Loudspeaker fault detection using time-frequency representations

This paper addresses the problem of loudspeaker testing. Two applications are investigated: loudspeaker manufacturing fault detection and maintenance. In order to comply with practical requirements, we propose a new, brief, nonstationary test signal. Recorded loudspeaker responses are processed usin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Davy, M., Cottereau, H., Doncarli, C.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper addresses the problem of loudspeaker testing. Two applications are investigated: loudspeaker manufacturing fault detection and maintenance. In order to comply with practical requirements, we propose a new, brief, nonstationary test signal. Recorded loudspeaker responses are processed using an improved time-frequency decision algorithm. The fault detection procedure is tested with real data. The results show its accuracy and practical interest.
ISSN:1520-6149
2379-190X
DOI:10.1109/ICASSP.2001.940371