Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits

In 31 rabbits the femoral head was replaced by a ceramic endoprosthesis. For 11 of the experimental animals the endoprostheses were made by the Arabia China Factory in Helsinki, and for 20 by Staatliche Porzellan Manufaktur in Berlin. The operation was performed under fully sterile conditions and th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta orthopaedica 1981, Vol.52 (2), p.207-213
Hauptverfasser: Riska, Erik B., Holmström, Teddy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 213
container_issue 2
container_start_page 207
container_title Acta orthopaedica
container_volume 52
creator Riska, Erik B.
Holmström, Teddy
description In 31 rabbits the femoral head was replaced by a ceramic endoprosthesis. For 11 of the experimental animals the endoprostheses were made by the Arabia China Factory in Helsinki, and for 20 by Staatliche Porzellan Manufaktur in Berlin. The operation was performed under fully sterile conditions and the follow-up time was between 6 and 34 weeks. The hip joint was examined clinically, roentgenologically, macroscopically and histologically. The bending tolerance of the ceramic endoprosthesis was not adequate. Mechanical loosening of the proximal part of the prosthesis occurred in 68 per cent and was combined with fracture of the prosthetic stem. This created a pseudarthrosis-like reaction in the acetabular area and limited the movement of the hip joint. The distal fragment of the stem was always surrounded by a thin layer of dense bone. In the nonfractured cases (32 per cent), however, the reaction was only moderate and the movement of the hip joint was well preserved. The tissue reactions to the ceramic material were slight, but the great number of secondary reactions following stem fractures make the use of the ceramic endoprosthesis questionable in experiments with rabbits.
doi_str_mv 10.3109/17453678108991783
format Article
fullrecord <record><control><sourceid>pubmed_infor</sourceid><recordid>TN_cdi_informahealthcare_journals_10_3109_17453678108991783</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>7246100</sourcerecordid><originalsourceid>FETCH-LOGICAL-c444t-c9e02640274f7456f11cb6577283f4dd8809560e910ab36fd8a37c835e4733143</originalsourceid><addsrcrecordid>eNp9kF9LwzAUxYMoc04_gA9CvkA1adImVV_G2JwwEKY--VDS_GEdbVOSDu23N2VjIKJP93LP_R0OB4BrjG4JRtkdZjQhKeMY8SzDjJMTMB5uEUl5fHrcGT0HF95vESKcZmgERiymKUZoDD7Wuq2E1LVuOmgN7DYaLnRtnajgUgsFix7OtBN1KeG8UbZ11ocfX_p7OG3g_KvVrhzg8P_a7VQPbQPXoijKzl-CMyMqr68OcwLeF_O32TJavTw9z6arSFJKu0hmGsUpRTGjJuRNDcaySBPGYk4MVYpzlCUp0hlGoiCpUVwQJjlJNGWEYEomAO99ZQjnnTZ5GzIJ1-cY5UNP-a-eAnOzZ9pdUWt1JA7FBP1xr5eNsa4Wn9ZVKu9EX1lnnGhk6Qfrv-0ffuAbLapuI4XT-dbuXBPq-CfcN4U5hx8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Riska, Erik B. ; Holmström, Teddy</creator><creatorcontrib>Riska, Erik B. ; Holmström, Teddy</creatorcontrib><description>In 31 rabbits the femoral head was replaced by a ceramic endoprosthesis. For 11 of the experimental animals the endoprostheses were made by the Arabia China Factory in Helsinki, and for 20 by Staatliche Porzellan Manufaktur in Berlin. The operation was performed under fully sterile conditions and the follow-up time was between 6 and 34 weeks. The hip joint was examined clinically, roentgenologically, macroscopically and histologically. The bending tolerance of the ceramic endoprosthesis was not adequate. Mechanical loosening of the proximal part of the prosthesis occurred in 68 per cent and was combined with fracture of the prosthetic stem. This created a pseudarthrosis-like reaction in the acetabular area and limited the movement of the hip joint. The distal fragment of the stem was always surrounded by a thin layer of dense bone. In the nonfractured cases (32 per cent), however, the reaction was only moderate and the movement of the hip joint was well preserved. The tissue reactions to the ceramic material were slight, but the great number of secondary reactions following stem fractures make the use of the ceramic endoprosthesis questionable in experiments with rabbits.</description><identifier>ISSN: 1745-3674</identifier><identifier>ISSN: 0001-6470</identifier><identifier>EISSN: 1745-3682</identifier><identifier>DOI: 10.3109/17453678108991783</identifier><identifier>PMID: 7246100</identifier><language>eng</language><publisher>England: Informa UK Ltd</publisher><subject>Animals ; bone ; bone reactions ; ceramic endoprosthesis ; Ceramics - adverse effects ; femoral head replacement ; Follow-Up Studies ; Hip Joint - pathology ; Hip Prosthesis - instrumentation ; Rabbits</subject><ispartof>Acta orthopaedica, 1981, Vol.52 (2), p.207-213</ispartof><rights>1981 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1981</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c444t-c9e02640274f7456f11cb6577283f4dd8809560e910ab36fd8a37c835e4733143</citedby><cites>FETCH-LOGICAL-c444t-c9e02640274f7456f11cb6577283f4dd8809560e910ab36fd8a37c835e4733143</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7246100$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Riska, Erik B.</creatorcontrib><creatorcontrib>Holmström, Teddy</creatorcontrib><title>Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits</title><title>Acta orthopaedica</title><addtitle>Acta Orthop Scand</addtitle><description>In 31 rabbits the femoral head was replaced by a ceramic endoprosthesis. For 11 of the experimental animals the endoprostheses were made by the Arabia China Factory in Helsinki, and for 20 by Staatliche Porzellan Manufaktur in Berlin. The operation was performed under fully sterile conditions and the follow-up time was between 6 and 34 weeks. The hip joint was examined clinically, roentgenologically, macroscopically and histologically. The bending tolerance of the ceramic endoprosthesis was not adequate. Mechanical loosening of the proximal part of the prosthesis occurred in 68 per cent and was combined with fracture of the prosthetic stem. This created a pseudarthrosis-like reaction in the acetabular area and limited the movement of the hip joint. The distal fragment of the stem was always surrounded by a thin layer of dense bone. In the nonfractured cases (32 per cent), however, the reaction was only moderate and the movement of the hip joint was well preserved. The tissue reactions to the ceramic material were slight, but the great number of secondary reactions following stem fractures make the use of the ceramic endoprosthesis questionable in experiments with rabbits.</description><subject>Animals</subject><subject>bone</subject><subject>bone reactions</subject><subject>ceramic endoprosthesis</subject><subject>Ceramics - adverse effects</subject><subject>femoral head replacement</subject><subject>Follow-Up Studies</subject><subject>Hip Joint - pathology</subject><subject>Hip Prosthesis - instrumentation</subject><subject>Rabbits</subject><issn>1745-3674</issn><issn>0001-6470</issn><issn>1745-3682</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1981</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kF9LwzAUxYMoc04_gA9CvkA1adImVV_G2JwwEKY--VDS_GEdbVOSDu23N2VjIKJP93LP_R0OB4BrjG4JRtkdZjQhKeMY8SzDjJMTMB5uEUl5fHrcGT0HF95vESKcZmgERiymKUZoDD7Wuq2E1LVuOmgN7DYaLnRtnajgUgsFix7OtBN1KeG8UbZ11ocfX_p7OG3g_KvVrhzg8P_a7VQPbQPXoijKzl-CMyMqr68OcwLeF_O32TJavTw9z6arSFJKu0hmGsUpRTGjJuRNDcaySBPGYk4MVYpzlCUp0hlGoiCpUVwQJjlJNGWEYEomAO99ZQjnnTZ5GzIJ1-cY5UNP-a-eAnOzZ9pdUWt1JA7FBP1xr5eNsa4Wn9ZVKu9EX1lnnGhk6Qfrv-0ffuAbLapuI4XT-dbuXBPq-CfcN4U5hx8</recordid><startdate>1981</startdate><enddate>1981</enddate><creator>Riska, Erik B.</creator><creator>Holmström, Teddy</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1981</creationdate><title>Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits</title><author>Riska, Erik B. ; Holmström, Teddy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c444t-c9e02640274f7456f11cb6577283f4dd8809560e910ab36fd8a37c835e4733143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1981</creationdate><topic>Animals</topic><topic>bone</topic><topic>bone reactions</topic><topic>ceramic endoprosthesis</topic><topic>Ceramics - adverse effects</topic><topic>femoral head replacement</topic><topic>Follow-Up Studies</topic><topic>Hip Joint - pathology</topic><topic>Hip Prosthesis - instrumentation</topic><topic>Rabbits</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Riska, Erik B.</creatorcontrib><creatorcontrib>Holmström, Teddy</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Acta orthopaedica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Riska, Erik B.</au><au>Holmström, Teddy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits</atitle><jtitle>Acta orthopaedica</jtitle><addtitle>Acta Orthop Scand</addtitle><date>1981</date><risdate>1981</risdate><volume>52</volume><issue>2</issue><spage>207</spage><epage>213</epage><pages>207-213</pages><issn>1745-3674</issn><issn>0001-6470</issn><eissn>1745-3682</eissn><abstract>In 31 rabbits the femoral head was replaced by a ceramic endoprosthesis. For 11 of the experimental animals the endoprostheses were made by the Arabia China Factory in Helsinki, and for 20 by Staatliche Porzellan Manufaktur in Berlin. The operation was performed under fully sterile conditions and the follow-up time was between 6 and 34 weeks. The hip joint was examined clinically, roentgenologically, macroscopically and histologically. The bending tolerance of the ceramic endoprosthesis was not adequate. Mechanical loosening of the proximal part of the prosthesis occurred in 68 per cent and was combined with fracture of the prosthetic stem. This created a pseudarthrosis-like reaction in the acetabular area and limited the movement of the hip joint. The distal fragment of the stem was always surrounded by a thin layer of dense bone. In the nonfractured cases (32 per cent), however, the reaction was only moderate and the movement of the hip joint was well preserved. The tissue reactions to the ceramic material were slight, but the great number of secondary reactions following stem fractures make the use of the ceramic endoprosthesis questionable in experiments with rabbits.</abstract><cop>England</cop><pub>Informa UK Ltd</pub><pmid>7246100</pmid><doi>10.3109/17453678108991783</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1745-3674
ispartof Acta orthopaedica, 1981, Vol.52 (2), p.207-213
issn 1745-3674
0001-6470
1745-3682
language eng
recordid cdi_informahealthcare_journals_10_3109_17453678108991783
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Animals
bone
bone reactions
ceramic endoprosthesis
Ceramics - adverse effects
femoral head replacement
Follow-Up Studies
Hip Joint - pathology
Hip Prosthesis - instrumentation
Rabbits
title Replacement of the Femoral Head by Ceramic Endoprosthesis: An Experimental Study on Rabbits
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T01%3A47%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Replacement%20of%20the%20Femoral%20Head%20by%20Ceramic%20Endoprosthesis:%20An%20Experimental%20Study%20on%20Rabbits&rft.jtitle=Acta%20orthopaedica&rft.au=Riska,%20Erik%20B.&rft.date=1981&rft.volume=52&rft.issue=2&rft.spage=207&rft.epage=213&rft.pages=207-213&rft.issn=1745-3674&rft.eissn=1745-3682&rft_id=info:doi/10.3109/17453678108991783&rft_dat=%3Cpubmed_infor%3E7246100%3C/pubmed_infor%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/7246100&rfr_iscdi=true