Comparison of Iodixanol 270 with Iohexol 300 in Infrapopliteal Arteriography

Purpose: To compare iodixanol 270 mg I ml with iohexol 300 mg I ml in infrapopliteal arteriography by measuring digital densitometric vessel opacification and by visually assessing angiographic enhancement. Material and Methods: In a double-blind, dual-balanced, 4-sequence crossover design, 50 claud...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta radiologica (1987) 1999, Vol.40 (3), p.291-295
Hauptverfasser: Manninen, Hannu I., Yang, X. M., Söder, H., Matsi, P. J., Borch, K. W., Eide, H.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To compare iodixanol 270 mg I ml with iohexol 300 mg I ml in infrapopliteal arteriography by measuring digital densitometric vessel opacification and by visually assessing angiographic enhancement. Material and Methods: In a double-blind, dual-balanced, 4-sequence crossover design, 50 claudicant patients received two contrast media injections (10 min interval) in the superficial femoral artery. Digital angiography was performed at 8 frames s and time-density curves with a circular region of interest over a distal calf artery were generated. A mixed, linear model was used to identify effects influencing the density measurements. Subjective evaluation of the image quality was made independently by two observers. Results: No statistically significant difference between the contrast media was revealed in the analysis of the densitometric measurements (p = 0.14) nor in the subjective visual evaluation (p = 0.74). However, the mean density at the time of maximum opacification was higher after the first injection than that after the second injection (p = 0.02). There was a tendency towards lower intensity of warmth during injection of iodixanol 270 than during injection of iohexol 300. Conclusion: In patients with severe occlusive atherosclerotic disease, iodixanol yielded the same image quality as iohexol in infrapopliteal arteriography, in spite of the 30 mg I ml lower iodine concentration.
ISSN:0284-1851
1600-0455
DOI:10.3109/02841859909175556