Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters
Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics application...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4371 |
---|---|
container_issue | |
container_start_page | 4364 |
container_title | |
container_volume | |
creator | Barrios, Ernesto L. Ursua, Alfredo Marroyo, Luis Sanchis, Pablo |
description | Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels. |
doi_str_mv | 10.1109/ECCE.2013.6647284 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_6647284</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6647284</ieee_id><sourcerecordid>6647284</sourcerecordid><originalsourceid>FETCH-LOGICAL-i175t-2f964086d773fa77ec56d024c2a45d1f1a5f345066d89e641c5ab338e98c0e363</originalsourceid><addsrcrecordid>eNo9kM1OAjEUhavRREQewLi5D-Bg_9tZkgmICUYXypbU6a2plBnSmaDy9GIkrr5zNl9yDiHXjI4Zo-XdtKqmY06ZGGstDbfyhFwyacqSCqHZKRlwwctCGGnP_jNnF2TUdR-UUqYtt5QNSHpsPaYUm_dbiJttbne4waYH13jAry3m-Ftdgp1L0bs-tg20ARwoCuv5vlCwXk4gxX5ffMaMHvrsmi60eYMZDoDnJcRmh7nH3F2R8-BSh6Mjh-R1Nn2p5sXi6f6hmiyKyIzqCx5KLanV3hgRnDFYK-0plzV3UnkWmFNBSEW19rZELVmt3JsQFktbUxRaDMnNnzci4mp72ODy9-p4lPgBxKdaQA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</creator><creatorcontrib>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</creatorcontrib><description>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</description><identifier>ISSN: 2329-3721</identifier><identifier>EISSN: 2329-3748</identifier><identifier>EISBN: 1479903361</identifier><identifier>EISBN: 9781479903368</identifier><identifier>DOI: 10.1109/ECCE.2013.6647284</identifier><language>eng</language><publisher>IEEE</publisher><subject>Conductors ; Core loss ; Loss measurement ; Power transformers ; Temperature measurement ; Windings ; Wires</subject><ispartof>2013 IEEE Energy Conversion Congress and Exposition, 2013, p.4364-4371</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6647284$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2058,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6647284$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Barrios, Ernesto L.</creatorcontrib><creatorcontrib>Ursua, Alfredo</creatorcontrib><creatorcontrib>Marroyo, Luis</creatorcontrib><creatorcontrib>Sanchis, Pablo</creatorcontrib><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><title>2013 IEEE Energy Conversion Congress and Exposition</title><addtitle>ECCE</addtitle><description>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</description><subject>Conductors</subject><subject>Core loss</subject><subject>Loss measurement</subject><subject>Power transformers</subject><subject>Temperature measurement</subject><subject>Windings</subject><subject>Wires</subject><issn>2329-3721</issn><issn>2329-3748</issn><isbn>1479903361</isbn><isbn>9781479903368</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2013</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNo9kM1OAjEUhavRREQewLi5D-Bg_9tZkgmICUYXypbU6a2plBnSmaDy9GIkrr5zNl9yDiHXjI4Zo-XdtKqmY06ZGGstDbfyhFwyacqSCqHZKRlwwctCGGnP_jNnF2TUdR-UUqYtt5QNSHpsPaYUm_dbiJttbne4waYH13jAry3m-Ftdgp1L0bs-tg20ARwoCuv5vlCwXk4gxX5ffMaMHvrsmi60eYMZDoDnJcRmh7nH3F2R8-BSh6Mjh-R1Nn2p5sXi6f6hmiyKyIzqCx5KLanV3hgRnDFYK-0plzV3UnkWmFNBSEW19rZELVmt3JsQFktbUxRaDMnNnzci4mp72ODy9-p4lPgBxKdaQA</recordid><startdate>201309</startdate><enddate>201309</enddate><creator>Barrios, Ernesto L.</creator><creator>Ursua, Alfredo</creator><creator>Marroyo, Luis</creator><creator>Sanchis, Pablo</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>201309</creationdate><title>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</title><author>Barrios, Ernesto L. ; Ursua, Alfredo ; Marroyo, Luis ; Sanchis, Pablo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i175t-2f964086d773fa77ec56d024c2a45d1f1a5f345066d89e641c5ab338e98c0e363</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Conductors</topic><topic>Core loss</topic><topic>Loss measurement</topic><topic>Power transformers</topic><topic>Temperature measurement</topic><topic>Windings</topic><topic>Wires</topic><toplevel>online_resources</toplevel><creatorcontrib>Barrios, Ernesto L.</creatorcontrib><creatorcontrib>Ursua, Alfredo</creatorcontrib><creatorcontrib>Marroyo, Luis</creatorcontrib><creatorcontrib>Sanchis, Pablo</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore (IEEE/IET Electronic Library - IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Barrios, Ernesto L.</au><au>Ursua, Alfredo</au><au>Marroyo, Luis</au><au>Sanchis, Pablo</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters</atitle><btitle>2013 IEEE Energy Conversion Congress and Exposition</btitle><stitle>ECCE</stitle><date>2013-09</date><risdate>2013</risdate><spage>4364</spage><epage>4371</epage><pages>4364-4371</pages><issn>2329-3721</issn><eissn>2329-3748</eissn><eisbn>1479903361</eisbn><eisbn>9781479903368</eisbn><abstract>Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.</abstract><pub>IEEE</pub><doi>10.1109/ECCE.2013.6647284</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 2329-3721 |
ispartof | 2013 IEEE Energy Conversion Congress and Exposition, 2013, p.4364-4371 |
issn | 2329-3721 2329-3748 |
language | eng |
recordid | cdi_ieee_primary_6647284 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Conductors Core loss Loss measurement Power transformers Temperature measurement Windings Wires |
title | Modelling, improvement and experimental validation of a 50 kHz-5 kVA litz-wired transformer for PV inverters |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T16%3A08%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Modelling,%20improvement%20and%20experimental%20validation%20of%20a%2050%20kHz-5%20kVA%20litz-wired%20transformer%20for%20PV%20inverters&rft.btitle=2013%20IEEE%20Energy%20Conversion%20Congress%20and%20Exposition&rft.au=Barrios,%20Ernesto%20L.&rft.date=2013-09&rft.spage=4364&rft.epage=4371&rft.pages=4364-4371&rft.issn=2329-3721&rft.eissn=2329-3748&rft_id=info:doi/10.1109/ECCE.2013.6647284&rft_dat=%3Cieee_6IE%3E6647284%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1479903361&rft.eisbn_list=9781479903368&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6647284&rfr_iscdi=true |