The RHIC injection system

The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported aroun...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fischer, W., Glenn, J.W., MacKay, W.W., Ptitsin, V., Robinson, T.G., Tsoupas, N.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 704 vol.2
container_issue
container_start_page 702
container_title
container_volume 2
creator Fischer, W.
Glenn, J.W.
MacKay, W.W.
Ptitsin, V.
Robinson, T.G.
Tsoupas, N.
description The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.
doi_str_mv 10.1109/PAC.1999.795327
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_795327</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>795327</ieee_id><sourcerecordid>795327</sourcerecordid><originalsourceid>FETCH-ieee_primary_7953273</originalsourceid><addsrcrecordid>eNpjYBA3NNAzNDSw1A9wdNYztLS01DO3NDU2Mmdm4DIwtzAwNjU1NzbmYOAtLs4yAAJTA3MDEwNOBsmQjFSFIA9PZ4XMvKzU5JLM_DyF4sriktRcHgbWtMSc4lReKM3NIOXmGuLsoZuZmpoaX1CUmZtYVBkPscQYryQAS3wo1w</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>The RHIC injection system</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Fischer, W. ; Glenn, J.W. ; MacKay, W.W. ; Ptitsin, V. ; Robinson, T.G. ; Tsoupas, N.</creator><creatorcontrib>Fischer, W. ; Glenn, J.W. ; MacKay, W.W. ; Ptitsin, V. ; Robinson, T.G. ; Tsoupas, N.</creatorcontrib><description>The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.</description><identifier>ISBN: 0780355733</identifier><identifier>ISBN: 9780780355736</identifier><identifier>DOI: 10.1109/PAC.1999.795327</identifier><language>eng</language><publisher>IEEE</publisher><subject>Colliding beam devices ; Extraterrestrial measurements ; Lattices ; Mirrors ; Orbits ; Particle beam injection ; Performance evaluation ; Synchrotrons ; System testing ; US Department of Energy</subject><ispartof>Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366), 1999, Vol.2, p.702-704 vol.2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/795327$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/795327$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Fischer, W.</creatorcontrib><creatorcontrib>Glenn, J.W.</creatorcontrib><creatorcontrib>MacKay, W.W.</creatorcontrib><creatorcontrib>Ptitsin, V.</creatorcontrib><creatorcontrib>Robinson, T.G.</creatorcontrib><creatorcontrib>Tsoupas, N.</creatorcontrib><title>The RHIC injection system</title><title>Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)</title><addtitle>PAC</addtitle><description>The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.</description><subject>Colliding beam devices</subject><subject>Extraterrestrial measurements</subject><subject>Lattices</subject><subject>Mirrors</subject><subject>Orbits</subject><subject>Particle beam injection</subject><subject>Performance evaluation</subject><subject>Synchrotrons</subject><subject>System testing</subject><subject>US Department of Energy</subject><isbn>0780355733</isbn><isbn>9780780355736</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1999</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpjYBA3NNAzNDSw1A9wdNYztLS01DO3NDU2Mmdm4DIwtzAwNjU1NzbmYOAtLs4yAAJTA3MDEwNOBsmQjFSFIA9PZ4XMvKzU5JLM_DyF4sriktRcHgbWtMSc4lReKM3NIOXmGuLsoZuZmpoaX1CUmZtYVBkPscQYryQAS3wo1w</recordid><startdate>1999</startdate><enddate>1999</enddate><creator>Fischer, W.</creator><creator>Glenn, J.W.</creator><creator>MacKay, W.W.</creator><creator>Ptitsin, V.</creator><creator>Robinson, T.G.</creator><creator>Tsoupas, N.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>1999</creationdate><title>The RHIC injection system</title><author>Fischer, W. ; Glenn, J.W. ; MacKay, W.W. ; Ptitsin, V. ; Robinson, T.G. ; Tsoupas, N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_7953273</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Colliding beam devices</topic><topic>Extraterrestrial measurements</topic><topic>Lattices</topic><topic>Mirrors</topic><topic>Orbits</topic><topic>Particle beam injection</topic><topic>Performance evaluation</topic><topic>Synchrotrons</topic><topic>System testing</topic><topic>US Department of Energy</topic><toplevel>online_resources</toplevel><creatorcontrib>Fischer, W.</creatorcontrib><creatorcontrib>Glenn, J.W.</creatorcontrib><creatorcontrib>MacKay, W.W.</creatorcontrib><creatorcontrib>Ptitsin, V.</creatorcontrib><creatorcontrib>Robinson, T.G.</creatorcontrib><creatorcontrib>Tsoupas, N.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Fischer, W.</au><au>Glenn, J.W.</au><au>MacKay, W.W.</au><au>Ptitsin, V.</au><au>Robinson, T.G.</au><au>Tsoupas, N.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>The RHIC injection system</atitle><btitle>Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)</btitle><stitle>PAC</stitle><date>1999</date><risdate>1999</risdate><volume>2</volume><spage>702</spage><epage>704 vol.2</epage><pages>702-704 vol.2</pages><isbn>0780355733</isbn><isbn>9780780355736</isbn><abstract>The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.</abstract><pub>IEEE</pub><doi>10.1109/PAC.1999.795327</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 0780355733
ispartof Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366), 1999, Vol.2, p.702-704 vol.2
issn
language eng
recordid cdi_ieee_primary_795327
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Colliding beam devices
Extraterrestrial measurements
Lattices
Mirrors
Orbits
Particle beam injection
Performance evaluation
Synchrotrons
System testing
US Department of Energy
title The RHIC injection system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T20%3A53%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=The%20RHIC%20injection%20system&rft.btitle=Proceedings%20of%20the%201999%20Particle%20Accelerator%20Conference%20(Cat.%20No.99CH36366)&rft.au=Fischer,%20W.&rft.date=1999&rft.volume=2&rft.spage=702&rft.epage=704%20vol.2&rft.pages=702-704%20vol.2&rft.isbn=0780355733&rft.isbn_list=9780780355736&rft_id=info:doi/10.1109/PAC.1999.795327&rft_dat=%3Cieee_6IE%3E795327%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=795327&rfr_iscdi=true