On the Effects of Solar Panels on Distribution Transformers

Energy policies worldwide are mandating large-scale integration of solar panel (SP) generators with inverters on distribution systems. This causes several SPs to be connected to a distribution transformer. The SP and its interfacing inverter alter the performance characteristics of the transformer....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power delivery 2016-06, Vol.31 (3), p.1176-1185
Hauptverfasser: Awadallah, Mohamed A., Tianqi Xu, Venkatesh, Bala, Singh, Birendra N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1185
container_issue 3
container_start_page 1176
container_title IEEE transactions on power delivery
container_volume 31
creator Awadallah, Mohamed A.
Tianqi Xu
Venkatesh, Bala
Singh, Birendra N.
description Energy policies worldwide are mandating large-scale integration of solar panel (SP) generators with inverters on distribution systems. This causes several SPs to be connected to a distribution transformer. The SP and its interfacing inverter alter the performance characteristics of the transformer. In addition, when new sources and loads are connected to a distribution system, from an asset-management perspective, it is imperative to understand and quantify their effect on distribution system components. This paper presents a two-step study on the effects of SP on distribution transformers via simulation and experiments. In step one, the simulation work quantifies the amount of harmonic distortion caused by SP and associated inverters in distribution transformers considering solar farms and rooftop residential installations. The simulation work uses network topology, load, and generation data of a Canadian utility. Various inverter technologies, output powers, carrier signal frequencies, filtering techniques, numbers of active inverters, and transformer configurations are studied. In step two, level of harmonic distortion observed in simulation is created in a laboratory environment using a commercial inverter for SP applications. A three-phase dry-type transformer is tested to observe the effect of higher harmonic distortion on core and winding temperatures of the transformer. Experimental results conclude that under the worst case loading scenario (i.e., full load with active power flow reversed), the transformer lifetime expectancy is anticipated to decrease by 8.3%.
doi_str_mv 10.1109/TPWRD.2015.2443715
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_ieee_primary_7127048</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7127048</ieee_id><sourcerecordid>4065500971</sourcerecordid><originalsourceid>FETCH-LOGICAL-c328t-d84b17d4bb3c708281873b0f4bc4fc9ce821732f8f4931669b7a73db91dd3b2e3</originalsourceid><addsrcrecordid>eNpdkM9LwzAYhoMoOKf_gF4KXrx0fl-SNgmexM0fMNjQicfQpAl2dO1M2oP_vZ0bHjx9vPC8Hy8PIZcIE0RQt6vlx-t0QgGzCeWcCcyOyAgVEymnII_JCKTMUqmEOCVnMa4BgIOCEblbNEn36ZKZ9852MWl98tbWRUiWRePqITfJtIpdqEzfVUNYhaKJvg0bF-I5OfFFHd3F4Y7J--Ns9fCczhdPLw_389QyKru0lNygKLkxzAqQVKIUzIDnxnJvlXWSomDUS88VwzxXRhSClUZhWTJDHRuTm_3fbWi_ehc7vamidXU9TGz7qFFiDjkXFAb0-h-6bvvQDOs0CgW54jSjA0X3lA1tjMF5vQ3VpgjfGkHvfOpfn3rnUx98DqWrfalyzv0VBFIBXLIf3H9v3w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1790694252</pqid></control><display><type>article</type><title>On the Effects of Solar Panels on Distribution Transformers</title><source>IEEE Electronic Library (IEL)</source><creator>Awadallah, Mohamed A. ; Tianqi Xu ; Venkatesh, Bala ; Singh, Birendra N.</creator><creatorcontrib>Awadallah, Mohamed A. ; Tianqi Xu ; Venkatesh, Bala ; Singh, Birendra N.</creatorcontrib><description>Energy policies worldwide are mandating large-scale integration of solar panel (SP) generators with inverters on distribution systems. This causes several SPs to be connected to a distribution transformer. The SP and its interfacing inverter alter the performance characteristics of the transformer. In addition, when new sources and loads are connected to a distribution system, from an asset-management perspective, it is imperative to understand and quantify their effect on distribution system components. This paper presents a two-step study on the effects of SP on distribution transformers via simulation and experiments. In step one, the simulation work quantifies the amount of harmonic distortion caused by SP and associated inverters in distribution transformers considering solar farms and rooftop residential installations. The simulation work uses network topology, load, and generation data of a Canadian utility. Various inverter technologies, output powers, carrier signal frequencies, filtering techniques, numbers of active inverters, and transformer configurations are studied. In step two, level of harmonic distortion observed in simulation is created in a laboratory environment using a commercial inverter for SP applications. A three-phase dry-type transformer is tested to observe the effect of higher harmonic distortion on core and winding temperatures of the transformer. Experimental results conclude that under the worst case loading scenario (i.e., full load with active power flow reversed), the transformer lifetime expectancy is anticipated to decrease by 8.3%.</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/TPWRD.2015.2443715</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Cutoff frequency ; Distribution transformers ; Electric power ; Electricity distribution ; Filtering ; Harmonic analysis ; Harmonic distortion ; harmonics ; Inverters ; lifetime expectancy ; Panels ; Passive filters ; photovoltaic ; Power harmonic filters ; Simulation ; solar panels ; Solar power generation ; Stress concentration ; Transformers ; Windings</subject><ispartof>IEEE transactions on power delivery, 2016-06, Vol.31 (3), p.1176-1185</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c328t-d84b17d4bb3c708281873b0f4bc4fc9ce821732f8f4931669b7a73db91dd3b2e3</citedby><cites>FETCH-LOGICAL-c328t-d84b17d4bb3c708281873b0f4bc4fc9ce821732f8f4931669b7a73db91dd3b2e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7127048$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,778,782,794,27907,27908,54741</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/7127048$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Awadallah, Mohamed A.</creatorcontrib><creatorcontrib>Tianqi Xu</creatorcontrib><creatorcontrib>Venkatesh, Bala</creatorcontrib><creatorcontrib>Singh, Birendra N.</creatorcontrib><title>On the Effects of Solar Panels on Distribution Transformers</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>Energy policies worldwide are mandating large-scale integration of solar panel (SP) generators with inverters on distribution systems. This causes several SPs to be connected to a distribution transformer. The SP and its interfacing inverter alter the performance characteristics of the transformer. In addition, when new sources and loads are connected to a distribution system, from an asset-management perspective, it is imperative to understand and quantify their effect on distribution system components. This paper presents a two-step study on the effects of SP on distribution transformers via simulation and experiments. In step one, the simulation work quantifies the amount of harmonic distortion caused by SP and associated inverters in distribution transformers considering solar farms and rooftop residential installations. The simulation work uses network topology, load, and generation data of a Canadian utility. Various inverter technologies, output powers, carrier signal frequencies, filtering techniques, numbers of active inverters, and transformer configurations are studied. In step two, level of harmonic distortion observed in simulation is created in a laboratory environment using a commercial inverter for SP applications. A three-phase dry-type transformer is tested to observe the effect of higher harmonic distortion on core and winding temperatures of the transformer. Experimental results conclude that under the worst case loading scenario (i.e., full load with active power flow reversed), the transformer lifetime expectancy is anticipated to decrease by 8.3%.</description><subject>Cutoff frequency</subject><subject>Distribution transformers</subject><subject>Electric power</subject><subject>Electricity distribution</subject><subject>Filtering</subject><subject>Harmonic analysis</subject><subject>Harmonic distortion</subject><subject>harmonics</subject><subject>Inverters</subject><subject>lifetime expectancy</subject><subject>Panels</subject><subject>Passive filters</subject><subject>photovoltaic</subject><subject>Power harmonic filters</subject><subject>Simulation</subject><subject>solar panels</subject><subject>Solar power generation</subject><subject>Stress concentration</subject><subject>Transformers</subject><subject>Windings</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkM9LwzAYhoMoOKf_gF4KXrx0fl-SNgmexM0fMNjQicfQpAl2dO1M2oP_vZ0bHjx9vPC8Hy8PIZcIE0RQt6vlx-t0QgGzCeWcCcyOyAgVEymnII_JCKTMUqmEOCVnMa4BgIOCEblbNEn36ZKZ9852MWl98tbWRUiWRePqITfJtIpdqEzfVUNYhaKJvg0bF-I5OfFFHd3F4Y7J--Ns9fCczhdPLw_389QyKru0lNygKLkxzAqQVKIUzIDnxnJvlXWSomDUS88VwzxXRhSClUZhWTJDHRuTm_3fbWi_ehc7vamidXU9TGz7qFFiDjkXFAb0-h-6bvvQDOs0CgW54jSjA0X3lA1tjMF5vQ3VpgjfGkHvfOpfn3rnUx98DqWrfalyzv0VBFIBXLIf3H9v3w</recordid><startdate>20160601</startdate><enddate>20160601</enddate><creator>Awadallah, Mohamed A.</creator><creator>Tianqi Xu</creator><creator>Venkatesh, Bala</creator><creator>Singh, Birendra N.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><scope>F28</scope></search><sort><creationdate>20160601</creationdate><title>On the Effects of Solar Panels on Distribution Transformers</title><author>Awadallah, Mohamed A. ; Tianqi Xu ; Venkatesh, Bala ; Singh, Birendra N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c328t-d84b17d4bb3c708281873b0f4bc4fc9ce821732f8f4931669b7a73db91dd3b2e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Cutoff frequency</topic><topic>Distribution transformers</topic><topic>Electric power</topic><topic>Electricity distribution</topic><topic>Filtering</topic><topic>Harmonic analysis</topic><topic>Harmonic distortion</topic><topic>harmonics</topic><topic>Inverters</topic><topic>lifetime expectancy</topic><topic>Panels</topic><topic>Passive filters</topic><topic>photovoltaic</topic><topic>Power harmonic filters</topic><topic>Simulation</topic><topic>solar panels</topic><topic>Solar power generation</topic><topic>Stress concentration</topic><topic>Transformers</topic><topic>Windings</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Awadallah, Mohamed A.</creatorcontrib><creatorcontrib>Tianqi Xu</creatorcontrib><creatorcontrib>Venkatesh, Bala</creatorcontrib><creatorcontrib>Singh, Birendra N.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Awadallah, Mohamed A.</au><au>Tianqi Xu</au><au>Venkatesh, Bala</au><au>Singh, Birendra N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the Effects of Solar Panels on Distribution Transformers</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>2016-06-01</date><risdate>2016</risdate><volume>31</volume><issue>3</issue><spage>1176</spage><epage>1185</epage><pages>1176-1185</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>Energy policies worldwide are mandating large-scale integration of solar panel (SP) generators with inverters on distribution systems. This causes several SPs to be connected to a distribution transformer. The SP and its interfacing inverter alter the performance characteristics of the transformer. In addition, when new sources and loads are connected to a distribution system, from an asset-management perspective, it is imperative to understand and quantify their effect on distribution system components. This paper presents a two-step study on the effects of SP on distribution transformers via simulation and experiments. In step one, the simulation work quantifies the amount of harmonic distortion caused by SP and associated inverters in distribution transformers considering solar farms and rooftop residential installations. The simulation work uses network topology, load, and generation data of a Canadian utility. Various inverter technologies, output powers, carrier signal frequencies, filtering techniques, numbers of active inverters, and transformer configurations are studied. In step two, level of harmonic distortion observed in simulation is created in a laboratory environment using a commercial inverter for SP applications. A three-phase dry-type transformer is tested to observe the effect of higher harmonic distortion on core and winding temperatures of the transformer. Experimental results conclude that under the worst case loading scenario (i.e., full load with active power flow reversed), the transformer lifetime expectancy is anticipated to decrease by 8.3%.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TPWRD.2015.2443715</doi><tpages>10</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0885-8977
ispartof IEEE transactions on power delivery, 2016-06, Vol.31 (3), p.1176-1185
issn 0885-8977
1937-4208
language eng
recordid cdi_ieee_primary_7127048
source IEEE Electronic Library (IEL)
subjects Cutoff frequency
Distribution transformers
Electric power
Electricity distribution
Filtering
Harmonic analysis
Harmonic distortion
harmonics
Inverters
lifetime expectancy
Panels
Passive filters
photovoltaic
Power harmonic filters
Simulation
solar panels
Solar power generation
Stress concentration
Transformers
Windings
title On the Effects of Solar Panels on Distribution Transformers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T19%3A35%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20Effects%20of%20Solar%20Panels%20on%20Distribution%20Transformers&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Awadallah,%20Mohamed%20A.&rft.date=2016-06-01&rft.volume=31&rft.issue=3&rft.spage=1176&rft.epage=1185&rft.pages=1176-1185&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/TPWRD.2015.2443715&rft_dat=%3Cproquest_RIE%3E4065500971%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1790694252&rft_id=info:pmid/&rft_ieee_id=7127048&rfr_iscdi=true