Modelling the arterial wall by finite elements

Abstract The mechanical behaviour of the arterial wall was determined theoretically utilizing some parameters of blood flow measured in vivo. Continuous experimental measurements of pressure and diameter were recorded in anesthetized dogs on the thoracic ascending and midabdominal aorta. The pressur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives internationales de physiologie, de biochimie et de biophysique de biochimie et de biophysique, 1993, Vol.101 (3), p.185-191
Hauptverfasser: Mosora, F., Harmant, A., Bernard, C., Fossion, A., Pochet, T., Juchmes, J., Cescotto, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract The mechanical behaviour of the arterial wall was determined theoretically utilizing some parameters of blood flow measured in vivo. Continuous experimental measurements of pressure and diameter were recorded in anesthetized dogs on the thoracic ascending and midabdominal aorta. The pressure was measured by using a catheter, and the diameter firstly, at the same site, by a plethysmograph with mercury gauge and secondly, by a sonomicrometer with ferroelectric ceramic transducers. The unstressed radius and thickness were measured at the end of each experiment in situ. Considering that the viscous component is not important relatively to the non-linear component of the elasticity and utilizing several equations for Young modulus calculation (thick and thin wall circular cylindrical tube formulas and Bergel's equation) the following values were obtained for this parameter : 0.6 MPa-2 MPa in midabdominal aorta and 2 MPa-6.5 MPa in thoracic ascending aorta. The behaviour of the aorta wall was modelled considering an elastic law and using the finite element program "Lagamine" working in large deformations. The discretized equilibrium equations are non-linear and a unique axi-symmetric, iso-parametric element of 1 cm in length with 8 knots was used for this bi-dimensional problem. The theoretical estimation of radius vessel, utilizing a constant 5 MPa Young modulus and also a variable one, are in good agreement with the experimental results, showing that this finite element model can be applied to study mechanical properties of the arteries in physiological and pathological conditions.
ISSN:1381-3455
0778-3124
1744-4160
DOI:10.3109/13813459309046473