Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency

The capacitor-inductor-inductor-capacitor (CLLC) resonant converters are drawing more and more attention for their superiority in soft switching, wide output range, and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2020-10, Vol.35 (10), p.11129-11142
Hauptverfasser: Zhu, Tianhua, Zhuo, Fang, Zhao, Fangzhou, Wang, Feng, Yi, Hao, Zhao, Tong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 11142
container_issue 10
container_start_page 11129
container_title IEEE transactions on power electronics
container_volume 35
creator Zhu, Tianhua
Zhuo, Fang
Zhao, Fangzhou
Wang, Feng
Yi, Hao
Zhao, Tong
description The capacitor-inductor-inductor-capacitor (CLLC) resonant converters are drawing more and more attention for their superiority in soft switching, wide output range, and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this article proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables, and root mean square (rms) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss, and core losses of magnetic components. Besides, zero voltage switching conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18∼25 V/400 V, 200 W GaN-based CLLC resonant converter prototype.
doi_str_mv 10.1109/TPEL.2020.2978419
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_ieee_primary_9024111</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9024111</ieee_id><sourcerecordid>2419495831</sourcerecordid><originalsourceid>FETCH-LOGICAL-c336t-24058fa558b84e8e0dbc55f5ad7f186f50a92d331262431bee5e7843594e96053</originalsourceid><addsrcrecordid>eNo9kMFOAjEQhhujiYg-gPHSxPNiZ7td2qNuQEk2gSjG46bsTqEEttgtBHx6FyGe5vL9_8x8hNwD6wEw9TSdDPJezGLWi1VfJqAuSAdUAhED1r8kHSaliKRS_JrcNM2SMUgEgw7ZjzfBru2PDtbV1Bk62AesK6zoZKEbjD4W1gSauTp4t6LGeTrcrlbRi7fVHGmW5xl9x8bVuv6jdugDevplw4KO1hvvdm1TbueLEOVOV3RgjC0t1uXhllwZvWrw7jy75HM4mGZvUT5-HWXPeVRynoYoTpiQRgshZzJBiayalUIYoau-AZkawbSKK84hTuOEwwxRYPs_FypBlTLBu-Tx1Nse873FJhRLt_V1u7KIW02JEpJDS8GJKr1rGo-m2Hi71v5QACuOgouj4OIouDgLbjMPp4xFxH9esbYWgP8Cn3Z2rQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2419495831</pqid></control><display><type>article</type><title>Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency</title><source>IEEE Electronic Library (IEL)</source><creator>Zhu, Tianhua ; Zhuo, Fang ; Zhao, Fangzhou ; Wang, Feng ; Yi, Hao ; Zhao, Tong</creator><creatorcontrib>Zhu, Tianhua ; Zhuo, Fang ; Zhao, Fangzhou ; Wang, Feng ; Yi, Hao ; Zhao, Tong</creatorcontrib><description>The capacitor-inductor-inductor-capacitor (CLLC) resonant converters are drawing more and more attention for their superiority in soft switching, wide output range, and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this article proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables, and root mean square (rms) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss, and core losses of magnetic components. Besides, zero voltage switching conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18∼25 V/400 V, 200 W GaN-based CLLC resonant converter prototype.</description><identifier>ISSN: 0885-8993</identifier><identifier>EISSN: 1941-0107</identifier><identifier>DOI: 10.1109/TPEL.2020.2978419</identifier><identifier>CODEN: ITPEE8</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Bridge circuits ; Capacitors ; Capacitor–inductor–inductor–capacitor (CLLC) resonant converter ; Circuits ; Conduction losses ; Control systems ; Converters ; Core loss ; Efficiency ; extended phase-shift (EPS) control ; light-load efficiency ; Magnetic resonance ; Optimization ; Phase shift ; Power loss ; power loss evaluation ; Rectifiers ; Resonant converters ; Switches ; Switching ; Voltage control ; Voltage gain ; Zero voltage switching</subject><ispartof>IEEE transactions on power electronics, 2020-10, Vol.35 (10), p.11129-11142</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c336t-24058fa558b84e8e0dbc55f5ad7f186f50a92d331262431bee5e7843594e96053</citedby><cites>FETCH-LOGICAL-c336t-24058fa558b84e8e0dbc55f5ad7f186f50a92d331262431bee5e7843594e96053</cites><orcidid>0000-0002-5070-8942 ; 0000-0002-0194-9950 ; 0000-0002-3682-5683 ; 0000-0002-0602-7269 ; 0000-0001-9006-7740</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9024111$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/9024111$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Zhu, Tianhua</creatorcontrib><creatorcontrib>Zhuo, Fang</creatorcontrib><creatorcontrib>Zhao, Fangzhou</creatorcontrib><creatorcontrib>Wang, Feng</creatorcontrib><creatorcontrib>Yi, Hao</creatorcontrib><creatorcontrib>Zhao, Tong</creatorcontrib><title>Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency</title><title>IEEE transactions on power electronics</title><addtitle>TPEL</addtitle><description>The capacitor-inductor-inductor-capacitor (CLLC) resonant converters are drawing more and more attention for their superiority in soft switching, wide output range, and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this article proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables, and root mean square (rms) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss, and core losses of magnetic components. Besides, zero voltage switching conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18∼25 V/400 V, 200 W GaN-based CLLC resonant converter prototype.</description><subject>Bridge circuits</subject><subject>Capacitors</subject><subject>Capacitor–inductor–inductor–capacitor (CLLC) resonant converter</subject><subject>Circuits</subject><subject>Conduction losses</subject><subject>Control systems</subject><subject>Converters</subject><subject>Core loss</subject><subject>Efficiency</subject><subject>extended phase-shift (EPS) control</subject><subject>light-load efficiency</subject><subject>Magnetic resonance</subject><subject>Optimization</subject><subject>Phase shift</subject><subject>Power loss</subject><subject>power loss evaluation</subject><subject>Rectifiers</subject><subject>Resonant converters</subject><subject>Switches</subject><subject>Switching</subject><subject>Voltage control</subject><subject>Voltage gain</subject><subject>Zero voltage switching</subject><issn>0885-8993</issn><issn>1941-0107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kMFOAjEQhhujiYg-gPHSxPNiZ7td2qNuQEk2gSjG46bsTqEEttgtBHx6FyGe5vL9_8x8hNwD6wEw9TSdDPJezGLWi1VfJqAuSAdUAhED1r8kHSaliKRS_JrcNM2SMUgEgw7ZjzfBru2PDtbV1Bk62AesK6zoZKEbjD4W1gSauTp4t6LGeTrcrlbRi7fVHGmW5xl9x8bVuv6jdugDevplw4KO1hvvdm1TbueLEOVOV3RgjC0t1uXhllwZvWrw7jy75HM4mGZvUT5-HWXPeVRynoYoTpiQRgshZzJBiayalUIYoau-AZkawbSKK84hTuOEwwxRYPs_FypBlTLBu-Tx1Nse873FJhRLt_V1u7KIW02JEpJDS8GJKr1rGo-m2Hi71v5QACuOgouj4OIouDgLbjMPp4xFxH9esbYWgP8Cn3Z2rQ</recordid><startdate>20201001</startdate><enddate>20201001</enddate><creator>Zhu, Tianhua</creator><creator>Zhuo, Fang</creator><creator>Zhao, Fangzhou</creator><creator>Wang, Feng</creator><creator>Yi, Hao</creator><creator>Zhao, Tong</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-5070-8942</orcidid><orcidid>https://orcid.org/0000-0002-0194-9950</orcidid><orcidid>https://orcid.org/0000-0002-3682-5683</orcidid><orcidid>https://orcid.org/0000-0002-0602-7269</orcidid><orcidid>https://orcid.org/0000-0001-9006-7740</orcidid></search><sort><creationdate>20201001</creationdate><title>Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency</title><author>Zhu, Tianhua ; Zhuo, Fang ; Zhao, Fangzhou ; Wang, Feng ; Yi, Hao ; Zhao, Tong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c336t-24058fa558b84e8e0dbc55f5ad7f186f50a92d331262431bee5e7843594e96053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Bridge circuits</topic><topic>Capacitors</topic><topic>Capacitor–inductor–inductor–capacitor (CLLC) resonant converter</topic><topic>Circuits</topic><topic>Conduction losses</topic><topic>Control systems</topic><topic>Converters</topic><topic>Core loss</topic><topic>Efficiency</topic><topic>extended phase-shift (EPS) control</topic><topic>light-load efficiency</topic><topic>Magnetic resonance</topic><topic>Optimization</topic><topic>Phase shift</topic><topic>Power loss</topic><topic>power loss evaluation</topic><topic>Rectifiers</topic><topic>Resonant converters</topic><topic>Switches</topic><topic>Switching</topic><topic>Voltage control</topic><topic>Voltage gain</topic><topic>Zero voltage switching</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhu, Tianhua</creatorcontrib><creatorcontrib>Zhuo, Fang</creatorcontrib><creatorcontrib>Zhao, Fangzhou</creatorcontrib><creatorcontrib>Wang, Feng</creatorcontrib><creatorcontrib>Yi, Hao</creatorcontrib><creatorcontrib>Zhao, Tong</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on power electronics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Zhu, Tianhua</au><au>Zhuo, Fang</au><au>Zhao, Fangzhou</au><au>Wang, Feng</au><au>Yi, Hao</au><au>Zhao, Tong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency</atitle><jtitle>IEEE transactions on power electronics</jtitle><stitle>TPEL</stitle><date>2020-10-01</date><risdate>2020</risdate><volume>35</volume><issue>10</issue><spage>11129</spage><epage>11142</epage><pages>11129-11142</pages><issn>0885-8993</issn><eissn>1941-0107</eissn><coden>ITPEE8</coden><abstract>The capacitor-inductor-inductor-capacitor (CLLC) resonant converters are drawing more and more attention for their superiority in soft switching, wide output range, and symmetrically bidirectional operation. However, CLLC converter still suffers the problems of unsatisfactory voltage regulation and low efficiency under light-load conditions. Therefore, this article proposes an optimization for extended phase-shift (EPS) control in full-bridge CLLC resonant converter to improve the light-load efficiency. In order to study the relations between phase-shifts of EPS control and converter efficiency, a detailed circuit model is first established to solve the voltage gain, time-domain expressions of main circuit variables, and root mean square (rms) values of resonant currents. Then, a comprehensive loss evaluation is conducted by calculating and analyzing the main power losses, including conduction loss, switching loss, and core losses of magnetic components. Besides, zero voltage switching conditions of primary and rectifier switches are derived to define the range of soft switching. Finally, based on these analyses, the optimal combination of phase-shifts for EPS control is determined to achieve the maximum conversion efficiency of full-bridge CLLC converter at light-load conditions. The validity of the proposed optimized EPS control is verified on a 18∼25 V/400 V, 200 W GaN-based CLLC resonant converter prototype.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TPEL.2020.2978419</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0002-5070-8942</orcidid><orcidid>https://orcid.org/0000-0002-0194-9950</orcidid><orcidid>https://orcid.org/0000-0002-3682-5683</orcidid><orcidid>https://orcid.org/0000-0002-0602-7269</orcidid><orcidid>https://orcid.org/0000-0001-9006-7740</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0885-8993
ispartof IEEE transactions on power electronics, 2020-10, Vol.35 (10), p.11129-11142
issn 0885-8993
1941-0107
language eng
recordid cdi_ieee_primary_9024111
source IEEE Electronic Library (IEL)
subjects Bridge circuits
Capacitors
Capacitor–inductor–inductor–capacitor (CLLC) resonant converter
Circuits
Conduction losses
Control systems
Converters
Core loss
Efficiency
extended phase-shift (EPS) control
light-load efficiency
Magnetic resonance
Optimization
Phase shift
Power loss
power loss evaluation
Rectifiers
Resonant converters
Switches
Switching
Voltage control
Voltage gain
Zero voltage switching
title Optimization of Extended Phase-Shift Control for Full-Bridge CLLC Resonant Converter With Improved Light-Load Efficiency
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T23%3A10%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20Extended%20Phase-Shift%20Control%20for%20Full-Bridge%20CLLC%20Resonant%20Converter%20With%20Improved%20Light-Load%20Efficiency&rft.jtitle=IEEE%20transactions%20on%20power%20electronics&rft.au=Zhu,%20Tianhua&rft.date=2020-10-01&rft.volume=35&rft.issue=10&rft.spage=11129&rft.epage=11142&rft.pages=11129-11142&rft.issn=0885-8993&rft.eissn=1941-0107&rft.coden=ITPEE8&rft_id=info:doi/10.1109/TPEL.2020.2978419&rft_dat=%3Cproquest_RIE%3E2419495831%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2419495831&rft_id=info:pmid/&rft_ieee_id=9024111&rfr_iscdi=true