Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization

The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2020, Vol.8, p.57400-57413
Hauptverfasser: Qu, Zhaoyan, Yan, Ximing, Pan, Jinxiao, Chen, Ping
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 57413
container_issue
container_start_page 57400
container_title IEEE access
container_volume 8
creator Qu, Zhaoyan
Yan, Ximing
Pan, Jinxiao
Chen, Ping
description The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its good ability to preserve sharp edges and suppress noise. However, TV-based methods often produce undesired staircase artifacts in smooth regions of the reconstructed images since the reconstructed problem is usually ill-posed and TV regularization favors piecewise constant functions. Moreover, the image can be accurately approximated by sparse coefficients under a proper wavelet tight frame, which has good capability of sparsely estimating the piecewise smooth functions and the quality of reconstructed image can be improved by the sparse prior information. To deal with sparse view CT reconstruction problem, a minimization hybrid reconstruction model that incorporates TV with the wavelet frame has been proposed, which is to use the TV-norm of the low-frequency wavelet frame coefficients and the ℓ 0 -norm of the high-frequency wavelet frame coefficients to eliminate staircase effect while maintaining sharp edges, simultaneously provide enough regularization in smooth regions. In addition, considering that the two regularization terms produce more parameters, an alternating direction method of multipliers (ADMM) algorithm has been applied to solve the minimization problem by iteratively minimization separately. Finally, compared with several iterative reconstruction methods, the experimental results demonstrate the competitiveness of the proposed method in terms of preserving edges, suppressing staircase artifacts and denoising.
doi_str_mv 10.1109/ACCESS.2020.2982229
format Article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_9043568</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9043568</ieee_id><doaj_id>oai_doaj_org_article_2032bc1fc19f4f7e885d753f3b43dc27</doaj_id><sourcerecordid>2453664582</sourcerecordid><originalsourceid>FETCH-LOGICAL-c474t-724daf0e66441e34b73a0ec2dd65c56d34e89a7a7de83c681944a675cb3b758e3</originalsourceid><addsrcrecordid>eNpNUU1rGzEQXUILDWl-QS6CnO3qW9pjuiSpwVCo3fRUxKw0a9asLVdaJ6S_vrI3hM5lhpn33gzzquqG0TljtP5y1zT3q9WcU07nvLac8_qiuuRM1zOhhP7wX_2pus55S0vY0lLmsvq9OkDKSJ56fCHNmix2sEHyA33c5zEd_djHPfkKGQMpxTqOMJAnSD2cB7AP5Bc844AjeUiwOzE3x6HM_54Bn6uPHQwZr9_yVfXz4X7dfJstvz8umrvlzEsjx5nhMkBHUWspGQrZGgEUPQ9BK690EBJtDQZMQCu8tqyWErRRvhWtURbFVbWYdEOErTukfgfp1UXo3bkR08ZBGns_oONU8NazzrO6k51Ba1UwSnSilSJ4borW7aR1SPHPEfPotvGY9uV8x2X5oZbK8oISE8qnmHPC7n0ro-5ki5tscSdb3JsthXUzsXpEfGfUVAqlrfgHoauIPw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2453664582</pqid></control><display><type>article</type><title>Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Qu, Zhaoyan ; Yan, Ximing ; Pan, Jinxiao ; Chen, Ping</creator><creatorcontrib>Qu, Zhaoyan ; Yan, Ximing ; Pan, Jinxiao ; Chen, Ping</creatorcontrib><description>The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its good ability to preserve sharp edges and suppress noise. However, TV-based methods often produce undesired staircase artifacts in smooth regions of the reconstructed images since the reconstructed problem is usually ill-posed and TV regularization favors piecewise constant functions. Moreover, the image can be accurately approximated by sparse coefficients under a proper wavelet tight frame, which has good capability of sparsely estimating the piecewise smooth functions and the quality of reconstructed image can be improved by the sparse prior information. To deal with sparse view CT reconstruction problem, a minimization hybrid reconstruction model that incorporates TV with the wavelet frame has been proposed, which is to use the TV-norm of the low-frequency wavelet frame coefficients and the ℓ 0 -norm of the high-frequency wavelet frame coefficients to eliminate staircase effect while maintaining sharp edges, simultaneously provide enough regularization in smooth regions. In addition, considering that the two regularization terms produce more parameters, an alternating direction method of multipliers (ADMM) algorithm has been applied to solve the minimization problem by iteratively minimization separately. Finally, compared with several iterative reconstruction methods, the experimental results demonstrate the competitiveness of the proposed method in terms of preserving edges, suppressing staircase artifacts and denoising.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2020.2982229</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Algorithms ; Coefficients ; Computed tomography ; Computed tomography (CT) ; Discrete wavelet transforms ; Image edge detection ; Image quality ; Image reconstruction ; iterative image reconstruction ; Iterative methods ; Medical imaging ; Noise reduction ; Optimization ; Production methods ; Radiation dosage ; Regularization ; sparse view problem ; total variation ; wavelet frame</subject><ispartof>IEEE access, 2020, Vol.8, p.57400-57413</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c474t-724daf0e66441e34b73a0ec2dd65c56d34e89a7a7de83c681944a675cb3b758e3</citedby><cites>FETCH-LOGICAL-c474t-724daf0e66441e34b73a0ec2dd65c56d34e89a7a7de83c681944a675cb3b758e3</cites><orcidid>0000-0003-0263-1984</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9043568$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,778,782,862,2098,4012,27620,27910,27911,27912,54920</link.rule.ids></links><search><creatorcontrib>Qu, Zhaoyan</creatorcontrib><creatorcontrib>Yan, Ximing</creatorcontrib><creatorcontrib>Pan, Jinxiao</creatorcontrib><creatorcontrib>Chen, Ping</creatorcontrib><title>Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization</title><title>IEEE access</title><addtitle>Access</addtitle><description>The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its good ability to preserve sharp edges and suppress noise. However, TV-based methods often produce undesired staircase artifacts in smooth regions of the reconstructed images since the reconstructed problem is usually ill-posed and TV regularization favors piecewise constant functions. Moreover, the image can be accurately approximated by sparse coefficients under a proper wavelet tight frame, which has good capability of sparsely estimating the piecewise smooth functions and the quality of reconstructed image can be improved by the sparse prior information. To deal with sparse view CT reconstruction problem, a minimization hybrid reconstruction model that incorporates TV with the wavelet frame has been proposed, which is to use the TV-norm of the low-frequency wavelet frame coefficients and the ℓ 0 -norm of the high-frequency wavelet frame coefficients to eliminate staircase effect while maintaining sharp edges, simultaneously provide enough regularization in smooth regions. In addition, considering that the two regularization terms produce more parameters, an alternating direction method of multipliers (ADMM) algorithm has been applied to solve the minimization problem by iteratively minimization separately. Finally, compared with several iterative reconstruction methods, the experimental results demonstrate the competitiveness of the proposed method in terms of preserving edges, suppressing staircase artifacts and denoising.</description><subject>Algorithms</subject><subject>Coefficients</subject><subject>Computed tomography</subject><subject>Computed tomography (CT)</subject><subject>Discrete wavelet transforms</subject><subject>Image edge detection</subject><subject>Image quality</subject><subject>Image reconstruction</subject><subject>iterative image reconstruction</subject><subject>Iterative methods</subject><subject>Medical imaging</subject><subject>Noise reduction</subject><subject>Optimization</subject><subject>Production methods</subject><subject>Radiation dosage</subject><subject>Regularization</subject><subject>sparse view problem</subject><subject>total variation</subject><subject>wavelet frame</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNpNUU1rGzEQXUILDWl-QS6CnO3qW9pjuiSpwVCo3fRUxKw0a9asLVdaJ6S_vrI3hM5lhpn33gzzquqG0TljtP5y1zT3q9WcU07nvLac8_qiuuRM1zOhhP7wX_2pus55S0vY0lLmsvq9OkDKSJ56fCHNmix2sEHyA33c5zEd_djHPfkKGQMpxTqOMJAnSD2cB7AP5Bc844AjeUiwOzE3x6HM_54Bn6uPHQwZr9_yVfXz4X7dfJstvz8umrvlzEsjx5nhMkBHUWspGQrZGgEUPQ9BK690EBJtDQZMQCu8tqyWErRRvhWtURbFVbWYdEOErTukfgfp1UXo3bkR08ZBGns_oONU8NazzrO6k51Ba1UwSnSilSJ4borW7aR1SPHPEfPotvGY9uV8x2X5oZbK8oISE8qnmHPC7n0ro-5ki5tscSdb3JsthXUzsXpEfGfUVAqlrfgHoauIPw</recordid><startdate>2020</startdate><enddate>2020</enddate><creator>Qu, Zhaoyan</creator><creator>Yan, Ximing</creator><creator>Pan, Jinxiao</creator><creator>Chen, Ping</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-0263-1984</orcidid></search><sort><creationdate>2020</creationdate><title>Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization</title><author>Qu, Zhaoyan ; Yan, Ximing ; Pan, Jinxiao ; Chen, Ping</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c474t-724daf0e66441e34b73a0ec2dd65c56d34e89a7a7de83c681944a675cb3b758e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Algorithms</topic><topic>Coefficients</topic><topic>Computed tomography</topic><topic>Computed tomography (CT)</topic><topic>Discrete wavelet transforms</topic><topic>Image edge detection</topic><topic>Image quality</topic><topic>Image reconstruction</topic><topic>iterative image reconstruction</topic><topic>Iterative methods</topic><topic>Medical imaging</topic><topic>Noise reduction</topic><topic>Optimization</topic><topic>Production methods</topic><topic>Radiation dosage</topic><topic>Regularization</topic><topic>sparse view problem</topic><topic>total variation</topic><topic>wavelet frame</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qu, Zhaoyan</creatorcontrib><creatorcontrib>Yan, Ximing</creatorcontrib><creatorcontrib>Pan, Jinxiao</creatorcontrib><creatorcontrib>Chen, Ping</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qu, Zhaoyan</au><au>Yan, Ximing</au><au>Pan, Jinxiao</au><au>Chen, Ping</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2020</date><risdate>2020</risdate><volume>8</volume><spage>57400</spage><epage>57413</epage><pages>57400-57413</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>The sparse view problem of image reconstruction encountered in computed tomography (CT) is an important research issue due to its considerable potential in lowering radiation dose. Among the researches, the total variation (TV) method is especially effective in sparse view CT reconstruction for its good ability to preserve sharp edges and suppress noise. However, TV-based methods often produce undesired staircase artifacts in smooth regions of the reconstructed images since the reconstructed problem is usually ill-posed and TV regularization favors piecewise constant functions. Moreover, the image can be accurately approximated by sparse coefficients under a proper wavelet tight frame, which has good capability of sparsely estimating the piecewise smooth functions and the quality of reconstructed image can be improved by the sparse prior information. To deal with sparse view CT reconstruction problem, a minimization hybrid reconstruction model that incorporates TV with the wavelet frame has been proposed, which is to use the TV-norm of the low-frequency wavelet frame coefficients and the ℓ 0 -norm of the high-frequency wavelet frame coefficients to eliminate staircase effect while maintaining sharp edges, simultaneously provide enough regularization in smooth regions. In addition, considering that the two regularization terms produce more parameters, an alternating direction method of multipliers (ADMM) algorithm has been applied to solve the minimization problem by iteratively minimization separately. Finally, compared with several iterative reconstruction methods, the experimental results demonstrate the competitiveness of the proposed method in terms of preserving edges, suppressing staircase artifacts and denoising.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2020.2982229</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0003-0263-1984</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2020, Vol.8, p.57400-57413
issn 2169-3536
2169-3536
language eng
recordid cdi_ieee_primary_9043568
source IEEE Open Access Journals; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Algorithms
Coefficients
Computed tomography
Computed tomography (CT)
Discrete wavelet transforms
Image edge detection
Image quality
Image reconstruction
iterative image reconstruction
Iterative methods
Medical imaging
Noise reduction
Optimization
Production methods
Radiation dosage
Regularization
sparse view problem
total variation
wavelet frame
title Sparse View CT Image Reconstruction Based on Total Variation and Wavelet Frame Regularization
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T10%3A52%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sparse%20View%20CT%20Image%20Reconstruction%20Based%20on%20Total%20Variation%20and%20Wavelet%20Frame%20Regularization&rft.jtitle=IEEE%20access&rft.au=Qu,%20Zhaoyan&rft.date=2020&rft.volume=8&rft.spage=57400&rft.epage=57413&rft.pages=57400-57413&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2020.2982229&rft_dat=%3Cproquest_ieee_%3E2453664582%3C/proquest_ieee_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2453664582&rft_id=info:pmid/&rft_ieee_id=9043568&rft_doaj_id=oai_doaj_org_article_2032bc1fc19f4f7e885d753f3b43dc27&rfr_iscdi=true