POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns
Experimental results of microsecond plasma opening switch operation with four gas-puff plasma guns installed at the 1 TW GI-4 generator are given. The POS switching characteristics deteriorated for heavier gases. Stored current amplitude reached 1-1.2 MA and voltage ≲ 2 MV during switching on induct...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 188 |
---|---|
container_issue | |
container_start_page | 188 |
container_title | |
container_volume | |
creator | Ananjin, P.S. Hastrikov, A.N. Bugaev, S.P. Bystritskii, V.M. Grigoriev, S.U. Karpov, V.N. Kim, A.A. Kovalchuk, B.M. Kokshenev, V.N. Krasik, Y.E. Mesyats, G.A. Podkatov, V.I. Petrov, A.V. Sinebrjukhov, A.A. Usov, Y.P. Yakovlev, V.P. |
description | Experimental results of microsecond plasma opening switch operation with four gas-puff plasma guns installed at the 1 TW GI-4 generator are given. The POS switching characteristics deteriorated for heavier gases. Stored current amplitude reached 1-1.2 MA and voltage ≲ 2 MV during switching on inductive load of 200 nH with hydrogen puff plasma and 400 kV of output Marx voltage. The P0S translation length based on activation measurement along the axis made up 60 cm for 30 kA/cm of cathode linear density. The total number of high energy proton fraction in the P0S reached ˜ 0.5 MA with characteristic double hump ion flow density distribution and main maximum of 400 A/cm 2 at 30 cm distance from the gas-puff plasma guns. The analysis of diagnostic reliability and experimental results are given. The future experiments with P0S operating on diode load at GI-4 are discussed. |
doi_str_mv | 10.1109/PLASMA.1991.695725 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_695725</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>695725</ieee_id><sourcerecordid>695725</sourcerecordid><originalsourceid>FETCH-LOGICAL-i87t-e67a9ec8f03e31c01b78364a615f894749ddd68a5a6edb1f0e36e001a2ba676f3</originalsourceid><addsrcrecordid>eNotj11rgzAYhQNjsNH5B3qVP6DLazQfl1K6TrBYaO9LNG-6jFbF6D7-_YTucODcPTyHkDWwBIDp10NVHPdFAlpDInQu0_yBRFoqtpQzyGT2RKIQPtmSLAeW6meyP9RHuv0ZcPQ37KZA647ufTv2Adu-s7Ts7NxO_gtpmPoR6a6MM_rtpw96MSEeZufocDXhZuhl7sILeXTmGjD63xU5vW1Pm_e4qnflpqhir-QUo5BGY6sc48ihZdBIxUVmBORO6UVTW2uFMrkRaBtwDLlAxsCkjRFSOL4i6zvWI-J5WNTN-Hu-X-Z_PVZMVg</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ananjin, P.S. ; Hastrikov, A.N. ; Bugaev, S.P. ; Bystritskii, V.M. ; Grigoriev, S.U. ; Karpov, V.N. ; Kim, A.A. ; Kovalchuk, B.M. ; Kokshenev, V.N. ; Krasik, Y.E. ; Mesyats, G.A. ; Podkatov, V.I. ; Petrov, A.V. ; Sinebrjukhov, A.A. ; Usov, Y.P. ; Yakovlev, V.P.</creator><creatorcontrib>Ananjin, P.S. ; Hastrikov, A.N. ; Bugaev, S.P. ; Bystritskii, V.M. ; Grigoriev, S.U. ; Karpov, V.N. ; Kim, A.A. ; Kovalchuk, B.M. ; Kokshenev, V.N. ; Krasik, Y.E. ; Mesyats, G.A. ; Podkatov, V.I. ; Petrov, A.V. ; Sinebrjukhov, A.A. ; Usov, Y.P. ; Yakovlev, V.P.</creatorcontrib><description>Experimental results of microsecond plasma opening switch operation with four gas-puff plasma guns installed at the 1 TW GI-4 generator are given. The POS switching characteristics deteriorated for heavier gases. Stored current amplitude reached 1-1.2 MA and voltage ≲ 2 MV during switching on inductive load of 200 nH with hydrogen puff plasma and 400 kV of output Marx voltage. The P0S translation length based on activation measurement along the axis made up 60 cm for 30 kA/cm of cathode linear density. The total number of high energy proton fraction in the P0S reached ˜ 0.5 MA with characteristic double hump ion flow density distribution and main maximum of 400 A/cm 2 at 30 cm distance from the gas-puff plasma guns. The analysis of diagnostic reliability and experimental results are given. The future experiments with P0S operating on diode load at GI-4 are discussed.</description><identifier>ISBN: 9780780301474</identifier><identifier>ISBN: 0780301471</identifier><identifier>DOI: 10.1109/PLASMA.1991.695725</identifier><language>eng</language><publisher>IEEE</publisher><subject>Electron guns ; Nuclear electronics ; Nuclear physics ; Nuclear power generation ; Plasma density ; Plasma diagnostics ; Plasma measurements ; Plasma properties ; Switches ; Voltage</subject><ispartof>IEEE Conference Record - Abstracts. 1991 IEEE International Conference on Plasma Science, 1991, p.188-188</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/695725$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,4050,4051,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/695725$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ananjin, P.S.</creatorcontrib><creatorcontrib>Hastrikov, A.N.</creatorcontrib><creatorcontrib>Bugaev, S.P.</creatorcontrib><creatorcontrib>Bystritskii, V.M.</creatorcontrib><creatorcontrib>Grigoriev, S.U.</creatorcontrib><creatorcontrib>Karpov, V.N.</creatorcontrib><creatorcontrib>Kim, A.A.</creatorcontrib><creatorcontrib>Kovalchuk, B.M.</creatorcontrib><creatorcontrib>Kokshenev, V.N.</creatorcontrib><creatorcontrib>Krasik, Y.E.</creatorcontrib><creatorcontrib>Mesyats, G.A.</creatorcontrib><creatorcontrib>Podkatov, V.I.</creatorcontrib><creatorcontrib>Petrov, A.V.</creatorcontrib><creatorcontrib>Sinebrjukhov, A.A.</creatorcontrib><creatorcontrib>Usov, Y.P.</creatorcontrib><creatorcontrib>Yakovlev, V.P.</creatorcontrib><title>POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns</title><title>IEEE Conference Record - Abstracts. 1991 IEEE International Conference on Plasma Science</title><addtitle>PLASMA</addtitle><description>Experimental results of microsecond plasma opening switch operation with four gas-puff plasma guns installed at the 1 TW GI-4 generator are given. The POS switching characteristics deteriorated for heavier gases. Stored current amplitude reached 1-1.2 MA and voltage ≲ 2 MV during switching on inductive load of 200 nH with hydrogen puff plasma and 400 kV of output Marx voltage. The P0S translation length based on activation measurement along the axis made up 60 cm for 30 kA/cm of cathode linear density. The total number of high energy proton fraction in the P0S reached ˜ 0.5 MA with characteristic double hump ion flow density distribution and main maximum of 400 A/cm 2 at 30 cm distance from the gas-puff plasma guns. The analysis of diagnostic reliability and experimental results are given. The future experiments with P0S operating on diode load at GI-4 are discussed.</description><subject>Electron guns</subject><subject>Nuclear electronics</subject><subject>Nuclear physics</subject><subject>Nuclear power generation</subject><subject>Plasma density</subject><subject>Plasma diagnostics</subject><subject>Plasma measurements</subject><subject>Plasma properties</subject><subject>Switches</subject><subject>Voltage</subject><isbn>9780780301474</isbn><isbn>0780301471</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1991</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj11rgzAYhQNjsNH5B3qVP6DLazQfl1K6TrBYaO9LNG-6jFbF6D7-_YTucODcPTyHkDWwBIDp10NVHPdFAlpDInQu0_yBRFoqtpQzyGT2RKIQPtmSLAeW6meyP9RHuv0ZcPQ37KZA647ufTv2Adu-s7Ts7NxO_gtpmPoR6a6MM_rtpw96MSEeZufocDXhZuhl7sILeXTmGjD63xU5vW1Pm_e4qnflpqhir-QUo5BGY6sc48ihZdBIxUVmBORO6UVTW2uFMrkRaBtwDLlAxsCkjRFSOL4i6zvWI-J5WNTN-Hu-X-Z_PVZMVg</recordid><startdate>1991</startdate><enddate>1991</enddate><creator>Ananjin, P.S.</creator><creator>Hastrikov, A.N.</creator><creator>Bugaev, S.P.</creator><creator>Bystritskii, V.M.</creator><creator>Grigoriev, S.U.</creator><creator>Karpov, V.N.</creator><creator>Kim, A.A.</creator><creator>Kovalchuk, B.M.</creator><creator>Kokshenev, V.N.</creator><creator>Krasik, Y.E.</creator><creator>Mesyats, G.A.</creator><creator>Podkatov, V.I.</creator><creator>Petrov, A.V.</creator><creator>Sinebrjukhov, A.A.</creator><creator>Usov, Y.P.</creator><creator>Yakovlev, V.P.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1991</creationdate><title>POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns</title><author>Ananjin, P.S. ; Hastrikov, A.N. ; Bugaev, S.P. ; Bystritskii, V.M. ; Grigoriev, S.U. ; Karpov, V.N. ; Kim, A.A. ; Kovalchuk, B.M. ; Kokshenev, V.N. ; Krasik, Y.E. ; Mesyats, G.A. ; Podkatov, V.I. ; Petrov, A.V. ; Sinebrjukhov, A.A. ; Usov, Y.P. ; Yakovlev, V.P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i87t-e67a9ec8f03e31c01b78364a615f894749ddd68a5a6edb1f0e36e001a2ba676f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Electron guns</topic><topic>Nuclear electronics</topic><topic>Nuclear physics</topic><topic>Nuclear power generation</topic><topic>Plasma density</topic><topic>Plasma diagnostics</topic><topic>Plasma measurements</topic><topic>Plasma properties</topic><topic>Switches</topic><topic>Voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Ananjin, P.S.</creatorcontrib><creatorcontrib>Hastrikov, A.N.</creatorcontrib><creatorcontrib>Bugaev, S.P.</creatorcontrib><creatorcontrib>Bystritskii, V.M.</creatorcontrib><creatorcontrib>Grigoriev, S.U.</creatorcontrib><creatorcontrib>Karpov, V.N.</creatorcontrib><creatorcontrib>Kim, A.A.</creatorcontrib><creatorcontrib>Kovalchuk, B.M.</creatorcontrib><creatorcontrib>Kokshenev, V.N.</creatorcontrib><creatorcontrib>Krasik, Y.E.</creatorcontrib><creatorcontrib>Mesyats, G.A.</creatorcontrib><creatorcontrib>Podkatov, V.I.</creatorcontrib><creatorcontrib>Petrov, A.V.</creatorcontrib><creatorcontrib>Sinebrjukhov, A.A.</creatorcontrib><creatorcontrib>Usov, Y.P.</creatorcontrib><creatorcontrib>Yakovlev, V.P.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ananjin, P.S.</au><au>Hastrikov, A.N.</au><au>Bugaev, S.P.</au><au>Bystritskii, V.M.</au><au>Grigoriev, S.U.</au><au>Karpov, V.N.</au><au>Kim, A.A.</au><au>Kovalchuk, B.M.</au><au>Kokshenev, V.N.</au><au>Krasik, Y.E.</au><au>Mesyats, G.A.</au><au>Podkatov, V.I.</au><au>Petrov, A.V.</au><au>Sinebrjukhov, A.A.</au><au>Usov, Y.P.</au><au>Yakovlev, V.P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns</atitle><btitle>IEEE Conference Record - Abstracts. 1991 IEEE International Conference on Plasma Science</btitle><stitle>PLASMA</stitle><date>1991</date><risdate>1991</risdate><spage>188</spage><epage>188</epage><pages>188-188</pages><isbn>9780780301474</isbn><isbn>0780301471</isbn><abstract>Experimental results of microsecond plasma opening switch operation with four gas-puff plasma guns installed at the 1 TW GI-4 generator are given. The POS switching characteristics deteriorated for heavier gases. Stored current amplitude reached 1-1.2 MA and voltage ≲ 2 MV during switching on inductive load of 200 nH with hydrogen puff plasma and 400 kV of output Marx voltage. The P0S translation length based on activation measurement along the axis made up 60 cm for 30 kA/cm of cathode linear density. The total number of high energy proton fraction in the P0S reached ˜ 0.5 MA with characteristic double hump ion flow density distribution and main maximum of 400 A/cm 2 at 30 cm distance from the gas-puff plasma guns. The analysis of diagnostic reliability and experimental results are given. The future experiments with P0S operating on diode load at GI-4 are discussed.</abstract><pub>IEEE</pub><doi>10.1109/PLASMA.1991.695725</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9780780301474 |
ispartof | IEEE Conference Record - Abstracts. 1991 IEEE International Conference on Plasma Science, 1991, p.188-188 |
issn | |
language | eng |
recordid | cdi_ieee_primary_695725 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Electron guns Nuclear electronics Nuclear physics Nuclear power generation Plasma density Plasma diagnostics Plasma measurements Plasma properties Switches Voltage |
title | POS Experiments On Microsecond Inductive store GI-4 with gas-puff plasma guns |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A35%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=POS%20Experiments%20On%20Microsecond%20Inductive%20store%20GI-4%20with%20gas-puff%20plasma%20guns&rft.btitle=IEEE%20Conference%20Record%20-%20Abstracts.%201991%20IEEE%20International%20Conference%20on%20Plasma%20Science&rft.au=Ananjin,%20P.S.&rft.date=1991&rft.spage=188&rft.epage=188&rft.pages=188-188&rft.isbn=9780780301474&rft.isbn_list=0780301471&rft_id=info:doi/10.1109/PLASMA.1991.695725&rft_dat=%3Cieee_6IE%3E695725%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=695725&rfr_iscdi=true |