Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid
The stability of grid-connected inverters is very sensitive to varying grid impedance, especially in the weak grid condition. In this paper, based on the Lyapunov method and with the micro-grid impedance identification, an active damping adaptive control strategy is proposed to guarantee local asymp...
Gespeichert in:
Veröffentlicht in: | IEEE access 2021, Vol.9, p.132442-132454 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 132454 |
---|---|
container_issue | |
container_start_page | 132442 |
container_title | IEEE access |
container_volume | 9 |
creator | Li, Hong Ding, Xin Xue, Ruinan Li, Guojin Chen, Yanming |
description | The stability of grid-connected inverters is very sensitive to varying grid impedance, especially in the weak grid condition. In this paper, based on the Lyapunov method and with the micro-grid impedance identification, an active damping adaptive control strategy is proposed to guarantee local asymptotic stability for an LCL inverter system. First, using the backstepping design and taking the state variable errors as new variables, an appropriate Lyapunov function is constructed, so that the asymptotic stability control law can be obtained. Then, with this asymptotic stability controller, taking the varying impedance into account, an adaptive controller is developed using the Lyapunov direct method. Hence, the controller presented here can assure asymptotic stability, the system performance can also be improved instantly according to the adaptive control, and the expected stability and performance can also be achieved. Finally, the feasibility of the proposed control strategy was verified via a simulation and an experiment. |
doi_str_mv | 10.1109/ACCESS.2021.3115493 |
format | Article |
fullrecord | <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_9548038</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9548038</ieee_id><doaj_id>oai_doaj_org_article_e4f56f1d9a9e4624ad4b840a7922adb9</doaj_id><sourcerecordid>2578238515</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-4329007c2909a2270dce3d6b443d1898a89d80479c597c611881c1fed70865f93</originalsourceid><addsrcrecordid>eNpNUV1rwjAULWODyeYv8KWw57p8tslj6ZwTZHtwsscQk1upq02XVmH_ftGK7D6cG07OOQmcKJpgNMUYyee8KGar1ZQggqcUY84kvYlGBKcyoZymt__O99G463YojAgUz0bRe2766gjxi963VbONc6vbM1G4pveursHHpfPx3Fc2CVwDpgcbL5oj-D7crRsb8Av091nyGN2Vuu5gfNkP0fp19lm8JcuP-aLIl4lhSPQJo0QilJmAUhOSIWuA2nTDGLVYSKGFtAKxTBouM5NiLAQ2uASbIZHyUtKHaDHkWqd3qvXVXvtf5XSlzoTzW6V9X5kaFLCSpyW2UktgKWHaso1gSGeSEG03p6ynIav17ucAXa927uCb8H1FeCYIFRzzoKKDynjXdR7K66sYqVMPauhBnXpQlx6CazK4KgC4OiRnAlFB_wBEP4Fx</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2578238515</pqid></control><display><type>article</type><title>Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Li, Hong ; Ding, Xin ; Xue, Ruinan ; Li, Guojin ; Chen, Yanming</creator><creatorcontrib>Li, Hong ; Ding, Xin ; Xue, Ruinan ; Li, Guojin ; Chen, Yanming</creatorcontrib><description>The stability of grid-connected inverters is very sensitive to varying grid impedance, especially in the weak grid condition. In this paper, based on the Lyapunov method and with the micro-grid impedance identification, an active damping adaptive control strategy is proposed to guarantee local asymptotic stability for an LCL inverter system. First, using the backstepping design and taking the state variable errors as new variables, an appropriate Lyapunov function is constructed, so that the asymptotic stability control law can be obtained. Then, with this asymptotic stability controller, taking the varying impedance into account, an adaptive controller is developed using the Lyapunov direct method. Hence, the controller presented here can assure asymptotic stability, the system performance can also be improved instantly according to the adaptive control, and the expected stability and performance can also be achieved. Finally, the feasibility of the proposed control strategy was verified via a simulation and an experiment.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2021.3115493</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Active control ; Active damping ; Adaptive control ; Asymptotic methods ; Asymptotic properties ; Asymptotic stability ; Backstepping ; backstepping method ; Control stability ; Control theory ; Controllers ; Damping ; Distributed generation ; Impedance ; Inverters ; LCL grid-connected inverter ; Liapunov direct method ; Liapunov functions ; Lyapunov function ; Lyapunov methods ; Power system stability</subject><ispartof>IEEE access, 2021, Vol.9, p.132442-132454</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-4329007c2909a2270dce3d6b443d1898a89d80479c597c611881c1fed70865f93</citedby><cites>FETCH-LOGICAL-c408t-4329007c2909a2270dce3d6b443d1898a89d80479c597c611881c1fed70865f93</cites><orcidid>0000-0002-7123-4774 ; 0000-0001-6902-5327 ; 0000-0002-7080-4448</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9548038$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,860,2095,4009,27612,27902,27903,27904,54912</link.rule.ids></links><search><creatorcontrib>Li, Hong</creatorcontrib><creatorcontrib>Ding, Xin</creatorcontrib><creatorcontrib>Xue, Ruinan</creatorcontrib><creatorcontrib>Li, Guojin</creatorcontrib><creatorcontrib>Chen, Yanming</creatorcontrib><title>Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid</title><title>IEEE access</title><addtitle>Access</addtitle><description>The stability of grid-connected inverters is very sensitive to varying grid impedance, especially in the weak grid condition. In this paper, based on the Lyapunov method and with the micro-grid impedance identification, an active damping adaptive control strategy is proposed to guarantee local asymptotic stability for an LCL inverter system. First, using the backstepping design and taking the state variable errors as new variables, an appropriate Lyapunov function is constructed, so that the asymptotic stability control law can be obtained. Then, with this asymptotic stability controller, taking the varying impedance into account, an adaptive controller is developed using the Lyapunov direct method. Hence, the controller presented here can assure asymptotic stability, the system performance can also be improved instantly according to the adaptive control, and the expected stability and performance can also be achieved. Finally, the feasibility of the proposed control strategy was verified via a simulation and an experiment.</description><subject>Active control</subject><subject>Active damping</subject><subject>Adaptive control</subject><subject>Asymptotic methods</subject><subject>Asymptotic properties</subject><subject>Asymptotic stability</subject><subject>Backstepping</subject><subject>backstepping method</subject><subject>Control stability</subject><subject>Control theory</subject><subject>Controllers</subject><subject>Damping</subject><subject>Distributed generation</subject><subject>Impedance</subject><subject>Inverters</subject><subject>LCL grid-connected inverter</subject><subject>Liapunov direct method</subject><subject>Liapunov functions</subject><subject>Lyapunov function</subject><subject>Lyapunov methods</subject><subject>Power system stability</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNpNUV1rwjAULWODyeYv8KWw57p8tslj6ZwTZHtwsscQk1upq02XVmH_ftGK7D6cG07OOQmcKJpgNMUYyee8KGar1ZQggqcUY84kvYlGBKcyoZymt__O99G463YojAgUz0bRe2766gjxi963VbONc6vbM1G4pveursHHpfPx3Fc2CVwDpgcbL5oj-D7crRsb8Av091nyGN2Vuu5gfNkP0fp19lm8JcuP-aLIl4lhSPQJo0QilJmAUhOSIWuA2nTDGLVYSKGFtAKxTBouM5NiLAQ2uASbIZHyUtKHaDHkWqd3qvXVXvtf5XSlzoTzW6V9X5kaFLCSpyW2UktgKWHaso1gSGeSEG03p6ynIav17ucAXa927uCb8H1FeCYIFRzzoKKDynjXdR7K66sYqVMPauhBnXpQlx6CazK4KgC4OiRnAlFB_wBEP4Fx</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Li, Hong</creator><creator>Ding, Xin</creator><creator>Xue, Ruinan</creator><creator>Li, Guojin</creator><creator>Chen, Yanming</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-7123-4774</orcidid><orcidid>https://orcid.org/0000-0001-6902-5327</orcidid><orcidid>https://orcid.org/0000-0002-7080-4448</orcidid></search><sort><creationdate>2021</creationdate><title>Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid</title><author>Li, Hong ; Ding, Xin ; Xue, Ruinan ; Li, Guojin ; Chen, Yanming</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-4329007c2909a2270dce3d6b443d1898a89d80479c597c611881c1fed70865f93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Active control</topic><topic>Active damping</topic><topic>Adaptive control</topic><topic>Asymptotic methods</topic><topic>Asymptotic properties</topic><topic>Asymptotic stability</topic><topic>Backstepping</topic><topic>backstepping method</topic><topic>Control stability</topic><topic>Control theory</topic><topic>Controllers</topic><topic>Damping</topic><topic>Distributed generation</topic><topic>Impedance</topic><topic>Inverters</topic><topic>LCL grid-connected inverter</topic><topic>Liapunov direct method</topic><topic>Liapunov functions</topic><topic>Lyapunov function</topic><topic>Lyapunov methods</topic><topic>Power system stability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Hong</creatorcontrib><creatorcontrib>Ding, Xin</creatorcontrib><creatorcontrib>Xue, Ruinan</creatorcontrib><creatorcontrib>Li, Guojin</creatorcontrib><creatorcontrib>Chen, Yanming</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Hong</au><au>Ding, Xin</au><au>Xue, Ruinan</au><au>Li, Guojin</au><au>Chen, Yanming</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2021</date><risdate>2021</risdate><volume>9</volume><spage>132442</spage><epage>132454</epage><pages>132442-132454</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>The stability of grid-connected inverters is very sensitive to varying grid impedance, especially in the weak grid condition. In this paper, based on the Lyapunov method and with the micro-grid impedance identification, an active damping adaptive control strategy is proposed to guarantee local asymptotic stability for an LCL inverter system. First, using the backstepping design and taking the state variable errors as new variables, an appropriate Lyapunov function is constructed, so that the asymptotic stability control law can be obtained. Then, with this asymptotic stability controller, taking the varying impedance into account, an adaptive controller is developed using the Lyapunov direct method. Hence, the controller presented here can assure asymptotic stability, the system performance can also be improved instantly according to the adaptive control, and the expected stability and performance can also be achieved. Finally, the feasibility of the proposed control strategy was verified via a simulation and an experiment.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2021.3115493</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-7123-4774</orcidid><orcidid>https://orcid.org/0000-0001-6902-5327</orcidid><orcidid>https://orcid.org/0000-0002-7080-4448</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2169-3536 |
ispartof | IEEE access, 2021, Vol.9, p.132442-132454 |
issn | 2169-3536 2169-3536 |
language | eng |
recordid | cdi_ieee_primary_9548038 |
source | IEEE Open Access Journals; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Active control Active damping Adaptive control Asymptotic methods Asymptotic properties Asymptotic stability Backstepping backstepping method Control stability Control theory Controllers Damping Distributed generation Impedance Inverters LCL grid-connected inverter Liapunov direct method Liapunov functions Lyapunov function Lyapunov methods Power system stability |
title | Active Damping Adaptive Controller for Grid-Connected Inverter Under Weak Grid |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T11%3A41%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Active%20Damping%20Adaptive%20Controller%20for%20Grid-Connected%20Inverter%20Under%20Weak%20Grid&rft.jtitle=IEEE%20access&rft.au=Li,%20Hong&rft.date=2021&rft.volume=9&rft.spage=132442&rft.epage=132454&rft.pages=132442-132454&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2021.3115493&rft_dat=%3Cproquest_ieee_%3E2578238515%3C/proquest_ieee_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2578238515&rft_id=info:pmid/&rft_ieee_id=9548038&rft_doaj_id=oai_doaj_org_article_e4f56f1d9a9e4624ad4b840a7922adb9&rfr_iscdi=true |