A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source

Several MRI-based attenuation correction methods have been reported for PET/MRI. The accuracy of the attenuation map (μ-map) from an MRI image depends on correctness of the segmentation of tissue and the attenuation coefficients to be assigned (μ-values). However, an MRI image does not reflect the a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kawaguchi, Hiroshi, Hirano, Yoshiyuki, Yoshida, Eiji, Suga, Mikio, Shiraishi, Takahiro, Tanimoto, Katsuyuki, Kimura, Yasuyuki, Obata, Takayuki, Ito, Hiroshi, Yamaya, Taiga
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2
container_issue
container_start_page 1
container_title
container_volume
creator Kawaguchi, Hiroshi
Hirano, Yoshiyuki
Yoshida, Eiji
Suga, Mikio
Shiraishi, Takahiro
Tanimoto, Katsuyuki
Kimura, Yasuyuki
Obata, Takayuki
Ito, Hiroshi
Yamaya, Taiga
description Several MRI-based attenuation correction methods have been reported for PET/MRI. The accuracy of the attenuation map (μ-map) from an MRI image depends on correctness of the segmentation of tissue and the attenuation coefficients to be assigned (μ-values). However, an MRI image does not reflect the attenuation of radiation and inaccurate assignment of μ-values affects the quantitative assessment of functional images of PET. Although installation of a transmission scan function on the PET/MRI can provide an accurate μ-map, it restricts the design of the scanner, increases the manufacturing cost and takes additional scanning time. In this study, we implemented an MRI-based μ-value estimation method with a non-rotational radiation source to construct the proper μ-map for PET/MRI and assessed it based on clinical data sets. The proposed method uses the accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position radiation source which usually rotates around the subject to obtain the μ-map with the tomographic procedure. According to the Lambert-Beer law, attenuated intensity is described as the function of partial path length and μ-values of every tissue. The partial path length could be estimated by the simulation of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue could be estimated by inverting the function. The simulation results, based upon measurement data, showed the errors between μ-values of the conventional transmission scan and our proposed method were 2.3±0.9%, 18.6±8.0% and -11.1±5.5% for brain, bone and soft tissue other than brain, respectively. Although there were over- and under-estimations for bone and soft tissue, respectively, the present method is able to estimate the brain μ-value accurately in clinical situations and that strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain.
doi_str_mv 10.1109/NSSMIC.2013.6829141
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6829141</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6829141</ieee_id><sourcerecordid>6829141</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-e8f215e94362ae2448ee6122f14651d16afa4cd7a60cf9c317815e063211b6fb3</originalsourceid><addsrcrecordid>eNotUF1OAjEYrEYTCXICXnqBYr-2224fCUElATWCz6Tb_RprgCXbXZW7cQbP5AZ4mknmJ5khZAh8BMDtw8tyuZhNRoKDHOlcWFBwRQbW5KCMtTyTKr8mPZEZw3gn35AedMikztQdGaT0xTkHY4QS0CN-TBfvM1a4hCV9m66oaxrcta6J1Y76qq7Rn-hPbD7p35F9u02LiW7RpbbuIsWBOhriL5ZsX6V48taujOeCVLW1x3tyG9wm4eCCffLxOF1Nntn89Wk2Gc9ZBJM1DPMgIEOrpBYOhVI5ogYhAiidQQnaBad8aZzmPlgvoVucIddSABQ6FLJPhufeiIjrfR23rj6sLxfJf3aBWYM</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Kawaguchi, Hiroshi ; Hirano, Yoshiyuki ; Yoshida, Eiji ; Suga, Mikio ; Shiraishi, Takahiro ; Tanimoto, Katsuyuki ; Kimura, Yasuyuki ; Obata, Takayuki ; Ito, Hiroshi ; Yamaya, Taiga</creator><creatorcontrib>Kawaguchi, Hiroshi ; Hirano, Yoshiyuki ; Yoshida, Eiji ; Suga, Mikio ; Shiraishi, Takahiro ; Tanimoto, Katsuyuki ; Kimura, Yasuyuki ; Obata, Takayuki ; Ito, Hiroshi ; Yamaya, Taiga</creatorcontrib><description>Several MRI-based attenuation correction methods have been reported for PET/MRI. The accuracy of the attenuation map (μ-map) from an MRI image depends on correctness of the segmentation of tissue and the attenuation coefficients to be assigned (μ-values). However, an MRI image does not reflect the attenuation of radiation and inaccurate assignment of μ-values affects the quantitative assessment of functional images of PET. Although installation of a transmission scan function on the PET/MRI can provide an accurate μ-map, it restricts the design of the scanner, increases the manufacturing cost and takes additional scanning time. In this study, we implemented an MRI-based μ-value estimation method with a non-rotational radiation source to construct the proper μ-map for PET/MRI and assessed it based on clinical data sets. The proposed method uses the accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position radiation source which usually rotates around the subject to obtain the μ-map with the tomographic procedure. According to the Lambert-Beer law, attenuated intensity is described as the function of partial path length and μ-values of every tissue. The partial path length could be estimated by the simulation of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue could be estimated by inverting the function. The simulation results, based upon measurement data, showed the errors between μ-values of the conventional transmission scan and our proposed method were 2.3±0.9%, 18.6±8.0% and -11.1±5.5% for brain, bone and soft tissue other than brain, respectively. Although there were over- and under-estimations for bone and soft tissue, respectively, the present method is able to estimate the brain μ-value accurately in clinical situations and that strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain.</description><identifier>ISSN: 1082-3654</identifier><identifier>EISSN: 2577-0829</identifier><identifier>EISBN: 9781479905348</identifier><identifier>EISBN: 9781479905331</identifier><identifier>EISBN: 1479905348</identifier><identifier>EISBN: 147990533X</identifier><identifier>DOI: 10.1109/NSSMIC.2013.6829141</identifier><language>eng</language><publisher>IEEE</publisher><subject>Attenuation ; Biological tissues ; Bones ; Detectors ; Image segmentation ; Magnetic resonance imaging ; Positron emission tomography</subject><ispartof>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-2</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6829141$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,778,782,787,788,2054,27912,54907</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6829141$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kawaguchi, Hiroshi</creatorcontrib><creatorcontrib>Hirano, Yoshiyuki</creatorcontrib><creatorcontrib>Yoshida, Eiji</creatorcontrib><creatorcontrib>Suga, Mikio</creatorcontrib><creatorcontrib>Shiraishi, Takahiro</creatorcontrib><creatorcontrib>Tanimoto, Katsuyuki</creatorcontrib><creatorcontrib>Kimura, Yasuyuki</creatorcontrib><creatorcontrib>Obata, Takayuki</creatorcontrib><creatorcontrib>Ito, Hiroshi</creatorcontrib><creatorcontrib>Yamaya, Taiga</creatorcontrib><title>A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source</title><title>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</title><addtitle>NSSMIC</addtitle><description>Several MRI-based attenuation correction methods have been reported for PET/MRI. The accuracy of the attenuation map (μ-map) from an MRI image depends on correctness of the segmentation of tissue and the attenuation coefficients to be assigned (μ-values). However, an MRI image does not reflect the attenuation of radiation and inaccurate assignment of μ-values affects the quantitative assessment of functional images of PET. Although installation of a transmission scan function on the PET/MRI can provide an accurate μ-map, it restricts the design of the scanner, increases the manufacturing cost and takes additional scanning time. In this study, we implemented an MRI-based μ-value estimation method with a non-rotational radiation source to construct the proper μ-map for PET/MRI and assessed it based on clinical data sets. The proposed method uses the accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position radiation source which usually rotates around the subject to obtain the μ-map with the tomographic procedure. According to the Lambert-Beer law, attenuated intensity is described as the function of partial path length and μ-values of every tissue. The partial path length could be estimated by the simulation of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue could be estimated by inverting the function. The simulation results, based upon measurement data, showed the errors between μ-values of the conventional transmission scan and our proposed method were 2.3±0.9%, 18.6±8.0% and -11.1±5.5% for brain, bone and soft tissue other than brain, respectively. Although there were over- and under-estimations for bone and soft tissue, respectively, the present method is able to estimate the brain μ-value accurately in clinical situations and that strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain.</description><subject>Attenuation</subject><subject>Biological tissues</subject><subject>Bones</subject><subject>Detectors</subject><subject>Image segmentation</subject><subject>Magnetic resonance imaging</subject><subject>Positron emission tomography</subject><issn>1082-3654</issn><issn>2577-0829</issn><isbn>9781479905348</isbn><isbn>9781479905331</isbn><isbn>1479905348</isbn><isbn>147990533X</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotUF1OAjEYrEYTCXICXnqBYr-2224fCUElATWCz6Tb_RprgCXbXZW7cQbP5AZ4mknmJ5khZAh8BMDtw8tyuZhNRoKDHOlcWFBwRQbW5KCMtTyTKr8mPZEZw3gn35AedMikztQdGaT0xTkHY4QS0CN-TBfvM1a4hCV9m66oaxrcta6J1Y76qq7Rn-hPbD7p35F9u02LiW7RpbbuIsWBOhriL5ZsX6V48taujOeCVLW1x3tyG9wm4eCCffLxOF1Nntn89Wk2Gc9ZBJM1DPMgIEOrpBYOhVI5ogYhAiidQQnaBad8aZzmPlgvoVucIddSABQ6FLJPhufeiIjrfR23rj6sLxfJf3aBWYM</recordid><startdate>201310</startdate><enddate>201310</enddate><creator>Kawaguchi, Hiroshi</creator><creator>Hirano, Yoshiyuki</creator><creator>Yoshida, Eiji</creator><creator>Suga, Mikio</creator><creator>Shiraishi, Takahiro</creator><creator>Tanimoto, Katsuyuki</creator><creator>Kimura, Yasuyuki</creator><creator>Obata, Takayuki</creator><creator>Ito, Hiroshi</creator><creator>Yamaya, Taiga</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201310</creationdate><title>A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source</title><author>Kawaguchi, Hiroshi ; Hirano, Yoshiyuki ; Yoshida, Eiji ; Suga, Mikio ; Shiraishi, Takahiro ; Tanimoto, Katsuyuki ; Kimura, Yasuyuki ; Obata, Takayuki ; Ito, Hiroshi ; Yamaya, Taiga</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-e8f215e94362ae2448ee6122f14651d16afa4cd7a60cf9c317815e063211b6fb3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Attenuation</topic><topic>Biological tissues</topic><topic>Bones</topic><topic>Detectors</topic><topic>Image segmentation</topic><topic>Magnetic resonance imaging</topic><topic>Positron emission tomography</topic><toplevel>online_resources</toplevel><creatorcontrib>Kawaguchi, Hiroshi</creatorcontrib><creatorcontrib>Hirano, Yoshiyuki</creatorcontrib><creatorcontrib>Yoshida, Eiji</creatorcontrib><creatorcontrib>Suga, Mikio</creatorcontrib><creatorcontrib>Shiraishi, Takahiro</creatorcontrib><creatorcontrib>Tanimoto, Katsuyuki</creatorcontrib><creatorcontrib>Kimura, Yasuyuki</creatorcontrib><creatorcontrib>Obata, Takayuki</creatorcontrib><creatorcontrib>Ito, Hiroshi</creatorcontrib><creatorcontrib>Yamaya, Taiga</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kawaguchi, Hiroshi</au><au>Hirano, Yoshiyuki</au><au>Yoshida, Eiji</au><au>Suga, Mikio</au><au>Shiraishi, Takahiro</au><au>Tanimoto, Katsuyuki</au><au>Kimura, Yasuyuki</au><au>Obata, Takayuki</au><au>Ito, Hiroshi</au><au>Yamaya, Taiga</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source</atitle><btitle>2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)</btitle><stitle>NSSMIC</stitle><date>2013-10</date><risdate>2013</risdate><spage>1</spage><epage>2</epage><pages>1-2</pages><issn>1082-3654</issn><eissn>2577-0829</eissn><eisbn>9781479905348</eisbn><eisbn>9781479905331</eisbn><eisbn>1479905348</eisbn><eisbn>147990533X</eisbn><abstract>Several MRI-based attenuation correction methods have been reported for PET/MRI. The accuracy of the attenuation map (μ-map) from an MRI image depends on correctness of the segmentation of tissue and the attenuation coefficients to be assigned (μ-values). However, an MRI image does not reflect the attenuation of radiation and inaccurate assignment of μ-values affects the quantitative assessment of functional images of PET. Although installation of a transmission scan function on the PET/MRI can provide an accurate μ-map, it restricts the design of the scanner, increases the manufacturing cost and takes additional scanning time. In this study, we implemented an MRI-based μ-value estimation method with a non-rotational radiation source to construct the proper μ-map for PET/MRI and assessed it based on clinical data sets. The proposed method uses the accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position radiation source which usually rotates around the subject to obtain the μ-map with the tomographic procedure. According to the Lambert-Beer law, attenuated intensity is described as the function of partial path length and μ-values of every tissue. The partial path length could be estimated by the simulation of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue could be estimated by inverting the function. The simulation results, based upon measurement data, showed the errors between μ-values of the conventional transmission scan and our proposed method were 2.3±0.9%, 18.6±8.0% and -11.1±5.5% for brain, bone and soft tissue other than brain, respectively. Although there were over- and under-estimations for bone and soft tissue, respectively, the present method is able to estimate the brain μ-value accurately in clinical situations and that strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain.</abstract><pub>IEEE</pub><doi>10.1109/NSSMIC.2013.6829141</doi><tpages>2</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1082-3654
ispartof 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013, p.1-2
issn 1082-3654
2577-0829
language eng
recordid cdi_ieee_primary_6829141
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Attenuation
Biological tissues
Bones
Detectors
Image segmentation
Magnetic resonance imaging
Positron emission tomography
title A MRI-based PET attenuation correction with μ-values measured by a fixed-position radiation source
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T19%3A34%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20MRI-based%20PET%20attenuation%20correction%20with%20%CE%BC-values%20measured%20by%20a%20fixed-position%20radiation%20source&rft.btitle=2013%20IEEE%20Nuclear%20Science%20Symposium%20and%20Medical%20Imaging%20Conference%20(2013%20NSS/MIC)&rft.au=Kawaguchi,%20Hiroshi&rft.date=2013-10&rft.spage=1&rft.epage=2&rft.pages=1-2&rft.issn=1082-3654&rft.eissn=2577-0829&rft_id=info:doi/10.1109/NSSMIC.2013.6829141&rft_dat=%3Cieee_6IE%3E6829141%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=9781479905348&rft.eisbn_list=9781479905331&rft.eisbn_list=1479905348&rft.eisbn_list=147990533X&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6829141&rfr_iscdi=true