Physical evaluation of 511 keV imaging with gamma camera and PET
This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. The authors evaluate the progress in count rate which was made by upgrading the system with new electronics....
Gespeichert in:
Hauptverfasser: | , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1061 vol.2 |
---|---|
container_issue | |
container_start_page | 1057 |
container_title | |
container_volume | 2 |
creator | Vandenberghe, S. D'Asseler, Y. Koole, M. Monsieurs, M. Van de Walle, R. Lemahieu, I. Dierckx, R.A. |
description | This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. The authors evaluate the progress in count rate which was made by upgrading the system with new electronics. At the moment most gamma cameras use septa to limit the axial acceptance angle for coincidences. Sensitivity can be improved by removing the septa, which results in a fully 3D acquisition. The improvements in sensitivity are measured. Another limitation is the non-uniform sensitivity due to the varying acceptance angle, which decreases linearly from the center towards the edges in a 180/spl deg/ opposed dual head configuration. Sensitivity and uniformity can be improved by going from a dual head to a triple head configuration. As triple head coincidence is not yet available, the authors calculated the theoretical sensitivity profiles from geometrical considerations. |
doi_str_mv | 10.1109/NSSMIC.1999.845843 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_845843</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>845843</ieee_id><sourcerecordid>845843</sourcerecordid><originalsourceid>FETCH-LOGICAL-i104t-2c90b2af9ab0a9748da6d1155fcc22263e8a9c0bc341a98e8ce16ce400dbcef3</originalsourceid><addsrcrecordid>eNotj9tKw0AYhBcPYKh5gV7tCyTuOfvfKaFqoWqhwdvyZ7NJV5NUkqj07Q3UYWDguxhmCFlylnLO4O51t3tZ5ykHgNQqbZW8IJHQWZYwK-CSxJBZNltqA0ZckYjPPJFGqxsSj-MHm6W0ygyLyP32cBqDw5b6H2y_cQrHnh5rqjmnn_6dhg6b0Df0N0wH2mDXIXXY-QEp9hXdropbcl1jO_r4PxekeFwV-XOyeXta5w-bJHCmpkQ4YKXAGrBkCJmyFZqKc61r54QQRnqL4FjppOII1lvnuXFeMVaVztdyQZbn2uC9338N867htD-_l3_I00tU</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Physical evaluation of 511 keV imaging with gamma camera and PET</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Vandenberghe, S. ; D'Asseler, Y. ; Koole, M. ; Monsieurs, M. ; Van de Walle, R. ; Lemahieu, I. ; Dierckx, R.A.</creator><creatorcontrib>Vandenberghe, S. ; D'Asseler, Y. ; Koole, M. ; Monsieurs, M. ; Van de Walle, R. ; Lemahieu, I. ; Dierckx, R.A.</creatorcontrib><description>This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. The authors evaluate the progress in count rate which was made by upgrading the system with new electronics. At the moment most gamma cameras use septa to limit the axial acceptance angle for coincidences. Sensitivity can be improved by removing the septa, which results in a fully 3D acquisition. The improvements in sensitivity are measured. Another limitation is the non-uniform sensitivity due to the varying acceptance angle, which decreases linearly from the center towards the edges in a 180/spl deg/ opposed dual head configuration. Sensitivity and uniformity can be improved by going from a dual head to a triple head configuration. As triple head coincidence is not yet available, the authors calculated the theoretical sensitivity profiles from geometrical considerations.</description><identifier>ISSN: 1082-3654</identifier><identifier>ISBN: 9780780356962</identifier><identifier>ISBN: 0780356969</identifier><identifier>EISSN: 2577-0829</identifier><identifier>DOI: 10.1109/NSSMIC.1999.845843</identifier><language>eng</language><publisher>IEEE</publisher><subject>Cameras ; Collimators ; Consumer electronics ; Hospitals ; Magnetic heads ; Nuclear medicine ; Optical imaging ; Photonic crystals ; Positron emission tomography ; Shape</subject><ispartof>1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019), 1999, Vol.2, p.1057-1061 vol.2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/845843$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,4040,4041,27916,54911</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/845843$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Vandenberghe, S.</creatorcontrib><creatorcontrib>D'Asseler, Y.</creatorcontrib><creatorcontrib>Koole, M.</creatorcontrib><creatorcontrib>Monsieurs, M.</creatorcontrib><creatorcontrib>Van de Walle, R.</creatorcontrib><creatorcontrib>Lemahieu, I.</creatorcontrib><creatorcontrib>Dierckx, R.A.</creatorcontrib><title>Physical evaluation of 511 keV imaging with gamma camera and PET</title><title>1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019)</title><addtitle>NSSMIC</addtitle><description>This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. The authors evaluate the progress in count rate which was made by upgrading the system with new electronics. At the moment most gamma cameras use septa to limit the axial acceptance angle for coincidences. Sensitivity can be improved by removing the septa, which results in a fully 3D acquisition. The improvements in sensitivity are measured. Another limitation is the non-uniform sensitivity due to the varying acceptance angle, which decreases linearly from the center towards the edges in a 180/spl deg/ opposed dual head configuration. Sensitivity and uniformity can be improved by going from a dual head to a triple head configuration. As triple head coincidence is not yet available, the authors calculated the theoretical sensitivity profiles from geometrical considerations.</description><subject>Cameras</subject><subject>Collimators</subject><subject>Consumer electronics</subject><subject>Hospitals</subject><subject>Magnetic heads</subject><subject>Nuclear medicine</subject><subject>Optical imaging</subject><subject>Photonic crystals</subject><subject>Positron emission tomography</subject><subject>Shape</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>9780780356962</isbn><isbn>0780356969</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1999</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj9tKw0AYhBcPYKh5gV7tCyTuOfvfKaFqoWqhwdvyZ7NJV5NUkqj07Q3UYWDguxhmCFlylnLO4O51t3tZ5ykHgNQqbZW8IJHQWZYwK-CSxJBZNltqA0ZckYjPPJFGqxsSj-MHm6W0ygyLyP32cBqDw5b6H2y_cQrHnh5rqjmnn_6dhg6b0Df0N0wH2mDXIXXY-QEp9hXdropbcl1jO_r4PxekeFwV-XOyeXta5w-bJHCmpkQ4YKXAGrBkCJmyFZqKc61r54QQRnqL4FjppOII1lvnuXFeMVaVztdyQZbn2uC9338N867htD-_l3_I00tU</recordid><startdate>1999</startdate><enddate>1999</enddate><creator>Vandenberghe, S.</creator><creator>D'Asseler, Y.</creator><creator>Koole, M.</creator><creator>Monsieurs, M.</creator><creator>Van de Walle, R.</creator><creator>Lemahieu, I.</creator><creator>Dierckx, R.A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>1999</creationdate><title>Physical evaluation of 511 keV imaging with gamma camera and PET</title><author>Vandenberghe, S. ; D'Asseler, Y. ; Koole, M. ; Monsieurs, M. ; Van de Walle, R. ; Lemahieu, I. ; Dierckx, R.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i104t-2c90b2af9ab0a9748da6d1155fcc22263e8a9c0bc341a98e8ce16ce400dbcef3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Cameras</topic><topic>Collimators</topic><topic>Consumer electronics</topic><topic>Hospitals</topic><topic>Magnetic heads</topic><topic>Nuclear medicine</topic><topic>Optical imaging</topic><topic>Photonic crystals</topic><topic>Positron emission tomography</topic><topic>Shape</topic><toplevel>online_resources</toplevel><creatorcontrib>Vandenberghe, S.</creatorcontrib><creatorcontrib>D'Asseler, Y.</creatorcontrib><creatorcontrib>Koole, M.</creatorcontrib><creatorcontrib>Monsieurs, M.</creatorcontrib><creatorcontrib>Van de Walle, R.</creatorcontrib><creatorcontrib>Lemahieu, I.</creatorcontrib><creatorcontrib>Dierckx, R.A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vandenberghe, S.</au><au>D'Asseler, Y.</au><au>Koole, M.</au><au>Monsieurs, M.</au><au>Van de Walle, R.</au><au>Lemahieu, I.</au><au>Dierckx, R.A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Physical evaluation of 511 keV imaging with gamma camera and PET</atitle><btitle>1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019)</btitle><stitle>NSSMIC</stitle><date>1999</date><risdate>1999</risdate><volume>2</volume><spage>1057</spage><epage>1061 vol.2</epage><pages>1057-1061 vol.2</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><isbn>9780780356962</isbn><isbn>0780356969</isbn><abstract>This work presents an evaluation of a gamma camera operating in coincidence mode. The major limitations of these cameras compared to full-ring PET are the limited count rate and sensitivity. The authors evaluate the progress in count rate which was made by upgrading the system with new electronics. At the moment most gamma cameras use septa to limit the axial acceptance angle for coincidences. Sensitivity can be improved by removing the septa, which results in a fully 3D acquisition. The improvements in sensitivity are measured. Another limitation is the non-uniform sensitivity due to the varying acceptance angle, which decreases linearly from the center towards the edges in a 180/spl deg/ opposed dual head configuration. Sensitivity and uniformity can be improved by going from a dual head to a triple head configuration. As triple head coincidence is not yet available, the authors calculated the theoretical sensitivity profiles from geometrical considerations.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.1999.845843</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1082-3654 |
ispartof | 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019), 1999, Vol.2, p.1057-1061 vol.2 |
issn | 1082-3654 2577-0829 |
language | eng |
recordid | cdi_ieee_primary_845843 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Cameras Collimators Consumer electronics Hospitals Magnetic heads Nuclear medicine Optical imaging Photonic crystals Positron emission tomography Shape |
title | Physical evaluation of 511 keV imaging with gamma camera and PET |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T01%3A21%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Physical%20evaluation%20of%20511%20keV%20imaging%20with%20gamma%20camera%20and%20PET&rft.btitle=1999%20IEEE%20Nuclear%20Science%20Symposium.%20Conference%20Record.%201999%20Nuclear%20Science%20Symposium%20and%20Medical%20Imaging%20Conference%20(Cat.%20No.99CH37019)&rft.au=Vandenberghe,%20S.&rft.date=1999&rft.volume=2&rft.spage=1057&rft.epage=1061%20vol.2&rft.pages=1057-1061%20vol.2&rft.issn=1082-3654&rft.eissn=2577-0829&rft.isbn=9780780356962&rft.isbn_list=0780356969&rft_id=info:doi/10.1109/NSSMIC.1999.845843&rft_dat=%3Cieee_6IE%3E845843%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=845843&rfr_iscdi=true |