Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications

A new measurement of the anomalous magnetic moment (g-2) and electric dipole moment (EDM) of the positive muon at J-PARC is proposed, which measures the g-2 with the precision of 0.1 ppm and the EDM with sensitivity down to the order of 10 -21 e·cm. We proposed to use a highly-segmented positron tra...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ueno, K., Ikeda, H., Ikeno, M., Kohriki, T., Mibe, T., Nishimura, S., Uchida, T., Sasaki, O., Saito, N., Tanaka, M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6
container_issue
container_start_page 1
container_title
container_volume
creator Ueno, K.
Ikeda, H.
Ikeno, M.
Kohriki, T.
Mibe, T.
Nishimura, S.
Uchida, T.
Sasaki, O.
Saito, N.
Tanaka, M.
description A new measurement of the anomalous magnetic moment (g-2) and electric dipole moment (EDM) of the positive muon at J-PARC is proposed, which measures the g-2 with the precision of 0.1 ppm and the EDM with sensitivity down to the order of 10 -21 e·cm. We proposed to use a highly-segmented positron tracker in this experiment. From the simulation study, we chose a radial vane silicon strip detector as the tracker and have promoted the R&D. Then, the development of readout frontend ASIC is indispensible to achieve the detector goal performance. The ASIC requires good tracking efficiency due to the high hit rate of 1.6 MHz per strip, deep memory due to 5 muon life time (~40 μs) measurement, and high integration due to the large number of channels to the small space. We have developed the prototype ASIC with UMC 0.25μm CMOS technologies and evaluated that. In this paper, we report the design of the fast readout ASIC for the silicon-strip detector in the J-PARC muon g-2/EDM experiment and the performance of the prototype ASIC.
doi_str_mv 10.1109/NSSMIC.2013.6829771
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6829771</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6829771</ieee_id><sourcerecordid>6829771</sourcerecordid><originalsourceid>FETCH-LOGICAL-i208t-11f48b1aae1b358159209e2582b6ab3c0ac50e3285684b9b329c9188bdcf21813</originalsourceid><addsrcrecordid>eNotkNFKwzAYhaMoOOaeYDd5gWz5k6ZJLkfddLKpOL0eSftXI11bmgz07S3o1YFzDh-HQ8gc-AKA2-XT4bDfFgvBQS5yI6zWcEFmVhvItLVcycxckolQWjM-xldkAqMymavshsxi_OKcg9YiEzAhzcbFRAd0VXdOdHXYFrTuBhoDi2kIPa0wYZlGJ7Q0fSJ9ZC-r14Kezl1LP5hYru_2FL97HMIJ20RdW9Fu7A0jsnEJK-r6vgmlS6Fr4y25rl0TcfavU_K-Wb8VD2z3fL8tVjsWBDeJAdSZ8eAcgpfKgLKCWxTKCJ87L0vuSsVRCqNyk3nrpbClBWN8VdYCDMgpmf9xAyIe-3GbG36O_1_JX2huWlA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Ueno, K. ; Ikeda, H. ; Ikeno, M. ; Kohriki, T. ; Mibe, T. ; Nishimura, S. ; Uchida, T. ; Sasaki, O. ; Saito, N. ; Tanaka, M.</creator><creatorcontrib>Ueno, K. ; Ikeda, H. ; Ikeno, M. ; Kohriki, T. ; Mibe, T. ; Nishimura, S. ; Uchida, T. ; Sasaki, O. ; Saito, N. ; Tanaka, M.</creatorcontrib><description>A new measurement of the anomalous magnetic moment (g-2) and electric dipole moment (EDM) of the positive muon at J-PARC is proposed, which measures the g-2 with the precision of 0.1 ppm and the EDM with sensitivity down to the order of 10 -21 e·cm. We proposed to use a highly-segmented positron tracker in this experiment. From the simulation study, we chose a radial vane silicon strip detector as the tracker and have promoted the R&amp;D. Then, the development of readout frontend ASIC is indispensible to achieve the detector goal performance. The ASIC requires good tracking efficiency due to the high hit rate of 1.6 MHz per strip, deep memory due to 5 muon life time (~40 μs) measurement, and high integration due to the large number of channels to the small space. We have developed the prototype ASIC with UMC 0.25μm CMOS technologies and evaluated that. In this paper, we report the design of the fast readout ASIC for the silicon-strip detector in the J-PARC muon g-2/EDM experiment and the performance of the prototype ASIC.</description><identifier>ISSN: 1082-3654</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 9781479905348</identifier><identifier>EISBN: 9781479905331</identifier><identifier>EISBN: 1479905348</identifier><identifier>EISBN: 147990533X</identifier><identifier>DOI: 10.1109/NSSMIC.2013.6829771</identifier><language>eng</language><publisher>IEEE</publisher><subject>Application specific integrated circuits ; Blades ; Detectors ; Mesons ; Positrons ; Silicon ; Strips</subject><ispartof>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6829771$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6829771$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Ueno, K.</creatorcontrib><creatorcontrib>Ikeda, H.</creatorcontrib><creatorcontrib>Ikeno, M.</creatorcontrib><creatorcontrib>Kohriki, T.</creatorcontrib><creatorcontrib>Mibe, T.</creatorcontrib><creatorcontrib>Nishimura, S.</creatorcontrib><creatorcontrib>Uchida, T.</creatorcontrib><creatorcontrib>Sasaki, O.</creatorcontrib><creatorcontrib>Saito, N.</creatorcontrib><creatorcontrib>Tanaka, M.</creatorcontrib><title>Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications</title><title>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</title><addtitle>NSSMIC</addtitle><description>A new measurement of the anomalous magnetic moment (g-2) and electric dipole moment (EDM) of the positive muon at J-PARC is proposed, which measures the g-2 with the precision of 0.1 ppm and the EDM with sensitivity down to the order of 10 -21 e·cm. We proposed to use a highly-segmented positron tracker in this experiment. From the simulation study, we chose a radial vane silicon strip detector as the tracker and have promoted the R&amp;D. Then, the development of readout frontend ASIC is indispensible to achieve the detector goal performance. The ASIC requires good tracking efficiency due to the high hit rate of 1.6 MHz per strip, deep memory due to 5 muon life time (~40 μs) measurement, and high integration due to the large number of channels to the small space. We have developed the prototype ASIC with UMC 0.25μm CMOS technologies and evaluated that. In this paper, we report the design of the fast readout ASIC for the silicon-strip detector in the J-PARC muon g-2/EDM experiment and the performance of the prototype ASIC.</description><subject>Application specific integrated circuits</subject><subject>Blades</subject><subject>Detectors</subject><subject>Mesons</subject><subject>Positrons</subject><subject>Silicon</subject><subject>Strips</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>9781479905348</isbn><isbn>9781479905331</isbn><isbn>1479905348</isbn><isbn>147990533X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkNFKwzAYhaMoOOaeYDd5gWz5k6ZJLkfddLKpOL0eSftXI11bmgz07S3o1YFzDh-HQ8gc-AKA2-XT4bDfFgvBQS5yI6zWcEFmVhvItLVcycxckolQWjM-xldkAqMymavshsxi_OKcg9YiEzAhzcbFRAd0VXdOdHXYFrTuBhoDi2kIPa0wYZlGJ7Q0fSJ9ZC-r14Kezl1LP5hYru_2FL97HMIJ20RdW9Fu7A0jsnEJK-r6vgmlS6Fr4y25rl0TcfavU_K-Wb8VD2z3fL8tVjsWBDeJAdSZ8eAcgpfKgLKCWxTKCJ87L0vuSsVRCqNyk3nrpbClBWN8VdYCDMgpmf9xAyIe-3GbG36O_1_JX2huWlA</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Ueno, K.</creator><creator>Ikeda, H.</creator><creator>Ikeno, M.</creator><creator>Kohriki, T.</creator><creator>Mibe, T.</creator><creator>Nishimura, S.</creator><creator>Uchida, T.</creator><creator>Sasaki, O.</creator><creator>Saito, N.</creator><creator>Tanaka, M.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20131001</creationdate><title>Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications</title><author>Ueno, K. ; Ikeda, H. ; Ikeno, M. ; Kohriki, T. ; Mibe, T. ; Nishimura, S. ; Uchida, T. ; Sasaki, O. ; Saito, N. ; Tanaka, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i208t-11f48b1aae1b358159209e2582b6ab3c0ac50e3285684b9b329c9188bdcf21813</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Application specific integrated circuits</topic><topic>Blades</topic><topic>Detectors</topic><topic>Mesons</topic><topic>Positrons</topic><topic>Silicon</topic><topic>Strips</topic><toplevel>online_resources</toplevel><creatorcontrib>Ueno, K.</creatorcontrib><creatorcontrib>Ikeda, H.</creatorcontrib><creatorcontrib>Ikeno, M.</creatorcontrib><creatorcontrib>Kohriki, T.</creatorcontrib><creatorcontrib>Mibe, T.</creatorcontrib><creatorcontrib>Nishimura, S.</creatorcontrib><creatorcontrib>Uchida, T.</creatorcontrib><creatorcontrib>Sasaki, O.</creatorcontrib><creatorcontrib>Saito, N.</creatorcontrib><creatorcontrib>Tanaka, M.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ueno, K.</au><au>Ikeda, H.</au><au>Ikeno, M.</au><au>Kohriki, T.</au><au>Mibe, T.</au><au>Nishimura, S.</au><au>Uchida, T.</au><au>Sasaki, O.</au><au>Saito, N.</au><au>Tanaka, M.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications</atitle><btitle>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</btitle><stitle>NSSMIC</stitle><date>2013-10-01</date><risdate>2013</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><eisbn>9781479905348</eisbn><eisbn>9781479905331</eisbn><eisbn>1479905348</eisbn><eisbn>147990533X</eisbn><abstract>A new measurement of the anomalous magnetic moment (g-2) and electric dipole moment (EDM) of the positive muon at J-PARC is proposed, which measures the g-2 with the precision of 0.1 ppm and the EDM with sensitivity down to the order of 10 -21 e·cm. We proposed to use a highly-segmented positron tracker in this experiment. From the simulation study, we chose a radial vane silicon strip detector as the tracker and have promoted the R&amp;D. Then, the development of readout frontend ASIC is indispensible to achieve the detector goal performance. The ASIC requires good tracking efficiency due to the high hit rate of 1.6 MHz per strip, deep memory due to 5 muon life time (~40 μs) measurement, and high integration due to the large number of channels to the small space. We have developed the prototype ASIC with UMC 0.25μm CMOS technologies and evaluated that. In this paper, we report the design of the fast readout ASIC for the silicon-strip detector in the J-PARC muon g-2/EDM experiment and the performance of the prototype ASIC.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2013.6829771</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-6
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6829771
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Application specific integrated circuits
Blades
Detectors
Mesons
Positrons
Silicon
Strips
title Fast readout ASIC for si-strip detector in the J-PARC muon g-2/EDM experiment and other related applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T22%3A18%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Fast%20readout%20ASIC%20for%20si-strip%20detector%20in%20the%20J-PARC%20muon%20g-2/EDM%20experiment%20and%20other%20related%20applications&rft.btitle=2013%20IEEE%20Nuclear%20Science%20Symposium%20and%20Medical%20Imaging%20Conference%20(2013%20NSS/MIC)&rft.au=Ueno,%20K.&rft.date=2013-10-01&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=1082-3654&rft.eissn=2577-0829&rft_id=info:doi/10.1109/NSSMIC.2013.6829771&rft_dat=%3Cieee_6IE%3E6829771%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781479905348&rft.eisbn_list=9781479905331&rft.eisbn_list=1479905348&rft.eisbn_list=147990533X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6829771&rfr_iscdi=true