Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults

Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connecto...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2017, Vol.5, p.4221-4232
Hauptverfasser: Shen, Qinmu, Lv, Kehong, Liu, Guanjun, Qiu, Jing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4232
container_issue
container_start_page 4221
container_title IEEE access
container_volume 5
creator Shen, Qinmu
Lv, Kehong
Liu, Guanjun
Qiu, Jing
description Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connector should be measured continuously at a high sample rate. This continuous measurement requires enormous testing resources, which is impractical in engineering fields. To solve this problem, this paper proposes an on-line diagnosis method in condition of the single-end test for the electrical connector IFs. To determine the fault threshold of the electrical contact resistance (ECR), first the impact of the ECR on high-speed transmission is studied, and then the connector fault feature in condition of the single-end test, which is called the insertion loss increment (ILI), is extracted. The measurement method of the ILI is also presented. Based on the above analysis, an ILI-based on-line diagnosis method for the connector IFs is specified. According to the qualitative and quantitative tests, the proposed diagnosis method is verified. The verification results show that the cumulative insertion loss increment, which is calculated from the ILI can truly exhibit the variation of ECR, and the error of the ILI-based diagnosis method is only about 1%.
doi_str_mv 10.1109/ACCESS.2017.2679223
format Article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_7874129</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7874129</ieee_id><doaj_id>oai_doaj_org_article_720201a0ab1449f89cbe8b58c2c2a9e1</doaj_id><sourcerecordid>2455934943</sourcerecordid><originalsourceid>FETCH-LOGICAL-c474t-2ba46ff7138711439daca9d3ed97a9d36526ae8ecc3c24f95a33aab08127f3653</originalsourceid><addsrcrecordid>eNplUU1P4zAQjVa70iKWX8DF0p7TjT8Sx0cUClSqhEThbE2cSXGV2sV2D_wDfjYuQQhpfRnPm3lvxn5FcUmrBaWV-nfVdcvNZsEqKheskYox_qM4Y7RRJa958_Pb_XdxEeOuyqfNUC3PirfV_gAmET-S5YQmBWtgIp136YQ-YLQxgTNIvCPpGcmd3T6XmwPiQB4DuLi3MdpcAzeQe1eurUNybWHrfGb-r-py4gNZuYRhb1NCl8gNHKcU_xS_RpgiXnzG8-LpZvnY3ZXr-9tVd7UujZAilawH0YyjpLyVlAquBjCgBo6DkqfY1KwBbNEYbpgYVQ2cA_T5vUyOucrPi9WsO3jY6UOwewiv2oPVH4APWw0hWTOhlqzKnwoV9FQINbbK9Nj2dWuYYaCQZq2_s9Yh-JcjxqR3_hhcXl8zUdeKCyV47uJzlwk-xoDj11Ra6ZODenZQnxzUnw5m1uXMsoj4xZCtFJQp_g4k9phx</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2455934943</pqid></control><display><type>article</type><title>Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults</title><source>IEEE Open Access Journals</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Shen, Qinmu ; Lv, Kehong ; Liu, Guanjun ; Qiu, Jing</creator><creatorcontrib>Shen, Qinmu ; Lv, Kehong ; Liu, Guanjun ; Qiu, Jing</creatorcontrib><description>Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connector should be measured continuously at a high sample rate. This continuous measurement requires enormous testing resources, which is impractical in engineering fields. To solve this problem, this paper proposes an on-line diagnosis method in condition of the single-end test for the electrical connector IFs. To determine the fault threshold of the electrical contact resistance (ECR), first the impact of the ECR on high-speed transmission is studied, and then the connector fault feature in condition of the single-end test, which is called the insertion loss increment (ILI), is extracted. The measurement method of the ILI is also presented. Based on the above analysis, an ILI-based on-line diagnosis method for the connector IFs is specified. According to the qualitative and quantitative tests, the proposed diagnosis method is verified. The verification results show that the cumulative insertion loss increment, which is calculated from the ILI can truly exhibit the variation of ECR, and the error of the ILI-based diagnosis method is only about 1%.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2017.2679223</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Connectors ; Contact resistance ; Contacts ; Electric connectors ; Electric contacts ; Electrical connector ; electrical contact resistance ; Electrical resistance ; Equivalent circuits ; Fault diagnosis ; High speed ; high-speed signal ; Impact resistance ; Impedance ; Insertion loss ; intermittent fault ; Measurement methods ; on-line diagnosis ; Power transmission lines ; Resistance ; Transmission line matrix methods ; Voltage drop</subject><ispartof>IEEE access, 2017, Vol.5, p.4221-4232</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c474t-2ba46ff7138711439daca9d3ed97a9d36526ae8ecc3c24f95a33aab08127f3653</citedby><cites>FETCH-LOGICAL-c474t-2ba46ff7138711439daca9d3ed97a9d36526ae8ecc3c24f95a33aab08127f3653</cites><orcidid>0000-0003-4873-0929</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7874129$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,860,2095,4009,27612,27902,27903,27904,54912</link.rule.ids></links><search><creatorcontrib>Shen, Qinmu</creatorcontrib><creatorcontrib>Lv, Kehong</creatorcontrib><creatorcontrib>Liu, Guanjun</creatorcontrib><creatorcontrib>Qiu, Jing</creatorcontrib><title>Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults</title><title>IEEE access</title><addtitle>Access</addtitle><description>Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connector should be measured continuously at a high sample rate. This continuous measurement requires enormous testing resources, which is impractical in engineering fields. To solve this problem, this paper proposes an on-line diagnosis method in condition of the single-end test for the electrical connector IFs. To determine the fault threshold of the electrical contact resistance (ECR), first the impact of the ECR on high-speed transmission is studied, and then the connector fault feature in condition of the single-end test, which is called the insertion loss increment (ILI), is extracted. The measurement method of the ILI is also presented. Based on the above analysis, an ILI-based on-line diagnosis method for the connector IFs is specified. According to the qualitative and quantitative tests, the proposed diagnosis method is verified. The verification results show that the cumulative insertion loss increment, which is calculated from the ILI can truly exhibit the variation of ECR, and the error of the ILI-based diagnosis method is only about 1%.</description><subject>Connectors</subject><subject>Contact resistance</subject><subject>Contacts</subject><subject>Electric connectors</subject><subject>Electric contacts</subject><subject>Electrical connector</subject><subject>electrical contact resistance</subject><subject>Electrical resistance</subject><subject>Equivalent circuits</subject><subject>Fault diagnosis</subject><subject>High speed</subject><subject>high-speed signal</subject><subject>Impact resistance</subject><subject>Impedance</subject><subject>Insertion loss</subject><subject>intermittent fault</subject><subject>Measurement methods</subject><subject>on-line diagnosis</subject><subject>Power transmission lines</subject><subject>Resistance</subject><subject>Transmission line matrix methods</subject><subject>Voltage drop</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>DOA</sourceid><recordid>eNplUU1P4zAQjVa70iKWX8DF0p7TjT8Sx0cUClSqhEThbE2cSXGV2sV2D_wDfjYuQQhpfRnPm3lvxn5FcUmrBaWV-nfVdcvNZsEqKheskYox_qM4Y7RRJa958_Pb_XdxEeOuyqfNUC3PirfV_gAmET-S5YQmBWtgIp136YQ-YLQxgTNIvCPpGcmd3T6XmwPiQB4DuLi3MdpcAzeQe1eurUNybWHrfGb-r-py4gNZuYRhb1NCl8gNHKcU_xS_RpgiXnzG8-LpZvnY3ZXr-9tVd7UujZAilawH0YyjpLyVlAquBjCgBo6DkqfY1KwBbNEYbpgYVQ2cA_T5vUyOucrPi9WsO3jY6UOwewiv2oPVH4APWw0hWTOhlqzKnwoV9FQINbbK9Nj2dWuYYaCQZq2_s9Yh-JcjxqR3_hhcXl8zUdeKCyV47uJzlwk-xoDj11Ra6ZODenZQnxzUnw5m1uXMsoj4xZCtFJQp_g4k9phx</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Shen, Qinmu</creator><creator>Lv, Kehong</creator><creator>Liu, Guanjun</creator><creator>Qiu, Jing</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-4873-0929</orcidid></search><sort><creationdate>2017</creationdate><title>Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults</title><author>Shen, Qinmu ; Lv, Kehong ; Liu, Guanjun ; Qiu, Jing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c474t-2ba46ff7138711439daca9d3ed97a9d36526ae8ecc3c24f95a33aab08127f3653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Connectors</topic><topic>Contact resistance</topic><topic>Contacts</topic><topic>Electric connectors</topic><topic>Electric contacts</topic><topic>Electrical connector</topic><topic>electrical contact resistance</topic><topic>Electrical resistance</topic><topic>Equivalent circuits</topic><topic>Fault diagnosis</topic><topic>High speed</topic><topic>high-speed signal</topic><topic>Impact resistance</topic><topic>Impedance</topic><topic>Insertion loss</topic><topic>intermittent fault</topic><topic>Measurement methods</topic><topic>on-line diagnosis</topic><topic>Power transmission lines</topic><topic>Resistance</topic><topic>Transmission line matrix methods</topic><topic>Voltage drop</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shen, Qinmu</creatorcontrib><creatorcontrib>Lv, Kehong</creatorcontrib><creatorcontrib>Liu, Guanjun</creatorcontrib><creatorcontrib>Qiu, Jing</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shen, Qinmu</au><au>Lv, Kehong</au><au>Liu, Guanjun</au><au>Qiu, Jing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2017</date><risdate>2017</risdate><volume>5</volume><spage>4221</spage><epage>4232</epage><pages>4221-4232</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>Electrical connectors are widely used in many kinds of main equipment. It is very difficult, costly, and time consuming for the off-line diagnosis of intermittent faults (IFs) in connectors. To realize the on-line diagnosis by the traditional method, the voltage drop between two ends of the connector should be measured continuously at a high sample rate. This continuous measurement requires enormous testing resources, which is impractical in engineering fields. To solve this problem, this paper proposes an on-line diagnosis method in condition of the single-end test for the electrical connector IFs. To determine the fault threshold of the electrical contact resistance (ECR), first the impact of the ECR on high-speed transmission is studied, and then the connector fault feature in condition of the single-end test, which is called the insertion loss increment (ILI), is extracted. The measurement method of the ILI is also presented. Based on the above analysis, an ILI-based on-line diagnosis method for the connector IFs is specified. According to the qualitative and quantitative tests, the proposed diagnosis method is verified. The verification results show that the cumulative insertion loss increment, which is calculated from the ILI can truly exhibit the variation of ECR, and the error of the ILI-based diagnosis method is only about 1%.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2017.2679223</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-4873-0929</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2017, Vol.5, p.4221-4232
issn 2169-3536
2169-3536
language eng
recordid cdi_ieee_primary_7874129
source IEEE Open Access Journals; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Connectors
Contact resistance
Contacts
Electric connectors
Electric contacts
Electrical connector
electrical contact resistance
Electrical resistance
Equivalent circuits
Fault diagnosis
High speed
high-speed signal
Impact resistance
Impedance
Insertion loss
intermittent fault
Measurement methods
on-line diagnosis
Power transmission lines
Resistance
Transmission line matrix methods
Voltage drop
title Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent Faults
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T22%3A41%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20Electrical%20Contact%20Resistance%20on%20the%20High-Speed%20Transmission%20and%20On-Line%20Diagnosis%20of%20Electrical%20Connector%20Intermittent%20Faults&rft.jtitle=IEEE%20access&rft.au=Shen,%20Qinmu&rft.date=2017&rft.volume=5&rft.spage=4221&rft.epage=4232&rft.pages=4221-4232&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2017.2679223&rft_dat=%3Cproquest_ieee_%3E2455934943%3C/proquest_ieee_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2455934943&rft_id=info:pmid/&rft_ieee_id=7874129&rft_doaj_id=oai_doaj_org_article_720201a0ab1449f89cbe8b58c2c2a9e1&rfr_iscdi=true