Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching

A new "double clamp methodology" (DCM) is proposed that can suppress a cable's peak radiated emission in a band centered around noise frequency (f noise pk ) that is generated by common-mode (CM) electrical noise current flowing in any product containing pulsed switching devices conne...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2017-01, Vol.53 (1), p.327-339
Hauptverfasser: Vrankovic, Zoran, Skibinski, Gary L., Winterhalter, Craig
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 339
container_issue 1
container_start_page 327
container_title IEEE transactions on industry applications
container_volume 53
creator Vrankovic, Zoran
Skibinski, Gary L.
Winterhalter, Craig
description A new "double clamp methodology" (DCM) is proposed that can suppress a cable's peak radiated emission in a band centered around noise frequency (f noise pk ) that is generated by common-mode (CM) electrical noise current flowing in any product containing pulsed switching devices connected to a shielded cable. DCM is a cable grounding technique that clamps or terminates a shielded cable in two places. The first shield clamp at the switching device output uses traditional well-known cable termination techniques, e.g., 360° low inductance shield connection to ground. A second shield clamp can be placed at a predetermined cable length from the first, where the cable resonant frequency is known to have ultralow CM impedance at noise frequency f noise pk . The cable loop between shield clamp terminations sets up a resonant low impedance at f noise pk that diverts CM current to the ground plane inside the product, so CM current entering a shielded cable is reduced as well as radiated electric field emissions. Analytical and measurement techniques are provided to determine the correct cable clamp length. Experimental test results confirm DCM effectively controls CM noise current and resulting peak radiated emissions by 12 dB·μV/m (~4×), without external suppression components added.
doi_str_mv 10.1109/TIA.2016.2614634
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_7579626</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7579626</ieee_id><sourcerecordid>10_1109_TIA_2016_2614634</sourcerecordid><originalsourceid>FETCH-LOGICAL-c263t-26df71f349f5073c1f869d00b6e9aa2b50681b0272aa9dd54c8ee6ab39fce5e13</originalsourceid><addsrcrecordid>eNo9kFFLwzAUhYMoOKfvgi_5A51Jk6bL4-imFqbCnM8lTW62SNaMppvs39uy4dPhHs45XD6EHimZUErk87qcTVJCxSQVlAvGr9CISiYTyUR-jUaESJZIKfktuovxhxDKM8pHKH6EI3g8D4faAy682u3xO3TbYIIPmxPuAl6BOWjAX1sH3oDBhRqiK2Wc6vpzsXMxutBEXDauO3v1CS886K4NjdN4Dkc3DPy6Tm9ds7lHN1b5CA8XHaPvl8W6eEuWn69lMVsmOhWsS1JhbE4t49JmJGea2qmQhpBagFQqrTMiprQmaZ4qJY3JuJ4CCFUzaTVkQNkYkfOubkOMLdhq37qdak8VJdUAreqhVQO06gKtrzydKw4A_uN5lkvR__QH6sFp9A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching</title><source>IEEE Xplore (Online service)</source><creator>Vrankovic, Zoran ; Skibinski, Gary L. ; Winterhalter, Craig</creator><creatorcontrib>Vrankovic, Zoran ; Skibinski, Gary L. ; Winterhalter, Craig</creatorcontrib><description>A new "double clamp methodology" (DCM) is proposed that can suppress a cable's peak radiated emission in a band centered around noise frequency (f noise pk ) that is generated by common-mode (CM) electrical noise current flowing in any product containing pulsed switching devices connected to a shielded cable. DCM is a cable grounding technique that clamps or terminates a shielded cable in two places. The first shield clamp at the switching device output uses traditional well-known cable termination techniques, e.g., 360° low inductance shield connection to ground. A second shield clamp can be placed at a predetermined cable length from the first, where the cable resonant frequency is known to have ultralow CM impedance at noise frequency f noise pk . The cable loop between shield clamp terminations sets up a resonant low impedance at f noise pk that diverts CM current to the ground plane inside the product, so CM current entering a shielded cable is reduced as well as radiated electric field emissions. Analytical and measurement techniques are provided to determine the correct cable clamp length. Experimental test results confirm DCM effectively controls CM noise current and resulting peak radiated emissions by 12 dB·μV/m (~4×), without external suppression components added.</description><identifier>ISSN: 0093-9994</identifier><identifier>EISSN: 1939-9367</identifier><identifier>DOI: 10.1109/TIA.2016.2614634</identifier><identifier>CODEN: ITIACR</identifier><language>eng</language><publisher>IEEE</publisher><subject>Adjustable-speed drives (ASD) ; Cable shielding ; Clamps ; common-mode (CM) current ; Current measurement ; double clamp methodology (DCM) ; electromagnetic compatibility (EMC) ; Impedance ; Power cables ; radiated electromagnetic interference (EMI) ; Switched-mode power supply ; switching converters ; Variable speed drives</subject><ispartof>IEEE transactions on industry applications, 2017-01, Vol.53 (1), p.327-339</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c263t-26df71f349f5073c1f869d00b6e9aa2b50681b0272aa9dd54c8ee6ab39fce5e13</citedby><cites>FETCH-LOGICAL-c263t-26df71f349f5073c1f869d00b6e9aa2b50681b0272aa9dd54c8ee6ab39fce5e13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7579626$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27903,27904,54737</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/7579626$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Vrankovic, Zoran</creatorcontrib><creatorcontrib>Skibinski, Gary L.</creatorcontrib><creatorcontrib>Winterhalter, Craig</creatorcontrib><title>Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching</title><title>IEEE transactions on industry applications</title><addtitle>TIA</addtitle><description>A new "double clamp methodology" (DCM) is proposed that can suppress a cable's peak radiated emission in a band centered around noise frequency (f noise pk ) that is generated by common-mode (CM) electrical noise current flowing in any product containing pulsed switching devices connected to a shielded cable. DCM is a cable grounding technique that clamps or terminates a shielded cable in two places. The first shield clamp at the switching device output uses traditional well-known cable termination techniques, e.g., 360° low inductance shield connection to ground. A second shield clamp can be placed at a predetermined cable length from the first, where the cable resonant frequency is known to have ultralow CM impedance at noise frequency f noise pk . The cable loop between shield clamp terminations sets up a resonant low impedance at f noise pk that diverts CM current to the ground plane inside the product, so CM current entering a shielded cable is reduced as well as radiated electric field emissions. Analytical and measurement techniques are provided to determine the correct cable clamp length. Experimental test results confirm DCM effectively controls CM noise current and resulting peak radiated emissions by 12 dB·μV/m (~4×), without external suppression components added.</description><subject>Adjustable-speed drives (ASD)</subject><subject>Cable shielding</subject><subject>Clamps</subject><subject>common-mode (CM) current</subject><subject>Current measurement</subject><subject>double clamp methodology (DCM)</subject><subject>electromagnetic compatibility (EMC)</subject><subject>Impedance</subject><subject>Power cables</subject><subject>radiated electromagnetic interference (EMI)</subject><subject>Switched-mode power supply</subject><subject>switching converters</subject><subject>Variable speed drives</subject><issn>0093-9994</issn><issn>1939-9367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kFFLwzAUhYMoOKfvgi_5A51Jk6bL4-imFqbCnM8lTW62SNaMppvs39uy4dPhHs45XD6EHimZUErk87qcTVJCxSQVlAvGr9CISiYTyUR-jUaESJZIKfktuovxhxDKM8pHKH6EI3g8D4faAy682u3xO3TbYIIPmxPuAl6BOWjAX1sH3oDBhRqiK2Wc6vpzsXMxutBEXDauO3v1CS886K4NjdN4Dkc3DPy6Tm9ds7lHN1b5CA8XHaPvl8W6eEuWn69lMVsmOhWsS1JhbE4t49JmJGea2qmQhpBagFQqrTMiprQmaZ4qJY3JuJ4CCFUzaTVkQNkYkfOubkOMLdhq37qdak8VJdUAreqhVQO06gKtrzydKw4A_uN5lkvR__QH6sFp9A</recordid><startdate>201701</startdate><enddate>201701</enddate><creator>Vrankovic, Zoran</creator><creator>Skibinski, Gary L.</creator><creator>Winterhalter, Craig</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201701</creationdate><title>Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching</title><author>Vrankovic, Zoran ; Skibinski, Gary L. ; Winterhalter, Craig</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c263t-26df71f349f5073c1f869d00b6e9aa2b50681b0272aa9dd54c8ee6ab39fce5e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Adjustable-speed drives (ASD)</topic><topic>Cable shielding</topic><topic>Clamps</topic><topic>common-mode (CM) current</topic><topic>Current measurement</topic><topic>double clamp methodology (DCM)</topic><topic>electromagnetic compatibility (EMC)</topic><topic>Impedance</topic><topic>Power cables</topic><topic>radiated electromagnetic interference (EMI)</topic><topic>Switched-mode power supply</topic><topic>switching converters</topic><topic>Variable speed drives</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vrankovic, Zoran</creatorcontrib><creatorcontrib>Skibinski, Gary L.</creatorcontrib><creatorcontrib>Winterhalter, Craig</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005–Present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Xplore (Online service)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on industry applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vrankovic, Zoran</au><au>Skibinski, Gary L.</au><au>Winterhalter, Craig</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching</atitle><jtitle>IEEE transactions on industry applications</jtitle><stitle>TIA</stitle><date>2017-01</date><risdate>2017</risdate><volume>53</volume><issue>1</issue><spage>327</spage><epage>339</epage><pages>327-339</pages><issn>0093-9994</issn><eissn>1939-9367</eissn><coden>ITIACR</coden><abstract>A new "double clamp methodology" (DCM) is proposed that can suppress a cable's peak radiated emission in a band centered around noise frequency (f noise pk ) that is generated by common-mode (CM) electrical noise current flowing in any product containing pulsed switching devices connected to a shielded cable. DCM is a cable grounding technique that clamps or terminates a shielded cable in two places. The first shield clamp at the switching device output uses traditional well-known cable termination techniques, e.g., 360° low inductance shield connection to ground. A second shield clamp can be placed at a predetermined cable length from the first, where the cable resonant frequency is known to have ultralow CM impedance at noise frequency f noise pk . The cable loop between shield clamp terminations sets up a resonant low impedance at f noise pk that diverts CM current to the ground plane inside the product, so CM current entering a shielded cable is reduced as well as radiated electric field emissions. Analytical and measurement techniques are provided to determine the correct cable clamp length. Experimental test results confirm DCM effectively controls CM noise current and resulting peak radiated emissions by 12 dB·μV/m (~4×), without external suppression components added.</abstract><pub>IEEE</pub><doi>10.1109/TIA.2016.2614634</doi><tpages>13</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0093-9994
ispartof IEEE transactions on industry applications, 2017-01, Vol.53 (1), p.327-339
issn 0093-9994
1939-9367
language eng
recordid cdi_ieee_primary_7579626
source IEEE Xplore (Online service)
subjects Adjustable-speed drives (ASD)
Cable shielding
Clamps
common-mode (CM) current
Current measurement
double clamp methodology (DCM)
electromagnetic compatibility (EMC)
Impedance
Power cables
radiated electromagnetic interference (EMI)
Switched-mode power supply
switching converters
Variable speed drives
title Novel Double Clamp Methodology to Reduce Shielded Cable Radiated Emissions Initiated by Electronic Device Switching
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T18%3A16%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Novel%20Double%20Clamp%20Methodology%20to%20Reduce%20Shielded%20Cable%20Radiated%20Emissions%20Initiated%20by%20Electronic%20Device%20Switching&rft.jtitle=IEEE%20transactions%20on%20industry%20applications&rft.au=Vrankovic,%20Zoran&rft.date=2017-01&rft.volume=53&rft.issue=1&rft.spage=327&rft.epage=339&rft.pages=327-339&rft.issn=0093-9994&rft.eissn=1939-9367&rft.coden=ITIACR&rft_id=info:doi/10.1109/TIA.2016.2614634&rft_dat=%3Ccrossref_RIE%3E10_1109_TIA_2016_2614634%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=7579626&rfr_iscdi=true