THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE

The mouse IgE test is a novel method for the prospective identification of chemicals that have the potential to cause allergic sensitization of the respiratory tract. Activity is measured as a function of increases in the concentration of total serum IgE induced by topical exposure of mice to chemic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Toxicology mechanisms and methods 1998-01, Vol.8 (2), p.69-85
Hauptverfasser: J. Dearman, R., Basketter, D. A., Blaikie, L., Clark, E. D., Hilton, J., House, R. V., Ladics, G. S., Loveless, S. E., Mattis, C., Sailstad, D. M., Sarlo, K., Selgrade, M. K., Kimber, I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 85
container_issue 2
container_start_page 69
container_title Toxicology mechanisms and methods
container_volume 8
creator J. Dearman, R.
Basketter, D. A.
Blaikie, L.
Clark, E. D.
Hilton, J.
House, R. V.
Ladics, G. S.
Loveless, S. E.
Mattis, C.
Sailstad, D. M.
Sarlo, K.
Selgrade, M. K.
Kimber, I.
description The mouse IgE test is a novel method for the prospective identification of chemicals that have the potential to cause allergic sensitization of the respiratory tract. Activity is measured as a function of increases in the concentration of total serum IgE induced by topical exposure of mice to chemicals; those chemicals that elicit a substantial elevation in IgE are classified as respiratory allergens. The present investigations were designed to evaluate further the utility of the mouse IgE test. For this purpose theassay was conducted in each of fiveindependent laboratories using trimellitic anhydride (TMA), a known cause of respiratory sensitization and occupational asthma, and 2,4-dinitrochlorobenzene (DNCB), a potent contact allergen that is considered not to cause sensitization of the respiratory tract. For these investigations BALB/c mice were used, which are currently the strain of choice for the mouse IgE test. In four of five laboratories, exposure of mice to TMA caused a statistically significant increase in the serum concentration of IgE. Under the same conditions of exposure, DNCB failed in all laboratories to induce a significant change in IgE levels compared with vehicle-treated controls. In three of five laboratories, the concentration of total serum IgE was greater in TMA- than in DNCB-treated mice. The concentration of IgE in the sera of mice exposed to vehicle alone was not significantly different from that found in untreated (naive)animals. Although thedifferential ability, in some instances, of TMA and DNCB to provoke increases in serum IgE is consistent with the results of previous investigations, it was found in all five laboratories that there existed considerable variation among individual mice within experimental groups with respect to IgE levels. These data mirrored an increasing variability in serum IgE concentrations among BALB/c strain mice found in one of the participating laboratories. For this reason mice of another strain (C57BL/6) were evaluated in the mouse IgE test by the same laboratory. The data presented here reveal that C57BL/6 mice display more stable serum IgE levels and a lower constitutive level of serum IgE but nevertheless exhibit differential responses to TMA and DNCB, with only the former causing a substantial increase in IgE concentrations. Collectively these results suggest that although the mouse IgE test continues to show some promise as an approach to the identification of chemical respiratory allergens,
doi_str_mv 10.1080/105172398242916
format Article
fullrecord <record><control><sourceid>informahealthcare_cross</sourceid><recordid>TN_cdi_informahealthcare_journals_10_1080_105172398242916</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1080_105172398242916</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-4ba79ac3876949793f75355c3bfbe9669d05e8b67898b0e4742915d71f934df03</originalsourceid><addsrcrecordid>eNp1kEtLw0AUhYMoWKtrt_MHYmcyr0x3k5jaQJpIMhVchcljbEtsZFKR_ntbKoJCV_deLt85nOM49wg-IOjDCYIUcQ8L3yOeQOzCGSGKucuoRy5_d8SunZth2ECIfETQyCnVPAKLbFlEIH6LgIoKNQVxqqI8kUGWS5XlryB6kclSqjhLgUwfQZgtnmUeF4czm4FAJsGkPj0oD5IJA4XKZZyCRRxGt86V0d3Q3v3MsbOcRSqcu0n2FIcycWtM4M4lleZC19jnTBDBBTacYkprXJmqFYyJBtLWrxj3hV_BlvBjRtpwZAQmjYF47ExOurXth8G2pvyw63dt9yWC5bGf8l8_B2J6ItZb09t3_dXbril3et_11li9rddDic_D4g-8anW3W9XatuWm_7TbQ9Szxt_78HKv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE</title><source>Taylor &amp; Francis:Master (3349 titles)</source><source>Taylor &amp; Francis Medical Library - CRKN</source><creator>J. Dearman, R. ; Basketter, D. A. ; Blaikie, L. ; Clark, E. D. ; Hilton, J. ; House, R. V. ; Ladics, G. S. ; Loveless, S. E. ; Mattis, C. ; Sailstad, D. M. ; Sarlo, K. ; Selgrade, M. K. ; Kimber, I.</creator><creatorcontrib>J. Dearman, R. ; Basketter, D. A. ; Blaikie, L. ; Clark, E. D. ; Hilton, J. ; House, R. V. ; Ladics, G. S. ; Loveless, S. E. ; Mattis, C. ; Sailstad, D. M. ; Sarlo, K. ; Selgrade, M. K. ; Kimber, I.</creatorcontrib><description>The mouse IgE test is a novel method for the prospective identification of chemicals that have the potential to cause allergic sensitization of the respiratory tract. Activity is measured as a function of increases in the concentration of total serum IgE induced by topical exposure of mice to chemicals; those chemicals that elicit a substantial elevation in IgE are classified as respiratory allergens. The present investigations were designed to evaluate further the utility of the mouse IgE test. For this purpose theassay was conducted in each of fiveindependent laboratories using trimellitic anhydride (TMA), a known cause of respiratory sensitization and occupational asthma, and 2,4-dinitrochlorobenzene (DNCB), a potent contact allergen that is considered not to cause sensitization of the respiratory tract. For these investigations BALB/c mice were used, which are currently the strain of choice for the mouse IgE test. In four of five laboratories, exposure of mice to TMA caused a statistically significant increase in the serum concentration of IgE. Under the same conditions of exposure, DNCB failed in all laboratories to induce a significant change in IgE levels compared with vehicle-treated controls. In three of five laboratories, the concentration of total serum IgE was greater in TMA- than in DNCB-treated mice. The concentration of IgE in the sera of mice exposed to vehicle alone was not significantly different from that found in untreated (naive)animals. Although thedifferential ability, in some instances, of TMA and DNCB to provoke increases in serum IgE is consistent with the results of previous investigations, it was found in all five laboratories that there existed considerable variation among individual mice within experimental groups with respect to IgE levels. These data mirrored an increasing variability in serum IgE concentrations among BALB/c strain mice found in one of the participating laboratories. For this reason mice of another strain (C57BL/6) were evaluated in the mouse IgE test by the same laboratory. The data presented here reveal that C57BL/6 mice display more stable serum IgE levels and a lower constitutive level of serum IgE but nevertheless exhibit differential responses to TMA and DNCB, with only the former causing a substantial increase in IgE concentrations. Collectively these results suggest that although the mouse IgE test continues to show some promise as an approach to the identification of chemical respiratory allergens, there is a need for careful consideration of thestrain of mouseused beforetheassay can be considered fully optimized.</description><identifier>ISSN: 1537-6516</identifier><identifier>ISSN: 1051-7235</identifier><identifier>EISSN: 1537-6524</identifier><identifier>EISSN: 1091-7667</identifier><identifier>DOI: 10.1080/105172398242916</identifier><language>eng</language><publisher>Informa UK Ltd</publisher><subject>Mouse Ige Test Respiratory Allergens Sensitization</subject><ispartof>Toxicology mechanisms and methods, 1998-01, Vol.8 (2), p.69-85</ispartof><rights>1998 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-4ba79ac3876949793f75355c3bfbe9669d05e8b67898b0e4742915d71f934df03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/105172398242916$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/105172398242916$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,59647,59753,60436,60542,61221,61256,61402,61437</link.rule.ids></links><search><creatorcontrib>J. Dearman, R.</creatorcontrib><creatorcontrib>Basketter, D. A.</creatorcontrib><creatorcontrib>Blaikie, L.</creatorcontrib><creatorcontrib>Clark, E. D.</creatorcontrib><creatorcontrib>Hilton, J.</creatorcontrib><creatorcontrib>House, R. V.</creatorcontrib><creatorcontrib>Ladics, G. S.</creatorcontrib><creatorcontrib>Loveless, S. E.</creatorcontrib><creatorcontrib>Mattis, C.</creatorcontrib><creatorcontrib>Sailstad, D. M.</creatorcontrib><creatorcontrib>Sarlo, K.</creatorcontrib><creatorcontrib>Selgrade, M. K.</creatorcontrib><creatorcontrib>Kimber, I.</creatorcontrib><title>THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE</title><title>Toxicology mechanisms and methods</title><description>The mouse IgE test is a novel method for the prospective identification of chemicals that have the potential to cause allergic sensitization of the respiratory tract. Activity is measured as a function of increases in the concentration of total serum IgE induced by topical exposure of mice to chemicals; those chemicals that elicit a substantial elevation in IgE are classified as respiratory allergens. The present investigations were designed to evaluate further the utility of the mouse IgE test. For this purpose theassay was conducted in each of fiveindependent laboratories using trimellitic anhydride (TMA), a known cause of respiratory sensitization and occupational asthma, and 2,4-dinitrochlorobenzene (DNCB), a potent contact allergen that is considered not to cause sensitization of the respiratory tract. For these investigations BALB/c mice were used, which are currently the strain of choice for the mouse IgE test. In four of five laboratories, exposure of mice to TMA caused a statistically significant increase in the serum concentration of IgE. Under the same conditions of exposure, DNCB failed in all laboratories to induce a significant change in IgE levels compared with vehicle-treated controls. In three of five laboratories, the concentration of total serum IgE was greater in TMA- than in DNCB-treated mice. The concentration of IgE in the sera of mice exposed to vehicle alone was not significantly different from that found in untreated (naive)animals. Although thedifferential ability, in some instances, of TMA and DNCB to provoke increases in serum IgE is consistent with the results of previous investigations, it was found in all five laboratories that there existed considerable variation among individual mice within experimental groups with respect to IgE levels. These data mirrored an increasing variability in serum IgE concentrations among BALB/c strain mice found in one of the participating laboratories. For this reason mice of another strain (C57BL/6) were evaluated in the mouse IgE test by the same laboratory. The data presented here reveal that C57BL/6 mice display more stable serum IgE levels and a lower constitutive level of serum IgE but nevertheless exhibit differential responses to TMA and DNCB, with only the former causing a substantial increase in IgE concentrations. Collectively these results suggest that although the mouse IgE test continues to show some promise as an approach to the identification of chemical respiratory allergens, there is a need for careful consideration of thestrain of mouseused beforetheassay can be considered fully optimized.</description><subject>Mouse Ige Test Respiratory Allergens Sensitization</subject><issn>1537-6516</issn><issn>1051-7235</issn><issn>1537-6524</issn><issn>1091-7667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNp1kEtLw0AUhYMoWKtrt_MHYmcyr0x3k5jaQJpIMhVchcljbEtsZFKR_ntbKoJCV_deLt85nOM49wg-IOjDCYIUcQ8L3yOeQOzCGSGKucuoRy5_d8SunZth2ECIfETQyCnVPAKLbFlEIH6LgIoKNQVxqqI8kUGWS5XlryB6kclSqjhLgUwfQZgtnmUeF4czm4FAJsGkPj0oD5IJA4XKZZyCRRxGt86V0d3Q3v3MsbOcRSqcu0n2FIcycWtM4M4lleZC19jnTBDBBTacYkprXJmqFYyJBtLWrxj3hV_BlvBjRtpwZAQmjYF47ExOurXth8G2pvyw63dt9yWC5bGf8l8_B2J6ItZb09t3_dXbril3et_11li9rddDic_D4g-8anW3W9XatuWm_7TbQ9Szxt_78HKv</recordid><startdate>19980101</startdate><enddate>19980101</enddate><creator>J. Dearman, R.</creator><creator>Basketter, D. A.</creator><creator>Blaikie, L.</creator><creator>Clark, E. D.</creator><creator>Hilton, J.</creator><creator>House, R. V.</creator><creator>Ladics, G. S.</creator><creator>Loveless, S. E.</creator><creator>Mattis, C.</creator><creator>Sailstad, D. M.</creator><creator>Sarlo, K.</creator><creator>Selgrade, M. K.</creator><creator>Kimber, I.</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980101</creationdate><title>THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE</title><author>J. Dearman, R. ; Basketter, D. A. ; Blaikie, L. ; Clark, E. D. ; Hilton, J. ; House, R. V. ; Ladics, G. S. ; Loveless, S. E. ; Mattis, C. ; Sailstad, D. M. ; Sarlo, K. ; Selgrade, M. K. ; Kimber, I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-4ba79ac3876949793f75355c3bfbe9669d05e8b67898b0e4742915d71f934df03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Mouse Ige Test Respiratory Allergens Sensitization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>J. Dearman, R.</creatorcontrib><creatorcontrib>Basketter, D. A.</creatorcontrib><creatorcontrib>Blaikie, L.</creatorcontrib><creatorcontrib>Clark, E. D.</creatorcontrib><creatorcontrib>Hilton, J.</creatorcontrib><creatorcontrib>House, R. V.</creatorcontrib><creatorcontrib>Ladics, G. S.</creatorcontrib><creatorcontrib>Loveless, S. E.</creatorcontrib><creatorcontrib>Mattis, C.</creatorcontrib><creatorcontrib>Sailstad, D. M.</creatorcontrib><creatorcontrib>Sarlo, K.</creatorcontrib><creatorcontrib>Selgrade, M. K.</creatorcontrib><creatorcontrib>Kimber, I.</creatorcontrib><collection>CrossRef</collection><jtitle>Toxicology mechanisms and methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>J. Dearman, R.</au><au>Basketter, D. A.</au><au>Blaikie, L.</au><au>Clark, E. D.</au><au>Hilton, J.</au><au>House, R. V.</au><au>Ladics, G. S.</au><au>Loveless, S. E.</au><au>Mattis, C.</au><au>Sailstad, D. M.</au><au>Sarlo, K.</au><au>Selgrade, M. K.</au><au>Kimber, I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE</atitle><jtitle>Toxicology mechanisms and methods</jtitle><date>1998-01-01</date><risdate>1998</risdate><volume>8</volume><issue>2</issue><spage>69</spage><epage>85</epage><pages>69-85</pages><issn>1537-6516</issn><issn>1051-7235</issn><eissn>1537-6524</eissn><eissn>1091-7667</eissn><abstract>The mouse IgE test is a novel method for the prospective identification of chemicals that have the potential to cause allergic sensitization of the respiratory tract. Activity is measured as a function of increases in the concentration of total serum IgE induced by topical exposure of mice to chemicals; those chemicals that elicit a substantial elevation in IgE are classified as respiratory allergens. The present investigations were designed to evaluate further the utility of the mouse IgE test. For this purpose theassay was conducted in each of fiveindependent laboratories using trimellitic anhydride (TMA), a known cause of respiratory sensitization and occupational asthma, and 2,4-dinitrochlorobenzene (DNCB), a potent contact allergen that is considered not to cause sensitization of the respiratory tract. For these investigations BALB/c mice were used, which are currently the strain of choice for the mouse IgE test. In four of five laboratories, exposure of mice to TMA caused a statistically significant increase in the serum concentration of IgE. Under the same conditions of exposure, DNCB failed in all laboratories to induce a significant change in IgE levels compared with vehicle-treated controls. In three of five laboratories, the concentration of total serum IgE was greater in TMA- than in DNCB-treated mice. The concentration of IgE in the sera of mice exposed to vehicle alone was not significantly different from that found in untreated (naive)animals. Although thedifferential ability, in some instances, of TMA and DNCB to provoke increases in serum IgE is consistent with the results of previous investigations, it was found in all five laboratories that there existed considerable variation among individual mice within experimental groups with respect to IgE levels. These data mirrored an increasing variability in serum IgE concentrations among BALB/c strain mice found in one of the participating laboratories. For this reason mice of another strain (C57BL/6) were evaluated in the mouse IgE test by the same laboratory. The data presented here reveal that C57BL/6 mice display more stable serum IgE levels and a lower constitutive level of serum IgE but nevertheless exhibit differential responses to TMA and DNCB, with only the former causing a substantial increase in IgE concentrations. Collectively these results suggest that although the mouse IgE test continues to show some promise as an approach to the identification of chemical respiratory allergens, there is a need for careful consideration of thestrain of mouseused beforetheassay can be considered fully optimized.</abstract><pub>Informa UK Ltd</pub><doi>10.1080/105172398242916</doi><tpages>17</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1537-6516
ispartof Toxicology mechanisms and methods, 1998-01, Vol.8 (2), p.69-85
issn 1537-6516
1051-7235
1537-6524
1091-7667
language eng
recordid cdi_informahealthcare_journals_10_1080_105172398242916
source Taylor & Francis:Master (3349 titles); Taylor & Francis Medical Library - CRKN
subjects Mouse Ige Test Respiratory Allergens Sensitization
title THE MOUSE IgE TEST: INTERLABORATORY EVALUATION AND COMPARISON OF BALB/c AND C57BL/6 STRAIN MICE
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T06%3A00%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-informahealthcare_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=THE%20MOUSE%20IgE%20TEST:%20INTERLABORATORY%20EVALUATION%20AND%20COMPARISON%20OF%20BALB/c%20AND%20C57BL/6%20STRAIN%20MICE&rft.jtitle=Toxicology%20mechanisms%20and%20methods&rft.au=J.%20Dearman,%20R.&rft.date=1998-01-01&rft.volume=8&rft.issue=2&rft.spage=69&rft.epage=85&rft.pages=69-85&rft.issn=1537-6516&rft.eissn=1537-6524&rft_id=info:doi/10.1080/105172398242916&rft_dat=%3Cinformahealthcare_cross%3E10_1080_105172398242916%3C/informahealthcare_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true