Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals

The goal of this conference record is to present the experiments conducted to evaluate a magnetic resonance (MR) compatible, simultaneous SPECT-MR insert for small animal (SA) imaging that we have been working on for the last three years. As previously demonstrated, the insert consists of 5 rings of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rittenbach, A., Xu, J., El-Sharkawy, A. M., Edelstein, W. A., Parnham, K., Hugg, J., Tsui, B. M. W.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5
container_issue
container_start_page 1
container_title
container_volume
creator Rittenbach, A.
Xu, J.
El-Sharkawy, A. M.
Edelstein, W. A.
Parnham, K.
Hugg, J.
Tsui, B. M. W.
description The goal of this conference record is to present the experiments conducted to evaluate a magnetic resonance (MR) compatible, simultaneous SPECT-MR insert for small animal (SA) imaging that we have been working on for the last three years. As previously demonstrated, the insert consists of 5 rings of 19 MR compatible CZT detectors connected seamlessly. A multi-pinhole (MPH) collimator with focused pinholes was built using a plastic shell filled with high-density coated tungsten powder and fitted with solid tungsten pinhole inserts. To acquire SPECT and MR data simultaneously, a shielded transmit/receive radio frequency (RF) coil is inserted into the MPH collimator. The insert was evaluated as a standalone SA SPECT system using both a hot-rod resolution phantom (HR-RP) experiment and SA imaging studies. Furthermore, simultaneous SPECT-MR phantom and SA imaging experiments were conducted by placing the SPECT-MR insert inside a 3T clinical MRI system. From acquired experimental data, SPECT images were reconstructed using an in-house developed 3D MPH ML-EM method with pinhole collimator detector response model and compensation. As a standalone SA SPECT system, the insert provided good quality images in phantom and SA studies. The quality of the SPECT images of the HR-RP acquired during the simultaneous SPECT-MR imaging experiment was comparable to the quality of the images acquired during standalone SPECT acquisition. Despite the fact that the SPECT insert degraded the MR image signal-to-noise-ratio (SNR) and caused field distortions, MR imaging was possible within the specific field-of-view of interest. When registered and fused, the SPECT and MR HR-RP images were found to be in acceptable geometric agreement. Data acquired during the simultaneous SPECT-MR SA study was used to obtain a dynamic SPECT image and Time Activity Curve showing initial uptake and later washout of 99 mTc MAG3 into and out of a mouse's kidneys. Furthermore, a SPECT kidney image was fused with the simultaneously acquired MR image and showed acceptable geometric agreement. Fast dynamic MR imaging was not possible due to severe geometric distortions present when using high speed sequences. These experimental results demonstrate the ability of the insert to obtain SA SPECT dynamic studies and the feasibility of simultaneous SA SPECT-MR imaging. Further engineering improvements remain to be explored to reduce the interaction between the SPECT and MR systems and to eventually enable simultane
doi_str_mv 10.1109/NSSMIC.2013.6829143
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6829143</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6829143</ieee_id><sourcerecordid>6829143</sourcerecordid><originalsourceid>FETCH-LOGICAL-i208t-3e42081e65c78182434d1e7d9c4f6e6e3aac329490b2b197e954d8b118f044e63</originalsourceid><addsrcrecordid>eNotkNFKwzAUhqMoWOaeYDd5gc6cJG2SSylTB5uKm9cjbU9HpE1H0wq-vRnb1Qf_z_kO5xCyALYEYObpfbfbroslZyCWueYGpLghc6M0SGUMy4TUtyThmVIpi_UdSSAyFXkmH8g8hB_GGCjFJYeEuKL3o_OT80eKv7ad7Oh6T_uGWk-3X7Tqu1OMyhbp7nNV7KnzAYeRNv1Ag-umdrQe-ylc2jROuM4ez7aoCJ1t2yiKURseyX0TgfMrZ-T7ZbUv3tLNx-u6eN6kjjM9pgJlJGCeVfEizaWQNaCqTSWbHHMU1laCG2lYyUswCk0ma10C6IZJibmYkcXF6xDxcBri8uHvcH2U-AcMj1oG</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Rittenbach, A. ; Xu, J. ; El-Sharkawy, A. M. ; Edelstein, W. A. ; Parnham, K. ; Hugg, J. ; Tsui, B. M. W.</creator><creatorcontrib>Rittenbach, A. ; Xu, J. ; El-Sharkawy, A. M. ; Edelstein, W. A. ; Parnham, K. ; Hugg, J. ; Tsui, B. M. W.</creatorcontrib><description>The goal of this conference record is to present the experiments conducted to evaluate a magnetic resonance (MR) compatible, simultaneous SPECT-MR insert for small animal (SA) imaging that we have been working on for the last three years. As previously demonstrated, the insert consists of 5 rings of 19 MR compatible CZT detectors connected seamlessly. A multi-pinhole (MPH) collimator with focused pinholes was built using a plastic shell filled with high-density coated tungsten powder and fitted with solid tungsten pinhole inserts. To acquire SPECT and MR data simultaneously, a shielded transmit/receive radio frequency (RF) coil is inserted into the MPH collimator. The insert was evaluated as a standalone SA SPECT system using both a hot-rod resolution phantom (HR-RP) experiment and SA imaging studies. Furthermore, simultaneous SPECT-MR phantom and SA imaging experiments were conducted by placing the SPECT-MR insert inside a 3T clinical MRI system. From acquired experimental data, SPECT images were reconstructed using an in-house developed 3D MPH ML-EM method with pinhole collimator detector response model and compensation. As a standalone SA SPECT system, the insert provided good quality images in phantom and SA studies. The quality of the SPECT images of the HR-RP acquired during the simultaneous SPECT-MR imaging experiment was comparable to the quality of the images acquired during standalone SPECT acquisition. Despite the fact that the SPECT insert degraded the MR image signal-to-noise-ratio (SNR) and caused field distortions, MR imaging was possible within the specific field-of-view of interest. When registered and fused, the SPECT and MR HR-RP images were found to be in acceptable geometric agreement. Data acquired during the simultaneous SPECT-MR SA study was used to obtain a dynamic SPECT image and Time Activity Curve showing initial uptake and later washout of 99 mTc MAG3 into and out of a mouse's kidneys. Furthermore, a SPECT kidney image was fused with the simultaneously acquired MR image and showed acceptable geometric agreement. Fast dynamic MR imaging was not possible due to severe geometric distortions present when using high speed sequences. These experimental results demonstrate the ability of the insert to obtain SA SPECT dynamic studies and the feasibility of simultaneous SA SPECT-MR imaging. Further engineering improvements remain to be explored to reduce the interaction between the SPECT and MR systems and to eventually enable simultaneous fast dynamic MR studies over the full volume of subject animals.</description><identifier>ISSN: 1082-3654</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 9781479905348</identifier><identifier>EISBN: 9781479905331</identifier><identifier>EISBN: 1479905348</identifier><identifier>EISBN: 147990533X</identifier><identifier>DOI: 10.1109/NSSMIC.2013.6829143</identifier><language>eng</language><publisher>IEEE</publisher><subject>Collimators ; Image reconstruction ; Imaging phantoms ; Kidney ; Phantoms ; Single photon emission computed tomography</subject><ispartof>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6829143$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6829143$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Rittenbach, A.</creatorcontrib><creatorcontrib>Xu, J.</creatorcontrib><creatorcontrib>El-Sharkawy, A. M.</creatorcontrib><creatorcontrib>Edelstein, W. A.</creatorcontrib><creatorcontrib>Parnham, K.</creatorcontrib><creatorcontrib>Hugg, J.</creatorcontrib><creatorcontrib>Tsui, B. M. W.</creatorcontrib><title>Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals</title><title>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</title><addtitle>NSSMIC</addtitle><description>The goal of this conference record is to present the experiments conducted to evaluate a magnetic resonance (MR) compatible, simultaneous SPECT-MR insert for small animal (SA) imaging that we have been working on for the last three years. As previously demonstrated, the insert consists of 5 rings of 19 MR compatible CZT detectors connected seamlessly. A multi-pinhole (MPH) collimator with focused pinholes was built using a plastic shell filled with high-density coated tungsten powder and fitted with solid tungsten pinhole inserts. To acquire SPECT and MR data simultaneously, a shielded transmit/receive radio frequency (RF) coil is inserted into the MPH collimator. The insert was evaluated as a standalone SA SPECT system using both a hot-rod resolution phantom (HR-RP) experiment and SA imaging studies. Furthermore, simultaneous SPECT-MR phantom and SA imaging experiments were conducted by placing the SPECT-MR insert inside a 3T clinical MRI system. From acquired experimental data, SPECT images were reconstructed using an in-house developed 3D MPH ML-EM method with pinhole collimator detector response model and compensation. As a standalone SA SPECT system, the insert provided good quality images in phantom and SA studies. The quality of the SPECT images of the HR-RP acquired during the simultaneous SPECT-MR imaging experiment was comparable to the quality of the images acquired during standalone SPECT acquisition. Despite the fact that the SPECT insert degraded the MR image signal-to-noise-ratio (SNR) and caused field distortions, MR imaging was possible within the specific field-of-view of interest. When registered and fused, the SPECT and MR HR-RP images were found to be in acceptable geometric agreement. Data acquired during the simultaneous SPECT-MR SA study was used to obtain a dynamic SPECT image and Time Activity Curve showing initial uptake and later washout of 99 mTc MAG3 into and out of a mouse's kidneys. Furthermore, a SPECT kidney image was fused with the simultaneously acquired MR image and showed acceptable geometric agreement. Fast dynamic MR imaging was not possible due to severe geometric distortions present when using high speed sequences. These experimental results demonstrate the ability of the insert to obtain SA SPECT dynamic studies and the feasibility of simultaneous SA SPECT-MR imaging. Further engineering improvements remain to be explored to reduce the interaction between the SPECT and MR systems and to eventually enable simultaneous fast dynamic MR studies over the full volume of subject animals.</description><subject>Collimators</subject><subject>Image reconstruction</subject><subject>Imaging phantoms</subject><subject>Kidney</subject><subject>Phantoms</subject><subject>Single photon emission computed tomography</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>9781479905348</isbn><isbn>9781479905331</isbn><isbn>1479905348</isbn><isbn>147990533X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkNFKwzAUhqMoWOaeYDd5gc6cJG2SSylTB5uKm9cjbU9HpE1H0wq-vRnb1Qf_z_kO5xCyALYEYObpfbfbroslZyCWueYGpLghc6M0SGUMy4TUtyThmVIpi_UdSSAyFXkmH8g8hB_GGCjFJYeEuKL3o_OT80eKv7ad7Oh6T_uGWk-3X7Tqu1OMyhbp7nNV7KnzAYeRNv1Ag-umdrQe-ylc2jROuM4ez7aoCJ1t2yiKURseyX0TgfMrZ-T7ZbUv3tLNx-u6eN6kjjM9pgJlJGCeVfEizaWQNaCqTSWbHHMU1laCG2lYyUswCk0ma10C6IZJibmYkcXF6xDxcBri8uHvcH2U-AcMj1oG</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Rittenbach, A.</creator><creator>Xu, J.</creator><creator>El-Sharkawy, A. M.</creator><creator>Edelstein, W. A.</creator><creator>Parnham, K.</creator><creator>Hugg, J.</creator><creator>Tsui, B. M. W.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>20131001</creationdate><title>Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals</title><author>Rittenbach, A. ; Xu, J. ; El-Sharkawy, A. M. ; Edelstein, W. A. ; Parnham, K. ; Hugg, J. ; Tsui, B. M. W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i208t-3e42081e65c78182434d1e7d9c4f6e6e3aac329490b2b197e954d8b118f044e63</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Collimators</topic><topic>Image reconstruction</topic><topic>Imaging phantoms</topic><topic>Kidney</topic><topic>Phantoms</topic><topic>Single photon emission computed tomography</topic><toplevel>online_resources</toplevel><creatorcontrib>Rittenbach, A.</creatorcontrib><creatorcontrib>Xu, J.</creatorcontrib><creatorcontrib>El-Sharkawy, A. M.</creatorcontrib><creatorcontrib>Edelstein, W. A.</creatorcontrib><creatorcontrib>Parnham, K.</creatorcontrib><creatorcontrib>Hugg, J.</creatorcontrib><creatorcontrib>Tsui, B. M. W.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Rittenbach, A.</au><au>Xu, J.</au><au>El-Sharkawy, A. M.</au><au>Edelstein, W. A.</au><au>Parnham, K.</au><au>Hugg, J.</au><au>Tsui, B. M. W.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals</atitle><btitle>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</btitle><stitle>NSSMIC</stitle><date>2013-10-01</date><risdate>2013</risdate><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><eisbn>9781479905348</eisbn><eisbn>9781479905331</eisbn><eisbn>1479905348</eisbn><eisbn>147990533X</eisbn><abstract>The goal of this conference record is to present the experiments conducted to evaluate a magnetic resonance (MR) compatible, simultaneous SPECT-MR insert for small animal (SA) imaging that we have been working on for the last three years. As previously demonstrated, the insert consists of 5 rings of 19 MR compatible CZT detectors connected seamlessly. A multi-pinhole (MPH) collimator with focused pinholes was built using a plastic shell filled with high-density coated tungsten powder and fitted with solid tungsten pinhole inserts. To acquire SPECT and MR data simultaneously, a shielded transmit/receive radio frequency (RF) coil is inserted into the MPH collimator. The insert was evaluated as a standalone SA SPECT system using both a hot-rod resolution phantom (HR-RP) experiment and SA imaging studies. Furthermore, simultaneous SPECT-MR phantom and SA imaging experiments were conducted by placing the SPECT-MR insert inside a 3T clinical MRI system. From acquired experimental data, SPECT images were reconstructed using an in-house developed 3D MPH ML-EM method with pinhole collimator detector response model and compensation. As a standalone SA SPECT system, the insert provided good quality images in phantom and SA studies. The quality of the SPECT images of the HR-RP acquired during the simultaneous SPECT-MR imaging experiment was comparable to the quality of the images acquired during standalone SPECT acquisition. Despite the fact that the SPECT insert degraded the MR image signal-to-noise-ratio (SNR) and caused field distortions, MR imaging was possible within the specific field-of-view of interest. When registered and fused, the SPECT and MR HR-RP images were found to be in acceptable geometric agreement. Data acquired during the simultaneous SPECT-MR SA study was used to obtain a dynamic SPECT image and Time Activity Curve showing initial uptake and later washout of 99 mTc MAG3 into and out of a mouse's kidneys. Furthermore, a SPECT kidney image was fused with the simultaneously acquired MR image and showed acceptable geometric agreement. Fast dynamic MR imaging was not possible due to severe geometric distortions present when using high speed sequences. These experimental results demonstrate the ability of the insert to obtain SA SPECT dynamic studies and the feasibility of simultaneous SA SPECT-MR imaging. Further engineering improvements remain to be explored to reduce the interaction between the SPECT and MR systems and to eventually enable simultaneous fast dynamic MR studies over the full volume of subject animals.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2013.6829143</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-5
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6829143
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Collimators
Image reconstruction
Imaging phantoms
Kidney
Phantoms
Single photon emission computed tomography
title Continuing evaluation of an MR compatible SPECT insert for simultaneous SPECT-MR imaging of small animals
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T12%3A50%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Continuing%20evaluation%20of%20an%20MR%20compatible%20SPECT%20insert%20for%20simultaneous%20SPECT-MR%20imaging%20of%20small%20animals&rft.btitle=2013%20IEEE%20Nuclear%20Science%20Symposium%20and%20Medical%20Imaging%20Conference%20(2013%20NSS/MIC)&rft.au=Rittenbach,%20A.&rft.date=2013-10-01&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=1082-3654&rft.eissn=2577-0829&rft_id=info:doi/10.1109/NSSMIC.2013.6829143&rft_dat=%3Cieee_6IE%3E6829143%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781479905348&rft.eisbn_list=9781479905331&rft.eisbn_list=1479905348&rft.eisbn_list=147990533X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6829143&rfr_iscdi=true