Effect of sample rate on saECG spectrum

Signal-averaged ECG (saECG) has been used to show delayed ventricular activation and myocardial infarction, but alignment jitter acts as a low-pass filter. Jitter arises due to sampling of the signal, and due to imperfect alignment algorithms. In this study we investigated the influence of the sampl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Melgaard, Jacob, Graff, Claus, Sorensen, Peter L., Sorensen, Kasper, Schmidt, Samuel E., Struijk, Johannes J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1063
container_issue
container_start_page 1061
container_title
container_volume
creator Melgaard, Jacob
Graff, Claus
Sorensen, Peter L.
Sorensen, Kasper
Schmidt, Samuel E.
Struijk, Johannes J.
description Signal-averaged ECG (saECG) has been used to show delayed ventricular activation and myocardial infarction, but alignment jitter acts as a low-pass filter. Jitter arises due to sampling of the signal, and due to imperfect alignment algorithms. In this study we investigated the influence of the sample rate on the saECG spectrum, i.e. if the jitter can be minimized by increasing the sample rate. High speed high resolution ECGs were recorded from 6 volunteers in a shielded room. The spectrum of both raw beats and the saECG were computed and compared, and we found that sample rate does indeed influence the intrinsic low-pass filtering of the signal caused by jitter.
doi_str_mv 10.22489/cinc.2016.306-499
format Conference Proceeding
fullrecord <record><control><sourceid>ieee</sourceid><recordid>TN_cdi_ieee_primary_7868929</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7868929</ieee_id><sourcerecordid>7868929</sourcerecordid><originalsourceid>FETCH-LOGICAL-i219t-ae8933fe6127d3bccf857f304b1ed31e35ec75ff435f38a545978fb05f940be33</originalsourceid><addsrcrecordid>eNotjkFLw0AQhVdBsNT8Ab3k5ilxd2c3O3OUEFuh4KUFb2WznYFI04YkHvz3BvRdHh8PPp5Sj0aX1jqkl9RdUmm1qUrQVeGIblRGAY3XpDWSD7dqZcH6AjF83qtsmr70Eh-QKlyp50aE05xfJZ9iP5w5H-PM-fWyYFNv8mlY1vG7f1B3Es8TZ_-9Voe3Zl9vi93H5r1-3RWdNTQXkZEAhCtjwwnalAR9ENCuNXwCw-A5BS_iwAtg9M4vX6XVXsjplgHW6unP2zHzcRi7Po4_x4AVkiX4BdHiQT0</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Effect of sample rate on saECG spectrum</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Melgaard, Jacob ; Graff, Claus ; Sorensen, Peter L. ; Sorensen, Kasper ; Schmidt, Samuel E. ; Struijk, Johannes J.</creator><creatorcontrib>Melgaard, Jacob ; Graff, Claus ; Sorensen, Peter L. ; Sorensen, Kasper ; Schmidt, Samuel E. ; Struijk, Johannes J.</creatorcontrib><description>Signal-averaged ECG (saECG) has been used to show delayed ventricular activation and myocardial infarction, but alignment jitter acts as a low-pass filter. Jitter arises due to sampling of the signal, and due to imperfect alignment algorithms. In this study we investigated the influence of the sample rate on the saECG spectrum, i.e. if the jitter can be minimized by increasing the sample rate. High speed high resolution ECGs were recorded from 6 volunteers in a shielded room. The spectrum of both raw beats and the saECG were computed and compared, and we found that sample rate does indeed influence the intrinsic low-pass filtering of the signal caused by jitter.</description><identifier>EISSN: 2325-887X</identifier><identifier>EISBN: 9781509008957</identifier><identifier>EISBN: 1509008950</identifier><identifier>DOI: 10.22489/cinc.2016.306-499</identifier><language>eng</language><publisher>CCAL</publisher><subject>Attenuation ; Cutoff frequency ; Electrocardiography ; Jitter ; Lead ; Low-pass filters</subject><ispartof>2016 Computing in Cardiology Conference (CinC), 2016, p.1061-1063</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,780,784,789,790,27925</link.rule.ids></links><search><creatorcontrib>Melgaard, Jacob</creatorcontrib><creatorcontrib>Graff, Claus</creatorcontrib><creatorcontrib>Sorensen, Peter L.</creatorcontrib><creatorcontrib>Sorensen, Kasper</creatorcontrib><creatorcontrib>Schmidt, Samuel E.</creatorcontrib><creatorcontrib>Struijk, Johannes J.</creatorcontrib><title>Effect of sample rate on saECG spectrum</title><title>2016 Computing in Cardiology Conference (CinC)</title><addtitle>CIC</addtitle><description>Signal-averaged ECG (saECG) has been used to show delayed ventricular activation and myocardial infarction, but alignment jitter acts as a low-pass filter. Jitter arises due to sampling of the signal, and due to imperfect alignment algorithms. In this study we investigated the influence of the sample rate on the saECG spectrum, i.e. if the jitter can be minimized by increasing the sample rate. High speed high resolution ECGs were recorded from 6 volunteers in a shielded room. The spectrum of both raw beats and the saECG were computed and compared, and we found that sample rate does indeed influence the intrinsic low-pass filtering of the signal caused by jitter.</description><subject>Attenuation</subject><subject>Cutoff frequency</subject><subject>Electrocardiography</subject><subject>Jitter</subject><subject>Lead</subject><subject>Low-pass filters</subject><issn>2325-887X</issn><isbn>9781509008957</isbn><isbn>1509008950</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2016</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotjkFLw0AQhVdBsNT8Ab3k5ilxd2c3O3OUEFuh4KUFb2WznYFI04YkHvz3BvRdHh8PPp5Sj0aX1jqkl9RdUmm1qUrQVeGIblRGAY3XpDWSD7dqZcH6AjF83qtsmr70Eh-QKlyp50aE05xfJZ9iP5w5H-PM-fWyYFNv8mlY1vG7f1B3Es8TZ_-9Voe3Zl9vi93H5r1-3RWdNTQXkZEAhCtjwwnalAR9ENCuNXwCw-A5BS_iwAtg9M4vX6XVXsjplgHW6unP2zHzcRi7Po4_x4AVkiX4BdHiQT0</recordid><startdate>201609</startdate><enddate>201609</enddate><creator>Melgaard, Jacob</creator><creator>Graff, Claus</creator><creator>Sorensen, Peter L.</creator><creator>Sorensen, Kasper</creator><creator>Schmidt, Samuel E.</creator><creator>Struijk, Johannes J.</creator><general>CCAL</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201609</creationdate><title>Effect of sample rate on saECG spectrum</title><author>Melgaard, Jacob ; Graff, Claus ; Sorensen, Peter L. ; Sorensen, Kasper ; Schmidt, Samuel E. ; Struijk, Johannes J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i219t-ae8933fe6127d3bccf857f304b1ed31e35ec75ff435f38a545978fb05f940be33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Attenuation</topic><topic>Cutoff frequency</topic><topic>Electrocardiography</topic><topic>Jitter</topic><topic>Lead</topic><topic>Low-pass filters</topic><toplevel>online_resources</toplevel><creatorcontrib>Melgaard, Jacob</creatorcontrib><creatorcontrib>Graff, Claus</creatorcontrib><creatorcontrib>Sorensen, Peter L.</creatorcontrib><creatorcontrib>Sorensen, Kasper</creatorcontrib><creatorcontrib>Schmidt, Samuel E.</creatorcontrib><creatorcontrib>Struijk, Johannes J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Melgaard, Jacob</au><au>Graff, Claus</au><au>Sorensen, Peter L.</au><au>Sorensen, Kasper</au><au>Schmidt, Samuel E.</au><au>Struijk, Johannes J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Effect of sample rate on saECG spectrum</atitle><btitle>2016 Computing in Cardiology Conference (CinC)</btitle><stitle>CIC</stitle><date>2016-09</date><risdate>2016</risdate><spage>1061</spage><epage>1063</epage><pages>1061-1063</pages><eissn>2325-887X</eissn><eisbn>9781509008957</eisbn><eisbn>1509008950</eisbn><abstract>Signal-averaged ECG (saECG) has been used to show delayed ventricular activation and myocardial infarction, but alignment jitter acts as a low-pass filter. Jitter arises due to sampling of the signal, and due to imperfect alignment algorithms. In this study we investigated the influence of the sample rate on the saECG spectrum, i.e. if the jitter can be minimized by increasing the sample rate. High speed high resolution ECGs were recorded from 6 volunteers in a shielded room. The spectrum of both raw beats and the saECG were computed and compared, and we found that sample rate does indeed influence the intrinsic low-pass filtering of the signal caused by jitter.</abstract><pub>CCAL</pub><doi>10.22489/cinc.2016.306-499</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2325-887X
ispartof 2016 Computing in Cardiology Conference (CinC), 2016, p.1061-1063
issn 2325-887X
language eng
recordid cdi_ieee_primary_7868929
source EZB-FREE-00999 freely available EZB journals
subjects Attenuation
Cutoff frequency
Electrocardiography
Jitter
Lead
Low-pass filters
title Effect of sample rate on saECG spectrum
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T20%3A01%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Effect%20of%20sample%20rate%20on%20saECG%20spectrum&rft.btitle=2016%20Computing%20in%20Cardiology%20Conference%20(CinC)&rft.au=Melgaard,%20Jacob&rft.date=2016-09&rft.spage=1061&rft.epage=1063&rft.pages=1061-1063&rft.eissn=2325-887X&rft_id=info:doi/10.22489/cinc.2016.306-499&rft_dat=%3Cieee%3E7868929%3C/ieee%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781509008957&rft.eisbn_list=1509008950&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7868929&rfr_iscdi=true