHkklgDDCRdWbpD13bikA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2159989133</pqid></control><display><type>article</type><title>Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Aricò, G ; Gehrke, T ; Gallas, R ; Mairani, A ; Jäkel, O ; Martišíková, M</creator><creatorcontrib>Aricò, G ; Gehrke, T ; Gallas, R ; Mairani, A ; Jäkel, O ; Martišíková, M</creatorcontrib><description>Carbon ion radiotherapy is an attractive alternative to conventional radiotherapy, especially in case of deep-seated and radio-resistant tumors. As a consequence of inelastic nuclear reactions between primary particles and patient's tissues, the primary carbon ions may undergo nuclear fragmentation. The resulting decrease of primary ions and production of secondary fragments have to be carefully considered for accurate dose calculations in the treatment planning systems. The experimental data currently available provide only general information on carbon ion fragmentation and are not sufficient to cover the entire range of beam energies, target configurations and compositions relevant for radiotherapy. Therefore, new investigations were carried out to analyse the outcomes of the inelastic nuclear reaction processes on a single-ion-based approach. Measurements were performed at HIT, using 430 MeV/u carbon ion beams crossing water and PMMA targets. Unique in this method is the possibility of measuring number and type of fragments produced from each single carbon ion, provided that they are within the acceptance of the experimental apparatus. Concerning the amount of residual carbon ions behind water and PMMA targets with the same water equivalent thickness (WET), no significant differences were found. The experimental attenuation curve was well reproduced by the simulations. However, in the experiments, differences were observed regarding the amount of secondary fragments produced in water and in PMMA targets with the same WET. Differences were also found between experiments and simulations. These findings should be considered when dosimetric measurements are performed with PMMA instead of water phantoms. The found differences between experiments and simulations may contribute to improve the nuclear interaction and fragmentation models in Monte Carlo codes.</description><identifier>ISSN: 0031-9155</identifier><identifier>ISSN: 1361-6560</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/aafa46</identifier><identifier>PMID: 30572319</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Carbon - chemistry ; Carbon - therapeutic use ; FLUKA simulations ; Heavy Ion Radiotherapy - methods ; Humans ; ion beam radiotherapy ; Monte Carlo Method ; nuclear interactions and fragmentation ; Phantoms, Imaging ; Polymethyl Methacrylate - chemistry ; Radiometry ; Radiotherapy Planning, Computer-Assisted ; Timepix detectors ; Water - chemistry</subject><ispartof>Physics in medicine & biology, 2019-03, Vol.64 (5), p.055018-055018</ispartof><rights>2019 Institute of Physics and Engineering in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-db3f21a90d954425809ec103b1c3b64b54de30785ebb91066a1d26f391009a613</citedby><cites>FETCH-LOGICAL-c407t-db3f21a90d954425809ec103b1c3b64b54de30785ebb91066a1d26f391009a613</cites><orcidid>0000-0002-6056-9747</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/aafa46/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30572319$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Aricò, G</creatorcontrib><creatorcontrib>Gehrke, T</creatorcontrib><creatorcontrib>Gallas, R</creatorcontrib><creatorcontrib>Mairani, A</creatorcontrib><creatorcontrib>Jäkel, O</creatorcontrib><creatorcontrib>Martišíková, M</creatorcontrib><title>Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy</title><title>Physics in medicine & biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Carbon ion radiotherapy is an attractive alternative to conventional radiotherapy, especially in case of deep-seated and radio-resistant tumors. As a consequence of inelastic nuclear reactions between primary particles and patient's tissues, the primary carbon ions may undergo nuclear fragmentation. The resulting decrease of primary ions and production of secondary fragments have to be carefully considered for accurate dose calculations in the treatment planning systems. The experimental data currently available provide only general information on carbon ion fragmentation and are not sufficient to cover the entire range of beam energies, target configurations and compositions relevant for radiotherapy. Therefore, new investigations were carried out to analyse the outcomes of the inelastic nuclear reaction processes on a single-ion-based approach. Measurements were performed at HIT, using 430 MeV/u carbon ion beams crossing water and PMMA targets. Unique in this method is the possibility of measuring number and type of fragments produced from each single carbon ion, provided that they are within the acceptance of the experimental apparatus. Concerning the amount of residual carbon ions behind water and PMMA targets with the same water equivalent thickness (WET), no significant differences were found. The experimental attenuation curve was well reproduced by the simulations. However, in the experiments, differences were observed regarding the amount of secondary fragments produced in water and in PMMA targets with the same WET. Differences were also found between experiments and simulations. These findings should be considered when dosimetric measurements are performed with PMMA instead of water phantoms. The found differences between experiments and simulations may contribute to improve the nuclear interaction and fragmentation models in Monte Carlo codes.</description><subject>Carbon - chemistry</subject><subject>Carbon - therapeutic use</subject><subject>FLUKA simulations</subject><subject>Heavy Ion Radiotherapy - methods</subject><subject>Humans</subject><subject>ion beam radiotherapy</subject><subject>Monte Carlo Method</subject><subject>nuclear interactions and fragmentation</subject><subject>Phantoms, Imaging</subject><subject>Polymethyl Methacrylate - chemistry</subject><subject>Radiometry</subject><subject>Radiotherapy Planning, Computer-Assisted</subject><subject>Timepix detectors</subject><subject>Water - chemistry</subject><issn>0031-9155</issn><issn>1361-6560</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kD1PwzAQhi0EoqWwM6FsMBB6F8duPFYVH5WoYKCzZSd2m6r5wE5B_fckSumEmGy999wr3UPINcIDQpKMkXIMOeMwVsqqmJ-Q4TE6JUMAiqFAxgbkwvsNAGISxedkQIFNIopiSJbz8sv4Jl-pJq_KoLKBz8vV1gSpcroNutA6tSpM2fRIXgbfqjEuUGUWvC8W08BWLlirzLXDZm2cqveX5MyqrTdXh3dElk-PH7OX8PXteT6bvoZpDJMmzDS1ESoBmWBxHLEEhEkRqMaUah5rFmeGwiRhRmuBwLnCLOKWtn8QiiMdkbu-t3bV5669Qxa5T812q0pT7byMkAmRCKS0RaFHU1d574yVtcsL5fYSQXYyZWdOduZkL7NduTm073RhsuPCr70WuO-BvKrlptq5sj32v77bP_C60JLHkklgDDCRdWbpD13bikA</recordid><startdate>20190307</startdate><enddate>20190307</enddate><creator>Aricò, G</creator><creator>Gehrke, T</creator><creator>Gallas, R</creator><creator>Mairani, A</creator><creator>Jäkel, O</creator><creator>Martišíková, M</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-6056-9747</orcidid></search><sort><creationdate>20190307</creationdate><title>Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy</title><author>Aricò, G ; Gehrke, T ; Gallas, R ; Mairani, A ; Jäkel, O ; Martišíková, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-db3f21a90d954425809ec103b1c3b64b54de30785ebb91066a1d26f391009a613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Carbon - chemistry</topic><topic>Carbon - therapeutic use</topic><topic>FLUKA simulations</topic><topic>Heavy Ion Radiotherapy - methods</topic><topic>Humans</topic><topic>ion beam radiotherapy</topic><topic>Monte Carlo Method</topic><topic>nuclear interactions and fragmentation</topic><topic>Phantoms, Imaging</topic><topic>Polymethyl Methacrylate - chemistry</topic><topic>Radiometry</topic><topic>Radiotherapy Planning, Computer-Assisted</topic><topic>Timepix detectors</topic><topic>Water - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aricò, G</creatorcontrib><creatorcontrib>Gehrke, T</creatorcontrib><creatorcontrib>Gallas, R</creatorcontrib><creatorcontrib>Mairani, A</creatorcontrib><creatorcontrib>Jäkel, O</creatorcontrib><creatorcontrib>Martišíková, M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine & biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aricò, G</au><au>Gehrke, T</au><au>Gallas, R</au><au>Mairani, A</au><au>Jäkel, O</au><au>Martišíková, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy</atitle><jtitle>Physics in medicine & biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2019-03-07</date><risdate>2019</risdate><volume>64</volume><issue>5</issue><spage>055018</spage><epage>055018</epage><pages>055018-055018</pages><issn>0031-9155</issn><issn>1361-6560</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Carbon ion radiotherapy is an attractive alternative to conventional radiotherapy, especially in case of deep-seated and radio-resistant tumors. As a consequence of inelastic nuclear reactions between primary particles and patient's tissues, the primary carbon ions may undergo nuclear fragmentation. The resulting decrease of primary ions and production of secondary fragments have to be carefully considered for accurate dose calculations in the treatment planning systems. The experimental data currently available provide only general information on carbon ion fragmentation and are not sufficient to cover the entire range of beam energies, target configurations and compositions relevant for radiotherapy. Therefore, new investigations were carried out to analyse the outcomes of the inelastic nuclear reaction processes on a single-ion-based approach. Measurements were performed at HIT, using 430 MeV/u carbon ion beams crossing water and PMMA targets. Unique in this method is the possibility of measuring number and type of fragments produced from each single carbon ion, provided that they are within the acceptance of the experimental apparatus. Concerning the amount of residual carbon ions behind water and PMMA targets with the same water equivalent thickness (WET), no significant differences were found. The experimental attenuation curve was well reproduced by the simulations. However, in the experiments, differences were observed regarding the amount of secondary fragments produced in water and in PMMA targets with the same WET. Differences were also found between experiments and simulations. These findings should be considered when dosimetric measurements are performed with PMMA instead of water phantoms. The found differences between experiments and simulations may contribute to improve the nuclear interaction and fragmentation models in Monte Carlo codes.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>30572319</pmid><doi>10.1088/1361-6560/aafa46</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0002-6056-9747</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-9155 |
ispartof | Physics in medicine & biology, 2019-03, Vol.64 (5), p.055018-055018 |
issn | 0031-9155 1361-6560 1361-6560 |
language | eng |
recordid | cdi_iop_journals_10_1088_1361_6560_aafa46 |
source | MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
subjects | Carbon - chemistry Carbon - therapeutic use FLUKA simulations Heavy Ion Radiotherapy - methods Humans ion beam radiotherapy Monte Carlo Method nuclear interactions and fragmentation Phantoms, Imaging Polymethyl Methacrylate - chemistry Radiometry Radiotherapy Planning, Computer-Assisted Timepix detectors Water - chemistry |
title | Investigation of single carbon ion fragmentation in water and PMMA for hadron therapy |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T05%3A11%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Investigation%20of%20single%20carbon%20ion%20fragmentation%20in%20water%20and%20PMMA%20for%20hadron%20therapy&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Aric%C3%B2,%20G&rft.date=2019-03-07&rft.volume=64&rft.issue=5&rft.spage=055018&rft.epage=055018&rft.pages=055018-055018&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/aafa46&rft_dat=%3Cproquest_iop_j%3E2159989133%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2159989133&rft_id=info:pmid/30572319&rfr_iscdi=true |