Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters

Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics application...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Barrios, Ernesto L., Ursua, Alfredo, Marroyo, Luis, Sanchis, Pablo
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4371
container_issue
container_start_page 4364
container_title
container_volume
creator Barrios, Ernesto L.
Ursua, Alfredo
Marroyo, Luis
Sanchis, Pablo
description Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.
doi_str_mv 10.1109/ECCE.2013.6647284
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6647284</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6647284</ieee_id><sourcerecordid>6647284</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-2f964086d773fa77ec56d024c2a45d1f1a5f345066d89e641c5ab338e98c0e363</originalsourceid><addsrcrecordid>eNo9kM1OAjEUhavRREQewLi5D-Bg_9tZkgmICUYXypbU6a2plBnSmaDy9GIkrr5zNl9yDiHXjI4Zo-XdtKqmY06ZGGstDbfyhFwyacqSCqHZKRlwwctCGGnP_jNnF2TUdR-UUqYtt5QNSHpsPaYUm_dbiJttbne4waYH13jAry3m-Ftdgp1L0bs-tg20ARwoCuv5vlCwXk4gxX5ffMaMHvrsmi60eYMZDoDnJcRmh7nH3F2R8-BSh6Mjh-R1Nn2p5sXi6f6hmiyKyIzqCx5KLanV3hgRnDFYK-0plzV3UnkWmFNBSEW19rZELVmt3JsQFktbUxRaDMnNnzci4mp72ODy9-p4lPgBxKdaQA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</creator><creatorcontrib>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</creatorcontrib><description>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</description><identifier>ISSN: 2329-3721</identifier><identifier>EISSN: 2329-3748</identifier><identifier>EISBN: 1479903361</identifier><identifier>EISBN: 9781479903368</identifier><identifier>DOI: 10.1109/ECCE.2013.6647284</identifier><language>eng</language><publisher>IEEE</publisher><subject>Conductors ; Core loss ; Loss measurement ; Power transformers ; Temperature measurement ; Windings ; Wires</subject><ispartof>2013 IEEE Energy Conversion Congress and Exposition, 2013, p.4364-4371</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6647284$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6647284$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Barrios, Ernesto L.</creatorcontrib><creatorcontrib>Ursua, Alfredo</creatorcontrib><creatorcontrib>Marroyo, Luis</creatorcontrib><creatorcontrib>Sanchis, Pablo</creatorcontrib><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><title>2013 IEEE Energy Conversion Congress and Exposition</title><addtitle>ECCE</addtitle><description>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</description><subject>Conductors</subject><subject>Core loss</subject><subject>Loss measurement</subject><subject>Power transformers</subject><subject>Temperature measurement</subject><subject>Windings</subject><subject>Wires</subject><issn>2329-3721</issn><issn>2329-3748</issn><isbn>1479903361</isbn><isbn>9781479903368</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kM1OAjEUhavRREQewLi5D-Bg_9tZkgmICUYXypbU6a2plBnSmaDy9GIkrr5zNl9yDiHXjI4Zo-XdtKqmY06ZGGstDbfyhFwyacqSCqHZKRlwwctCGGnP_jNnF2TUdR-UUqYtt5QNSHpsPaYUm_dbiJttbne4waYH13jAry3m-Ftdgp1L0bs-tg20ARwoCuv5vlCwXk4gxX5ffMaMHvrsmi60eYMZDoDnJcRmh7nH3F2R8-BSh6Mjh-R1Nn2p5sXi6f6hmiyKyIzqCx5KLanV3hgRnDFYK-0plzV3UnkWmFNBSEW19rZELVmt3JsQFktbUxRaDMnNnzci4mp72ODy9-p4lPgBxKdaQA</recordid><startdate>201309</startdate><enddate>201309</enddate><creator>Barrios, Ernesto L.</creator><creator>Ursua, Alfredo</creator><creator>Marroyo, Luis</creator><creator>Sanchis, Pablo</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201309</creationdate><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><author>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-2f964086d773fa77ec56d024c2a45d1f1a5f345066d89e641c5ab338e98c0e363</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Conductors</topic><topic>Core loss</topic><topic>Loss measurement</topic><topic>Power transformers</topic><topic>Temperature measurement</topic><topic>Windings</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Barrios, Ernesto L.</creatorcontrib><creatorcontrib>Ursua, Alfredo</creatorcontrib><creatorcontrib>Marroyo, Luis</creatorcontrib><creatorcontrib>Sanchis, Pablo</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore (IEEE/IET Electronic Library - IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Barrios, Ernesto L.</au><au>Ursua, Alfredo</au><au>Marroyo, Luis</au><au>Sanchis, Pablo</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</atitle><btitle>2013 IEEE Energy Conversion Congress and Exposition</btitle><stitle>ECCE</stitle><date>2013-09</date><risdate>2013</risdate><spage>4364</spage><epage>4371</epage><pages>4364-4371</pages><issn>2329-3721</issn><eissn>2329-3748</eissn><eisbn>1479903361</eisbn><eisbn>9781479903368</eisbn><abstract>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</abstract><pub>IEEE</pub><doi>10.1109/ECCE.2013.6647284</doi><tpages>8</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 2329-3721
ispartof 2013 IEEE Energy Conversion Congress and Exposition, 2013, p.4364-4371
issn 2329-3721
2329-3748
language eng
recordid cdi_ieee_primary_6647284
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Conductors
Core loss
Loss measurement
Power transformers
Temperature measurement
Windings
Wires
title Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T16%3A08%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Modelling,%20improvement%20and%20experimental%20validation%20of%20a%2050%20kHz-5%20kVA%20litz-wired%20transformer%20for%20PV%20inverters&rft.btitle=2013%20IEEE%20Energy%20Conversion%20Congress%20and%20Exposition&rft.au=Barrios,%20Ernesto%20L.&rft.date=2013-09&rft.spage=4364&rft.epage=4371&rft.pages=4364-4371&rft.issn=2329-3721&rft.eissn=2329-3748&rft_id=info:doi/10.1109/ECCE.2013.6647284&rft_dat=%3Cieee_6IE%3E6647284%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1479903361&rft.eisbn_list=9781479903368&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6647284&rfr_iscdi=true