Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping

The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Quantum electronics (Woodbury, N.Y.) N.Y.), 2018-04, Vol.48 (4), p.335-339
Hauptverfasser: Frolov, S.A., Trunov, V.I., Bagayev, S.N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 339
container_issue 4
container_start_page 335
container_title Quantum electronics (Woodbury, N.Y.)
container_volume 48
creator Frolov, S.A.
Trunov, V.I.
Bagayev, S.N.
description The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of the parameters of amplified radiation to angular instability of the pump beams sharply increases. With increasing number of the pump beams, the sensitivity of the parameters to fluctuations of the pump beam propagation angle weakly varies. It is found that if a substantial number (n ≫ 1) of 2-cm-diameter beams amplified in parametric amplifiers under multiple-beam pumping are coherently combined, then obtaining the 98 % efficiency of this process requires the angular stabilisation of the pump beams better than 50 μrad. Fluctuations of other pump beam parameters such as energy, phase aberrations, and relative jitter either affect only the amplitude of the pulse amplified or the influence on the phase profile of the amplified beam is at most 10−2 rad, which should not noticeably affect the coherent combining of amplified pulses.
doi_str_mv 10.1070/QEL16645
format Article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_1070_QEL16645</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2357617871</sourcerecordid><originalsourceid>FETCH-LOGICAL-c312t-7e1b97f9348bfbcaf24bfc1e3a58577b7c851a915ea3575c0596d1f772651e4d3</originalsourceid><addsrcrecordid>eNpl0E1LxDAQgOEgCi664E8I6MFLNWmTJj3Ksn7Aggh6Lkk6cSNtUpMW8d8bWXUPnmYODy_DIHRGyRUlglw_rTe0rhk_QAvKalkw0TSHeSd1VQhJ5TFapuQ04YwRLmu5QN0qbCGCn7AJg3be-VccLB7nPkHCahh7Zx102Hn84TrQynd4VFENMEVn_kBMePYdRDzM_eTGHgoNasiZYczFU3RkVQ4uf-YJerldP6_ui83j3cPqZlOYipZTIYDqRtimYlJbbZQtmbaGQqW45EJoYSSnqqEcVMUFN4Q3dUetEGXNKbCuOkHnu25Ik2uTcROYrQneg5nasiKElIzv1RjD-wxpat_CHH0-LBsuaiqkoFld7pSJIaUIth2jG1T8bClpv5_d_j4704sddWHct_6xL6xIfOY</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2357617871</pqid></control><display><type>article</type><title>Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Frolov, S.A. ; Trunov, V.I. ; Bagayev, S.N.</creator><creatorcontrib>Frolov, S.A. ; Trunov, V.I. ; Bagayev, S.N.</creatorcontrib><description>The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of the parameters of amplified radiation to angular instability of the pump beams sharply increases. With increasing number of the pump beams, the sensitivity of the parameters to fluctuations of the pump beam propagation angle weakly varies. It is found that if a substantial number (n ≫ 1) of 2-cm-diameter beams amplified in parametric amplifiers under multiple-beam pumping are coherently combined, then obtaining the 98 % efficiency of this process requires the angular stabilisation of the pump beams better than 50 μrad. Fluctuations of other pump beam parameters such as energy, phase aberrations, and relative jitter either affect only the amplitude of the pulse amplified or the influence on the phase profile of the amplified beam is at most 10−2 rad, which should not noticeably affect the coherent combining of amplified pulses.</description><identifier>ISSN: 1063-7818</identifier><identifier>EISSN: 1468-4799</identifier><identifier>DOI: 10.1070/QEL16645</identifier><language>eng</language><publisher>Bristol: Kvantovaya Elektronika, Turpion Ltd and IOP Publishing</publisher><subject>AMPLITUDES ; BEAMS ; Beams (radiation) ; Broadband ; CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS ; Coherence ; coherent combining ; CRYSTALS ; Femtosecond pulses ; FLUCTUATIONS ; INSTABILITY ; LBO ; multiple-beam pumping ; Parameter sensitivity ; parametric amplification ; PARAMETRIC AMPLIFIERS ; PULSES ; PUMPING ; SENSITIVITY ; Variation ; Vibration</subject><ispartof>Quantum electronics (Woodbury, N.Y.), 2018-04, Vol.48 (4), p.335-339</ispartof><rights>2018 Kvantovaya Elektronika, Turpion Ltd and IOP Publishing Ltd</rights><rights>Copyright IOP Publishing Apr 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c312t-7e1b97f9348bfbcaf24bfc1e3a58577b7c851a915ea3575c0596d1f772651e4d3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1070/QEL16645/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>230,314,776,780,881,27901,27902,53821,53868</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/23000245$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Frolov, S.A.</creatorcontrib><creatorcontrib>Trunov, V.I.</creatorcontrib><creatorcontrib>Bagayev, S.N.</creatorcontrib><title>Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping</title><title>Quantum electronics (Woodbury, N.Y.)</title><addtitle>Quantum Electron</addtitle><description>The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of the parameters of amplified radiation to angular instability of the pump beams sharply increases. With increasing number of the pump beams, the sensitivity of the parameters to fluctuations of the pump beam propagation angle weakly varies. It is found that if a substantial number (n ≫ 1) of 2-cm-diameter beams amplified in parametric amplifiers under multiple-beam pumping are coherently combined, then obtaining the 98 % efficiency of this process requires the angular stabilisation of the pump beams better than 50 μrad. Fluctuations of other pump beam parameters such as energy, phase aberrations, and relative jitter either affect only the amplitude of the pulse amplified or the influence on the phase profile of the amplified beam is at most 10−2 rad, which should not noticeably affect the coherent combining of amplified pulses.</description><subject>AMPLITUDES</subject><subject>BEAMS</subject><subject>Beams (radiation)</subject><subject>Broadband</subject><subject>CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS</subject><subject>Coherence</subject><subject>coherent combining</subject><subject>CRYSTALS</subject><subject>Femtosecond pulses</subject><subject>FLUCTUATIONS</subject><subject>INSTABILITY</subject><subject>LBO</subject><subject>multiple-beam pumping</subject><subject>Parameter sensitivity</subject><subject>parametric amplification</subject><subject>PARAMETRIC AMPLIFIERS</subject><subject>PULSES</subject><subject>PUMPING</subject><subject>SENSITIVITY</subject><subject>Variation</subject><subject>Vibration</subject><issn>1063-7818</issn><issn>1468-4799</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpl0E1LxDAQgOEgCi664E8I6MFLNWmTJj3Ksn7Aggh6Lkk6cSNtUpMW8d8bWXUPnmYODy_DIHRGyRUlglw_rTe0rhk_QAvKalkw0TSHeSd1VQhJ5TFapuQ04YwRLmu5QN0qbCGCn7AJg3be-VccLB7nPkHCahh7Zx102Hn84TrQynd4VFENMEVn_kBMePYdRDzM_eTGHgoNasiZYczFU3RkVQ4uf-YJerldP6_ui83j3cPqZlOYipZTIYDqRtimYlJbbZQtmbaGQqW45EJoYSSnqqEcVMUFN4Q3dUetEGXNKbCuOkHnu25Ik2uTcROYrQneg5nasiKElIzv1RjD-wxpat_CHH0-LBsuaiqkoFld7pSJIaUIth2jG1T8bClpv5_d_j4704sddWHct_6xL6xIfOY</recordid><startdate>20180401</startdate><enddate>20180401</enddate><creator>Frolov, S.A.</creator><creator>Trunov, V.I.</creator><creator>Bagayev, S.N.</creator><general>Kvantovaya Elektronika, Turpion Ltd and IOP Publishing</general><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20180401</creationdate><title>Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping</title><author>Frolov, S.A. ; Trunov, V.I. ; Bagayev, S.N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c312t-7e1b97f9348bfbcaf24bfc1e3a58577b7c851a915ea3575c0596d1f772651e4d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>AMPLITUDES</topic><topic>BEAMS</topic><topic>Beams (radiation)</topic><topic>Broadband</topic><topic>CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS</topic><topic>Coherence</topic><topic>coherent combining</topic><topic>CRYSTALS</topic><topic>Femtosecond pulses</topic><topic>FLUCTUATIONS</topic><topic>INSTABILITY</topic><topic>LBO</topic><topic>multiple-beam pumping</topic><topic>Parameter sensitivity</topic><topic>parametric amplification</topic><topic>PARAMETRIC AMPLIFIERS</topic><topic>PULSES</topic><topic>PUMPING</topic><topic>SENSITIVITY</topic><topic>Variation</topic><topic>Vibration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Frolov, S.A.</creatorcontrib><creatorcontrib>Trunov, V.I.</creatorcontrib><creatorcontrib>Bagayev, S.N.</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>Quantum electronics (Woodbury, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Frolov, S.A.</au><au>Trunov, V.I.</au><au>Bagayev, S.N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping</atitle><jtitle>Quantum electronics (Woodbury, N.Y.)</jtitle><addtitle>Quantum Electron</addtitle><date>2018-04-01</date><risdate>2018</risdate><volume>48</volume><issue>4</issue><spage>335</spage><epage>339</epage><pages>335-339</pages><issn>1063-7818</issn><eissn>1468-4799</eissn><abstract>The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of the parameters of amplified radiation to angular instability of the pump beams sharply increases. With increasing number of the pump beams, the sensitivity of the parameters to fluctuations of the pump beam propagation angle weakly varies. It is found that if a substantial number (n ≫ 1) of 2-cm-diameter beams amplified in parametric amplifiers under multiple-beam pumping are coherently combined, then obtaining the 98 % efficiency of this process requires the angular stabilisation of the pump beams better than 50 μrad. Fluctuations of other pump beam parameters such as energy, phase aberrations, and relative jitter either affect only the amplitude of the pulse amplified or the influence on the phase profile of the amplified beam is at most 10−2 rad, which should not noticeably affect the coherent combining of amplified pulses.</abstract><cop>Bristol</cop><pub>Kvantovaya Elektronika, Turpion Ltd and IOP Publishing</pub><doi>10.1070/QEL16645</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1063-7818
ispartof Quantum electronics (Woodbury, N.Y.), 2018-04, Vol.48 (4), p.335-339
issn 1063-7818
1468-4799
language eng
recordid cdi_iop_journals_10_1070_QEL16645
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects AMPLITUDES
BEAMS
Beams (radiation)
Broadband
CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS
Coherence
coherent combining
CRYSTALS
Femtosecond pulses
FLUCTUATIONS
INSTABILITY
LBO
multiple-beam pumping
Parameter sensitivity
parametric amplification
PARAMETRIC AMPLIFIERS
PULSES
PUMPING
SENSITIVITY
Variation
Vibration
title Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T00%3A47%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coherent%20combining%20of%20pulses%20amplified%20in%20wideband%20parametric%20amplifiers%20under%20multiple-beam%20pumping&rft.jtitle=Quantum%20electronics%20(Woodbury,%20N.Y.)&rft.au=Frolov,%20S.A.&rft.date=2018-04-01&rft.volume=48&rft.issue=4&rft.spage=335&rft.epage=339&rft.pages=335-339&rft.issn=1063-7818&rft.eissn=1468-4799&rft_id=info:doi/10.1070/QEL16645&rft_dat=%3Cproquest_iop_j%3E2357617871%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2357617871&rft_id=info:pmid/&rfr_iscdi=true